Joseph Doherty 5db01053e8 docs(redundancy): stop claiming RedundancySupport/ServerUriArray are exposed; record why #717 is blocked (lmxopcua#717)
v2-ci / unit-tests (push) Waiting to run
Bounded, docs-only part of #717. The standard non-transparent metadata itself is
NOT implemented here: the owner-selected contract is Warm with an explicit
degraded standby (and None standalone), today's Secondary serves Good data at
ServiceLevel 240, and the design/spec/plan for that standby behaviour is still
pending on the issue - advertising Warm now would misdescribe the server.

- docs/Redundancy.md: the "deferred pending an SDK object-type upgrade" claim
  was wrong; the pinned SDK 1.5.378.106 can build the graph
  (CreateMainNodeManagerFactory + AddBehaviourToPredefinedNode). Records what is
  and is not advertised (i=3709 SDK default, no i=11314) and the blocker.
- .claude/rules/cluster-topology.md: said each node exposes RedundancySupport
  and ServerUriArray; it does not.
- docs/OpcUaServer.md: same false claim about the SDK exposing them.

Interop gates A4/A5b stay unmet; no product code changed.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 13:12:17 -05:00
Joseph Doherty acfb4fbaca fix(redundancy): a failed OPC UA endpoint drops ServiceLevel to 0 and steps the Primary down (lmxopcua#762)
v2-ci / unit-tests (push) Has been cancelled
IOpcUaEndpointState (review-remediation lane C3) recorded whether the SDK started, but only the
health check read it: a fused node whose endpoint failed (port 4840 taken, ...) still advertised
250/240 and stayed driver Primary, so the Primary-gated data plane ran on a node no client could
reach while the reachable peer refused writes as Secondary.

- Move IOpcUaEndpointState/OpcUaEndpointState/OpcUaEndpointStatus from Host to Commons.OpcUa so
  the Runtime can consume it.
- ServiceLevelCalculator: new NodeHealthInputs.EndpointListening (default true). false -> 0,
  ahead of every other input including the +10 Primary bonus.
- OpcUaPublishActor: takes the endpoint state, feeds EndpointListening (Failed only; NotStarted /
  Stopped are boot/shutdown windows) on the DB-backed and DB-less paths, and the legacy role-only
  seam returns 0 for a failed endpoint too.
- New OpcUaEndpointStepDownActor (one per driver node): a Primary (ClusterActiveNode.SelfIsActive,
  the election's own primitive) with a Failed endpoint gracefully Leaves its mesh - the manual
  failover mechanism - so the peer becomes the oldest Up driver member, hosts the singletons and is
  Primary. The election itself is not bent. Guarded on a peer having recently reported its own
  endpoint listening (EndpointReport on the new opcua-endpoint-state DPS topic), so a pair with
  both endpoints failed does not bounce the role and restart nodes forever, and a lone node never
  shuts itself down.
- Runtime now references ZB.MOM.WW.Health.Akka (ClusterActiveNode).
- Docs: Redundancy.md tier table + new "Endpoint start failure: Primary step-down" section;
  cluster-topology rule; HealthEndpoints / OpcUaEndpointHealthCheck comments (F-C1 landed).

Tests: ServiceLevelCalculatorTests (+5), OpcUaPublishActorEndpointStateTests (7: DB-less,
DB-backed, legacy seam, NotStarted/Stopped do not demote, a later failure demotes on the next
tick), OpcUaEndpointStepDownActorTests (3, real two-node mesh: holds while the peer is not
listening then leaves and the peer becomes Primary; failed Secondary and healthy Primary never
leave). Each was mutation-checked: removing the calculator/legacy guard, the Leave, the
peer-listening guard or the Primary guard fails the corresponding tests.
2026-11-09 12:16:37 -05:00
Joseph Doherty 8c6067b62e docs: move subsystem gotchas out of CLAUDE.md into path-scoped .claude/rules
Keeps the root CLAUDE.md lean by lazy-loading per-area detail (drivers, topology,