The cross-version matrix (#782) used a 55-char 'otua_matrix_' key, which stayed under
SDK 2's 64-byte RsaEncryptedSecret threshold and hid #880. It now uses the
ApiKeySecret.Generate shape (65 chars, random per run, never recorded). Every Shared
leg adds production-length-API-key-wrong-secret-reaches-key-check, which must get
BadIdentityTokenRejected rather than a format failure. SDK 2 clients also add
sdk2-default-RsaEncryptedSecret-control, the negative control: the SDK's default
handler must be refused with BadIdentityTokenInvalid by a 1.x server and admitted
by an SDK 2 server. The runner passes the server SDK version from ready.json.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
SDK 2.0.1's UserNameIdentityTokenHandler encrypts a password longer than 64 bytes
(a private RsaEncryptedSecretPasswordThreshold, no setting) as an RsaEncryptedSecret
with EncryptionAlgorithm=null. SDK 1.5.378 (.106 and .182) decrypts only the legacy
format under RSA policies; its SecurityPolicies.Decrypt answers a null algorithm with
BadIdentityTokenInvalid ("Unexpected encryption algorithm") before any key check.
Every production API key is 65 chars, so no SDK 2 OtOpcUa client could use one
against QA (b8b4c18f), a rollback target or an older third-party server.
LegacyRsaUserNameIdentityTokenHandler (Driver.OpcUaClient.Session, plugged in through
the public UserIdentity(IUserIdentityTokenHandler) ctor) always uses the legacy
format, RSA-OAEP(len|password|serverNonce) under the server certificate, under an RSA
policy. That is what SDK 2 sends for passwords of 64 bytes or less and what SDK 1.5
clients always send. The legacy format has no size limit (the plaintext is
length-framed over as many RSA blocks as it needs), and an SDK 2 server reads both
formats. Policy None, the ECC policies and a missing certificate go to the SDK
handler unchanged.
OpcUaUserIdentityFactory.UserName is now the one UserName identity the driver, the
AdminUI browse and Client.Shared (CLI/UI) present. Client.Shared references .Session
for it.
Tests: handler unit tests (all three RSA policies, the 1.5-required algorithm URI,
SDK 2 server-side decrypt, the session Copy() keeps the type, None unchanged, and an
SDK control pinning the 64/65-byte switch); a Client.Shared identity test; and an
SDK2<->SDK2 integration test where a 65-char key is admitted in both formats and a
wrong 65-char key reaches the key check (BadIdentityTokenRejected). The #800 Windows
gate's SDK 2 CLI 65-char case now gates against the 1.5 server too.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Adds scripts/validation/opcua-windows-service/: a phased PowerShell gate (Invoke-ServiceGate.ps1)
that installs the known-good build as the real OtOpcUaHost service via Install-Services.ps1, seeds
LocalDb through the production cache API (Seeder, built against the baseline tree), upgrades in
place with config/PKI/LocalDb carried with their ACLs, starts/stops through the SCM, runs a strict
SDK 2 probe matrix (Sign + SignAndEncrypt, valid/wrong/unknown/disabled/anonymous keys, untrusted
client and server), exercises the ScriptWorker isolation, rolls back and cleans up.
windev 2026-11-12 (efb9197a -> 438484fd -> efb9197a): app cert CEF9D91F... reused byte-for-byte
with identical PKI SDDL on every start, all gating checks pass, 0 secrets in logs. Findings filed:
#879 (None endpoint cannot be dropped), #880 (SDK 2 client 65-char key vs SDK 1.5 server:
rollback/QA risk), #883 (Install-ScriptWorkerIsolation.ps1 fails on pwsh 7 and 5.1; runtime
isolation proven with the patch in the evidence directory).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Console helper that mints and revokes OPC UA API keys through the same IApiKeyAdminService the AdminUI
/apikeys page calls, edits NodeAcl grants in the rig ConfigDb, and holds one OPC UA session open per node
(Client.Shared) with a subscription plus a read/write every 3 s, so a revocation, expiry or grant removal
can be observed landing on an ALREADY-OPEN session on both pair nodes next to a non-revoked control key.
Credentials go to a 0600 file and are never printed. LOCAL docker-dev only.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
AvevaGatewayHistoryLiveGateTests boots the server in-process, wires the production
Gateway backend (HistorianBackendRegistry -> GatewayHistorianDataSource) to a real
HistorianGateway and drives HistoryRead over a real SDK session: raw (all, paged,
reverse, bounds), modified, the ten served aggregates and seven refused ones, AtTime,
events (all, 1-event pages, reverse), a missing tag, HistoryServerCapabilities and
node metadata, and a HistoryUpdate that must be refused (sandbox-bound node only).
