The build-platform note added alongside the proto wiring quoted docker-dev's
`FROM --platform=linux/amd64` verbatim inside an MSBuild comment. XML forbids
'--' in a comment, so MSBuild refused to load the project at all (MSB4025) --
a total build stop for every consumer of .Contracts, i.e. the whole MQTT
driver, the Host, and the test suite. Reworded to name the platform in prose.
Caught by rebuilding after the edit; the preceding commit was made from a
build that predated it.
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
Vendors the NORMATIVE (proto2) Eclipse Tahu sparkplug_b.proto and compiles it
in .Contracts with build-time Grpc.Tools, message-only (GrpcServices="None") --
Sparkplug rides MQTT, there is no gRPC service, so no Grpc.Core.Api is pulled in.
Provenance rides in the file header: repo, path, pinned commit
5736e404889d4b95910613040a99ba79589ffb13, permalink, git blob SHA-1
bf72ab5f..., content SHA-256 4432c5c4..., EPL-2.0, and a re-verify recipe. The
body below line 38 is byte-for-byte upstream; the blob SHA-1 matches the tree
entry at that commit, so the copy is provably genuine and not reconstructed.
Chose the proto2 file over upstream's sibling sparkplug_b_c_sharp.proto: the
sibling is a lossy proto3 restatement that drops explicit presence, and protoc
generates valid C# from proto2 into the identical namespace
(Org.Eclipse.Tahu.Protobuf, PascalCased from the package -- no
csharp_namespace option). Presence matters downstream: an NBIRTH legitimately
carries seq = 0 and a DATA metric legitimately omits `name`, so Has{Seq,Name,
Alias,IsNull,Datatype} is the difference between "absent" and "present, zero".
.Contracts stays transport-free: Google.Protobuf is a serialization dependency
with a framework-only graph, Grpc.Tools is PrivateAssets=all, and the resolved
graph is exactly {Google.Protobuf, Grpc.Tools, Core.Abstractions} -- no MQTTnet.
Codegen tests pin the round-trip, the namespace, the Sparkplug field numbers,
the DataType spec indices, and protoc's enum-name mangling (UInt64 -> Uint64,
UUID -> Uuid) that Task 17's datatype map has to spell correctly.
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
Task 9. Adds MqttDriverFactoryExtensions (DriverTypeName = DriverTypeNames.Mqtt,
direct deserialization of MqttDriverOptions — no intermediate DTO, mirroring
OpcUaClientDriverFactoryExtensions), the DriverTypeNames.Mqtt constant, and both
host wiring sites: the factory in DriverFactoryBootstrap.Register and the probe in
AddOtOpcUaDriverProbes (the admin-node path Program.cs calls in its hasAdmin
block — a probe wired only on driver nodes makes Test-connect silently dead).
Carried-forward items:
- Converges every MQTT config-parsing seam onto ONE JsonSerializerOptions —
MqttJson.Options, in .Contracts alongside MqttDriverOptions. It replaces the
probe's internal JsonOpts and the browser's separate private copy; the factory,
the probe, MqttDriver.ParseOptions and MqttDriverBrowser now all parse through
it. .Contracts is the only assembly all four consumers reference, and the
browser's reference to the runtime .Driver project is a documented layering
exception scheduled for removal — anchoring the options there would resurrect
the duplicate the day it goes away.
- Replaces the "Mqtt" literals in MqttDriverProbe, MqttDriverBrowser and
MqttDriver with the constant (string value unchanged).
- Tightens MqttDriverProbeTests.ProbeAsync_EnumAsName: it asserted only
Ok == false + non-empty message, which is also exactly what a JSON-parse
failure produces — so it stayed green under the very regression it names.
It now asserts the probe got past the parse and reached the network.
Falsifiability: deleting JsonStringEnumConverter from MqttJson.Options reddens 9
tests across 4 suites, including the tightened probe test (message becomes
"Config JSON is invalid: The JSON value could not be converted to
MqttProtocolVersion") — which the pre-fix assertions would have passed.
Also references the MQTT driver from Core.Abstractions.Tests so
DriverTypeNamesGuardTests' reflective bin scan discovers the new factory and the
constant/factory parity check stays honest.
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
Composes MqttConnection + MqttSubscriptionManager + LastValueCache into the
IDriver / ITagDiscovery / ISubscribable / IReadable / IHostConnectivityProbe /
IRediscoverable capability set.
- Discovery replays ONLY the authored raw tags (RediscoverPolicy = Once,
SupportsOnlineDiscovery = false) — a chatty broker can never auto-provision.
- Composition order is register -> AttachTo -> ConnectAsync; the manager's
Reconnected handler is passed through unwrapped so its throw-on-total-failure
still tears a deaf session down.
- ReinitializeAsync applies a tag-only delta in place and never faults on a bad
one; a session-changing delta rebuilds.
- ReadAsync serves the last-value cache and degrades per reference
(BadWaitingForInitialData), never throwing for the batch.
- FlushOptionalCachesAsync is a no-op: the last-value cache IS IReadable.
- Adds MqttDriverOptions.RawTags (the authored-tag delivery mechanism every
other driver's options DTO already has) and promotes MaxPayloadBytes from a
manager ctor knob to an operator-facing key.
- Converges on MqttDriverProbe.JsonOpts rather than a second, divergent
JsonSerializerOptions.
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
Task 2 review follow-up. The plan specified MqttEquipmentTagParser.TryParse(reference)
with def.Name = the TagConfig blob, and told us to mirror a type named
ModbusEquipmentTagParser. Both are plan defects:
- EquipmentTagRefResolver documents that a v3 driver reference "is now always a
RawPath" and that the blob-parse fallback is retired. Keying Name by the blob
would make OnDataChange publish under a reference that never matches the
RawPath-keyed fan-out in DriverHostActor - silently dead in production with
every unit test still green.
- ModbusEquipmentTagParser does not exist. The six sibling drivers all use
<Driver>TagDefinitionFactory.FromTagConfig(tagConfig, rawPath, out def).
Changes:
- Rename MqttEquipmentTagParser -> MqttTagDefinitionFactory; TryParse(reference,
out def) -> FromTagConfig(tagConfig, rawPath, out def) setting Name: rawPath,
matching ModbusTagDefinitionFactory's structure, param docs and guard order.
- Pin the identity contract with a dedicated test so a regression to blob-keying
goes red.
- Read qos with the same strictness as the enums: a present-but-invalid qos
("high" / 1.5 / 5 / null) now rejects the tag and is warned by Inspect,
instead of being silently absorbed into the driver-level default and handing
the operator a weaker delivery guarantee than the one they authored.
- No ToTagConfig inverse: the siblings carry one solely for their Driver.<X>.Cli
project, the MQTT plan defines none, and the AdminUI editor template
references no driver factory. Recorded as an explicit YAGNI call in the type
doc rather than added speculatively.
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
Code review of f22db5d8 (approved-with-findings): the existing round-trip
tests only exercised explicit JSON payloads, so nothing failed if UseTls /
AllowUntrustedServerCertificate or the §5.1 numeric defaults were flipped.
Adds a defaults-pinning test plus a partial-JSON test that omits the TLS
knobs entirely (the production case — an operator config that just doesn't
mention TLS must not silently land insecure).
Also overrides the record's PrintMembers so ToString() no longer prints
Password in plaintext (verified RED before the fix: the new test failed
with the raw password in the rendered string). OpcUaClientDriverOptions has
the same unredacted-ToString() shape but is out of scope for this task per
the coordinator's note; flagging as a possible follow-up.
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW