cf9ce91e51 |
test(mtconnect): live-Agent docker fixture + integration suite (Tasks 19+20)
The first and only thing in the MTConnect workstream that exercises the driver
against a real Agent; everything else runs on canned XML.
Fixture (Docker/): two services, both stock images with this folder bind-mounted.
- `agent` mtconnect/agent:2.7.0.12 on :5000. NOTE the repo name: the source
project is mtconnect/cppagent but the PUBLISHED image is
mtconnect/agent; mtconnect/cppagent does not exist on Docker Hub.
- `adapter` a stdlib SHDR feeder. Required, not optional: the agent image ships
only the binary + schemas/styles, so a lone Agent answers /probe and
then reports every observation UNAVAILABLE forever, which can prove
nothing about reads or streaming.
Devices.xml seeds one DataItem per inference branch (SAMPLE+units, TIME_SERIES,
PART_COUNT/LINE_NUMBER, controlled vocab, DATA_SET, CONDITION), gives every named
item `name != id` (the inverse of the hand-authored unit fixtures), and leaves one
EVENT permanently unfed so UNAVAILABLE -> BadNoCommunication has a live subject.
Suite (12 tests) asserts STRUCTURALLY against the Agent's own /probe response, never
by literal id, so it survives an edit to Devices.xml and can be pointed at a real
machine tool via MTCONNECT_AGENT_ENDPOINT. It skips cleanly (12/12) when no Agent
answers, and each test carries a hard [Fact(Timeout)] so a half-up fixture cannot
wedge a build.
Three findings from bringing the fixture up, each now pinned in a comment:
- agent.cfg must be pure ASCII; one non-ASCII byte in a COMMENT makes the config
parser reject the whole file with a bare "Failed / Stopped at line: N" and exit.
- `sampleCount` is an attribute of a TIME_SERIES observation, not of a DataItem
declaration. A real Agent meeting one on a declaration DROPS THE ENTIRE DATA ITEM
from the device model, so the inference only ever sees null and a live TIME_SERIES
tag is always variable-length. Asserted, not ignored.
- The Agent's own <Agent> self-model publishes update-rate SAMPLEs that tick whether
or not any adapter is attached. Excluding them is load-bearing: with them included
the "live stream delivered a changed value" test passed with the fixture's data
source deliberately stopped.
MTConnectError-under-HTTP-200 is NOT covered live and cannot be: cppagent 2.7 answers
an unknown device 404 and an out-of-range sequence 400, each with a well-formed error
body. That shape stays canned-only, and the suite says so.
|
||
|
|
d5bd4226ee |
docs(mqtt): Sparkplug P2 live-verified; MQTT driver complete
Task 26 — the P2 milestone gate. Ran the live /run verification on an isolated
docker-dev rig (project otopcua-mqtt, ports 9210/4850-4851/14350, image built
from this branch) against the real Mosquitto TLS+auth broker and the C#
Sparkplug edge-node simulator on 10.100.0.35, and recorded the result.
The gate found three defects. Two are the same defect class the P1 gate found
twice — a hand-maintained AdminUI surface left behind by a driver-side feature —
and the third is a pre-existing cross-driver bug that only a Sparkplug flow
could surface.
1. CRITICAL, FIXED — MqttDriverForm still shipped its P1 Sparkplug PLACEHOLDER.
Switching Mode to SparkplugB rendered a "not available yet" notice and NO
Group ID field, so with Sparkplug ingest fully shipped there was still no
way to author a Sparkplug driver from the AdminUI at all. Sparkplug.GroupId
is the driver's entire subscription filter (spBv1.0/{GroupId}/#): blank ⇒
connected, Healthy, ingesting nothing. Now authors all five Sparkplug keys,
MERGES over the existing sub-object rather than replacing it (so a key a
newer driver adds inside it survives an older AdminUI), leaves it untouched
in Plain mode, and validates the group id as the topic segment it is.
Pinned by 8 MqttDriverFormModelTests cases, verified falsifiable — 8 RED
with the fix stubbed out.
2. PRE-EXISTING + CROSS-DRIVER, FIXED — every node label in the shared
DriverBrowseTree was an <a href="#">. In a Blazor Web App, blazor.web.js's
enhanced-navigation click interceptor resolves a bare "#" against
<base href="/">, so clicking ANY browse-tree node label navigated the whole
AdminUI to "/", tore down the circuit, and destroyed the hosting modal —
losing the browse session AND the tag selection. @onclick:preventDefault
does not help: it suppresses the browser's default action, not Blazor's own
interceptor. Labels are now <button type="button">. Dates to the component's
introduction (2026-05-28) and affects EVERY driver's picker; it surfaced
only now because choosing a rebirth scope is the first flow that requires
clicking a label rather than the ▶ toggle (always a button, always fine).
3. FIXED (mitigation) — the browse tree rendered exactly once, at open, and
never again, while OpenAsync returns as soon as the SUBSCRIBE is granted.
On Sparkplug that means it is almost always empty forever, because births
are never retained. Added a Refresh button that re-reads the root against
the SAME session (nothing reconnects, nothing observed is lost, the tag
selection is kept, only the armed rebirth scope is cleared).
Live gate result (all against the real broker + simulator, group OtOpcUaSim):
- driver authored end-to-end through the fixed MqttDriverForm; blob is
Mode:SparkplugB + Sparkplug.GroupId:OtOpcUaSim with enums as names
- browse: BROWSER OPEN chip, Sparkplug-only rebirth panel, tree renders
Group → EdgeNode → [Device] → Metric with the device folder Filler1 and
node-level metric leaves SIDE BY SIDE, and "Node Control/Rebirth" as ONE
leaf (the metric-name-is-not-a-topic-segment rule holding)
- rebirth: group scope names the group + the 32-node cap, Cancel published
NOTHING (simulator log unchanged); edge-node scope → "1 command published"
and the simulator logged "rebirth NCMD #1 received; republishing metadata";
group scope → "2 commands published", both edge nodes re-birthed; a device
and a metric both resolve UP to "edge node EdgeA"; the panel does NOT render
for a Plain MQTT device
- browse-commit wrote bindable tuples with no topic/address key —
{"groupId","edgeNodeId","metricName","deviceId"} for the device metric and
deviceId ABSENT (not blank) for the node-level one, datatypes inherited from
the birth (Int64 / Float)
- deployed (Sealed), and both nodes served live changing values through OPC UA
at the 2 s cadence — Good 0x00000000, no BadNodeIdUnknown
- death→STALE: stopping the simulator drove both nodes to 0x80000000 with an
empty value ~2 s later, and restarting it recovered them to Good on the new
birth (FillCount back to its birth-declared 1000, then counting)
- rediscovery fired exactly TWICE (once per authored scope: OtOpcUaSim/EdgeA
7 metrics, OtOpcUaSim/EdgeA/Filler1 3 metrics) and was then gated across
many subsequent births/rebirths — the anti-storm change gate working, and
EdgeB correctly filtered out as an unauthored scope
- tag editor: opens in SparkplugB (mode inference on reopen) with all four
descriptor fields populated; blank group → "A Sparkplug group ID is
required."; "Plant/1" rejected; "Node Control/Rebirth" ACCEPTED and saved
with the slash whole; dataType override persists and its key is ABSENT again
after selecting "(from birth certificate)"
Two things are NOT verified, and are recorded rather than claimed:
- Rediscovery is INERT in v3 and this is a platform gap, not an MQTT one:
nothing subscribes to IRediscoverable.OnRediscoveryNeeded and
DriverHostActor.HandleDiscoveredNodes hard-returns. A DBIRTH introducing a
metric does NOT change the OPC UA tree; redeploy. Verified from the driver's
log line only, exactly as far as it can be verified.
- A metric name containing "/" cannot be BROWSE-COMMITTED: the derived raw tag
Name is a RawPath segment and may not contain "/", so the spec-mandatory
"Node Control/Rebirth" is refused ("Row 3: Name must not contain '/'"). The
refusal is loud and all-or-nothing, never a silently mis-bound tag, and
Manual entry is the working path. Fixing it needs a name-sanitisation policy
with a collision answer, so it was recorded rather than guessed at.
Also left open + documented: an empty browse tree cannot arm a rebirth (the
scope comes from a tree click, and the session side already accepts a bare
{group}/{edgeNode} — only a UI path is missing); _canRebirth is captured at
browse-open; the tag editor injects the Plain-only payloadFormat key into a
Sparkplug blob (cosmetic — the factory routes on the tuple).
Suites: offline 1528 passed / 0 failed (581 Driver.Mqtt + 809 AdminUI + 138
Core.Abstractions); live 15/15 against the broker + simulator.
Docs: docs/drivers/Mqtt.md brought fully up to date for P2 (Sparkplug config
sub-object, both tag shapes, the ingest state machine, rediscovery, browse +
rebirth + Refresh, a Known-gaps table); Mqtt-Test-Fixture.md gains the simulator
and drops its "Sparkplug has no fixture" claims; infra/README.md §3 gains the
simulator row; CLAUDE.md gains the simulator endpoint facts; the tracking doc
marks MQTT/Sparkplug COMPLETE. docker-dev/docker-compose.mqtt.yml is the
isolated-rig overlay the gate ran on.
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
|
||
|
|
07a4a5ff5e |
docs(mqtt): P1 plain-MQTT milestone live-verified; endpoint recorded
Task 14 — the P1 milestone gate. Ran the live /run verification on a docker-dev
rig against the real Mosquitto TLS+auth fixture, and recorded the result.
The gate did its job: it found MQTT was unauthorable in production.
RawDriverTypeDialog's driver-type list is a hand-maintained array that nobody
added MQTT to, so the /raw "New driver" picker never offered it — with every
other layer (contracts, driver, browser, factory, host registration, typed tag
editor) complete and 266 green unit tests. Nothing tied that array to
DriverTypeNames and AdminUI has no bUnit, so no offline test could see it.
Fixed, plus RawDriverTypeDialogParityTests: a reflection parity guard that
fails for ANY DriverTypeNames entry missing from the picker. Verified
falsifiable — RED with "…cannot be authored from the /raw New-driver picker,
so they are unreachable in production: Mqtt" before the one-line fix.
A second gap is left OPEN and documented, not fixed (no task ever covered it):
MqttDriverForm / MqttDeviceForm do not exist, and DriverConfigModal/DeviceModal
have no raw-JSON fallback — so an operator can create an MQTT driver but cannot
author its broker endpoint or credentials. P1 is not operator-complete until
those two razor forms land. The gate authored config via SQL to get past it.
Live gate result (isolated 2-node MAIN stack, image built from this branch,
fixture at 10.100.0.35:8883, AllowUntrustedServerCertificate rather than
pinning the CA into the rig):
- typed MQTT tag editor renders and round-trips; Json shows the JSON-path
field, Raw/Scalar hide it; wildcard topic a/+/c blocked at save; data-type
list offers Float64 and no Double; qos/retainSeed absent on "(driver
default)" and qos:2 written as a number; isHistorized/historianTagname
survive a topic-only edit; SparkplugB renders the P2 placeholder and
switching back keeps Plain values; jsonPath is guidance not a gate in all
three shapes ($ seeded only for a brand-new blank tag, blank stays absent,
clearing saves fine)
- deployed, and both editor-written blobs resolved and served changing live
values through OPC UA (22.8 / 1629, StatusCode Good) — no BadNodeIdUnknown
- the bespoke #-observation browser drove a real broker session and rendered
the fixture's actual topic tree (line1/{counter,state,temperature},
noise/chatter, retained/seed); a Modbus device's picker still correctly
reports "Browsing unavailable"
Also found live and documented (not a code change): both nodes of a redundant
pair run the driver, so a FIXED clientId makes them evict each other forever —
the broker logs "already connected, closing old connection" and both nodes
reconnect every ~2s while still reporting Healthy. Unset (the default) is
correct; confirmed 0 reconnects/60s on both nodes after removing it.
Suites: offline 1134 passed / 0 failed (266 Driver.Mqtt + 730 AdminUI incl. the
3 new guards + 138 Core.Abstractions); live 7/7 against the fixture.
Docs: new docs/drivers/Mqtt.md + Mqtt-Test-Fixture.md (the per-driver + fixture
convention every other driver follows), MQTT rows in docs/drivers/README.md,
TestConnectProbes.md, root README.md, and infra/README.md §3.
CLAUDE.md drift corrected while adding the MQTT endpoints:
- the "every fixture carries project: lmxopcua" claim was false — only the
MQTT fixture does; the filter returns one stack, not the fleet
- lmxopcua-fix.ps1 is Windows-VM-only; on macOS drive the host over ssh/rsync
(and the docker-dev rig itself runs locally under OrbStack)
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
|
||
|
|
e0ff908d26 |
docs(infra): fix memory pointers rendering as broken shortcut-links
The [reference_*] pointers target agent memory (not repo files) and rendered as undefined markdown shortcut-reference links; converted to plain code spans. All repo-relative links + paths in infra/README.md verified to resolve. |
||
|
|
1d3b6d1264 |
docs(infra): add infra/ folder — canonical testing + deployment infra index
Consolidates the scattered infra facts (docker host layout, driver fixtures, the three env-gated live-gate recipes, the Host.IntegrationTests harness, the HistGW local deploy, docker-dev rig, shared GLAuth, deploy) into infra/README.md as the single entry point, cross-linked to dev-environment.md + the deep docs. CLAUDE.md points at it from the Docker Workflow section. |