Every wire answer is compared with the backend's direct answer; the run is dumped as
JSON for cross-SDK and SQL comparison. Skips unless HISTGW_GATEWAY_ENDPOINT and
HISTGW_GATEWAY_APIKEY are set; read-only by construction.
scripts/validation/aveva-history-801: run/compare instructions, the SDK 1.5.378
baseline port patch (API spelling only), and the diff / SQL / aggregate / histgw-cli
comparison scripts.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Probe 'failover <primary> <backup> <mode> <dir>' drives ScadaBridge's own DataConnectionActor
(production primary/backup machine, real DataConnectionFactory, default DataConnectionOptions,
FailoverRetryCount 3) against two servers; run.py loses the primary (SIGKILL or SIGSTOP) once the
probe reports a steady primary, and the probe requires Bad quality on loss, "Connected to backup",
the backup's own value, a fresh ConditionRefresh replaying the native condition, and a write via the
backup. rig-failover.sh runs the same probe against the local docker-dev central pair.
Matrix legs gain a UNS subscription case and a Server-object alarm subscription on the reconnected
session whose ConditionRefresh must replay the active condition (11 cases). run.py gains --versions,
--suites, --failover-modes and --failover-loss.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Probe 'prepare' provisions the consumer identity via OpcUaApplicationIdentity.EnsureApplicationCertificateAsync
and exports the public DER; runner installs it in the server trusted store before start. Adds Sign
(OPCUA_MATRIX_SERVER_SECURITY=sign), untrusted-client / untrusted-server fail-closed controls per secure
mode, and OPCUA_MATRIX_ACL=off. Autoaccept stays false everywhere.
Hosted v2-integration run 1224 got past the old fixture-host timeout and
failed one step earlier: "Bind for :::19000 failed: port is already
allocated" — the runner's docker daemon is shared. Fixtures now retry on the
next host port when one is taken (opc-plc keeps host == listen port, as its
advertised endpoint requires) and export the ports actually used; container
names carry the run id so a concurrent run's `down` can't remove them, and a
new `logs` subcommand replaces the workflow's hard-coded name list.
Verified locally: with 19000 squatted, QuestDB moved to 18813/19001 and every
fixture reached ready; logs/down found the suffixed containers.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Read-only ConfigDb preflight (scripts/preflight/vd03-preupgrade-b8b4c18f-configdb-checks.sql)
covering every deploy gate added since the deployed build: VirtualTag/Calculation effective
triggers (#783), VT->VT reads and VirtualTagDependencyCycle (#791), newly forbidden script
APIs (#792, E2), credential-reference namespace / other-instance / reserved-name rules
(#815#835#836#848#849#850), MTConnectMultipleDevices, Sql query/write gates (#781),
Heidenhain, UNS effective-name collisions and the FOCAS renames/value changes. Verified on a
throwaway b8b4c18f-schema database (every check fires on seeded rows) and clean against the
docker-dev config.
Upgrade notes (docs/deploy/vd03-upgrade-b8b4c18f-to-master.md): the EnableSnapshotIsolation
migration and how to apply it by hand, the env-var audit (Security:ApiKeys:Pepper is now
required and absent on the box; JWT key validated at start), SDK 2.0.1 / CA KeyUsage, the
ScadaBridge-visible changes, swap/rollback and post-deploy checks.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
catthehacker/ubuntu:act-latest ships no iproute2, so fixture_host() fell back to 127.0.0.1 inside the
job container and every published-port fixture timed out (QuestDB is the first one probed over the
network). Read the default gateway from /proc/net/route in plain bash, warn when none is found, and log
the chosen host. Verified in that image on a user-defined network: gateway parsed, published port 200.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
The persistent NAT PKI (ae91e6b7) re-verified 2026-11-11: same thumbprint
1FBF8791... across --force-recreate on 10.100.0.35, matching the committed
opc-plc-nat-server.der; NAT class 7/7 against the shared stack and against a
CI-style throwaway container + docker-exec cert hand-off. MIN_EXECUTED stays
at 440: no hosted v2-integration run has reached the test step (#860).
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Decision: CI stays hermetic (no dependency on the 10.100.0.35 box or its
state), but must run the same engine. integration-fixtures.sh now takes the
questdb/questdb:<tag> line from the #822 fixture compose file (10.0.1 today,
same as the docker-dev overlay) and fails 'up' if it is missing;
CI_QDB_IMAGE overrides for a trial. Documented in scripts/ci/README.md.
Co-Authored-By: Claude <noreply@anthropic.com>
#816 finding: the SDK checks that the server certificate names the host only
when a session is created with checkDomain:true. The driver, the AdminUI
browser and Client.Shared all called the 8-argument
DefaultSessionFactory.CreateAsync, which forwards checkDomain:false — so no
host-name check ever ran (why a trusted NAT cert for *.invalid browsed fine
over an IP in #813). When enabled the SDK (Session.OpenAsync ->
ValidateDomains -> FindDomain) compares ConfiguredEndpoint.EndpointUrl.IdnHost
— the CONFIGURED host, because OpcUaEndpointSelection/EndpointSelector
rewrote the advertised one — against the cert's DNS/IP SANs; secured
sessions only, and the auto-accept handler accepts a mismatch.
Policy: certificateValidation.validateServerHostName, tri-state. Unset =
OpcUaCertificateValidationOptions.DefaultValidateServerHostName = false, the
pre-#816 behaviour, so nothing changes on upgrade; true = validate the
configured host; false = explicit NAT/port-publish opt-out. Threaded into the
driver, the AdminUI browser (same JSON) and the AdminUI form (a select that
keeps "unset" unset), Client.Shared ConnectionSettings.ValidateServerHostName
and the CLI --validate-host-name. A driver refusal names the opt-out.
#818: the NAT fixture's /app/pki is on the opc-plc-nat-pki volume (verified:
same thumbprint across --force-recreate), its PUBLIC cert is committed as
Docker/nat/opc-plc-nat-server.der, and NatPublishedEndpointBrowseTests run
every secure browse on a throwaway PKI (internal browser seam): refusal with
nothing trusted, positive with the cert trusted (unset/false host check), and
a BadCertificateHostNameInvalid refusal with the check on. The trusted cert is
OPCUA_NAT_SERVER_CERT or the committed one (skip on thumbprint mismatch);
OPCUA_NAT_SERVER_CERT_TRUSTED is retired. CI exports its throwaway NAT
container's public cert. ServerHostNameValidationTests pin the driver against
the plain opc-plc. MIN_EXECUTED not raised (needs a hosted run): +6 in
v2-integration (440 -> 446), documented in scripts/ci/README.md.
Docker/nat/docker-compose.yml (stack /opt/otopcua-opcuaclient-nat on 10.100.0.35,
project: lmxopcua label): opc-plc 2.14.10 advertising --ph=otopcua-opc-plc-nat-private.invalid
on internal 50000, published on 50010, so every advertised URL is unreachable on host AND
port. Deployed; NatPublishedEndpointBrowseTests 3/3 against opc.tcp://10.100.0.35:50010
(and the secure case positive once, with the fixture cert temporarily trusted).
CI: integration-fixtures.sh starts a throwaway otopcua-ci-opcplc-nat (50110->50000) and
exports OPCUA_NAT_ENDPOINT; v2-e2e.yml points it at the shared stack. infra/README.md,
scripts/ci/README.md and the fixture README document it.
Scripted condition NodeIds are opaque ScriptedAlarmIds, so splitting them as a
topology path could never match an Equipment grant: a narrow equipment grant was
denied while a Cluster grant passed.
- OtOpcUaNodeManager binds each LIVE scripted condition instance to the
EquipmentId it was materialised under (only when it hangs under that folder);
dropped on remove / drop-recreate / equipment-subtree removal / rebuild; a
same-id re-materialise under another equipment re-parents and re-binds.
- DataPlaneAuthoritySnapshot carries EquipmentScopePaths (EquipmentId ->
[uns, Area, Line, Equipment]) decoded from the artifact by the same
AclScopePathResolver call that plants Equipment grants.
- DataPlaneAuthorizer.AuthorizeScriptedCondition re-reads key, grant and
generation per call (uncached) and evaluates at the owner path; unbound,
replaced or unplaceable owners deny under every grant. No id-split or
realm-root fallback.
- Native conditions (RawPath) and the ACL-off role gate are unchanged.
NodeIds and AlarmCommand.AlarmId are unchanged.
Sdk2OpaqueScriptedScopeBaselineTests deliberately flipped: it pinned the denial
and now pins owner-grant allow / sibling deny / cluster allow. Follow-up #808
(folder ids + Server-object event visibility for narrow UNS grants).