3 Commits

Author SHA1 Message Date
Joseph Doherty 94926eb0d7 ci: fixture-backed integration workflow and guarded fleet E2E workflow (lmxopcua#757)
v2-ci / unit-tests (push) Has been cancelled
v2-integration.yml runs the Sql, Historian.SqlServer, Historian.QuestDb and OpcUaClient
integration projects against throwaway SQL Server/PostgreSQL/QuestDB/opc-plc containers
started by scripts/ci/integration-fixtures.sh, with a MIN_EXECUTED=440 floor. v2-e2e.yml is
manual/weekly, probes the shared fleet and skips cleanly when unreachable. v2-ci.yml is
functionally unchanged. Unverified on a hosted runner until first run.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 16:53:44 -05:00
Joseph Doherty 67de2c942b ci(r2-12): delete no-op nightly E2E workflow + redundant integration matrix (07/S-3, 07/P-5)
- v2-e2e.yml deleted: its `--filter Category=E2E` matches zero tests repo-wide (the
  E2ETests project doesn't exist) so it reported a permanent false green; and its
  docker-dev fleet binds the LAN-only shared GLAuth (10.100.0.35:3893) + builds local
  images, so it isn't hosted-runner-bootable anyway. FOLLOW-UP: when a runner-reachable
  fleet + a real tests/Server/...E2ETests land, add a fresh workflow WITH a zero-match
  guard (fail if Category=E2E matches nothing).
- v2-ci.yml integration matrix removed: fully redundant with the unit-tests leg, which
  already runs both Host.IntegrationTests + OpcUaServer.IntegrationTests under the
  identical filter, fixtureless, gated at MIN_EXECUTED=1. No coverage lost. The S-2
  option-#2 fixture-backed-leg follow-up is preserved as a NOTE comment in the workflow.
Header comments updated; YAML validates; jobs are now build -> unit-tests.
2026-07-13 09:54:22 -04:00
Joseph Doherty 253fb60459 ci: v2 build + unit + integration workflow, nightly E2E (Task 61)
.github/workflows/v2-ci.yml runs on push/PR to v2-akka-fuse + master:
  - build job: dotnet restore + build (Release)
  - unit-tests job: matrix over the 5 v2 test projects (Cluster, ControlPlane,
    Runtime, Security, OpcUaServer) with Category!=E2E
  - integration job: Host.IntegrationTests with Category!=E2E

.github/workflows/v2-e2e.yml runs nightly at 03:00 UTC + workflow_dispatch:
  - Brings up the docker-dev four-node fleet (admin pair + driver pair + SQL
    + LDAP + Traefik)
  - Waits up to 60s for /health/active to return 200
  - Runs Category=E2E only
  - Always tears down with -v

Both workflows pin .NET 10 via actions/setup-dotnet (no global.json so any
10.0 SDK works). Compatible with both GitHub Actions and Gitea Actions
(act_runner). The E2E filter currently matches zero tests because the
tests/Server/ZB.MOM.WW.OtOpcUa.E2ETests project doesn't exist yet — it lands
when F10/F11/F12 wire enough engine for an end-to-end round-trip to be
meaningful.
2026-05-26 06:48:52 -04:00