- ReplayAsync fails when its restarted pump's stream has already ended, so
the supervisor backs off and stays Degraded instead of going Healthy over
a dead stream (whose next advise re-report restarted at attempt 1 with no
backoff - a tight reconnect loop).
- ReconnectSupervisor.AttemptInProgress (reopen through replay); advises
wait for a stale pump's replacement only while an attempt is running, not
for a whole backoff (the state still reads Reopening/Replaying there).
- ReconnectSupervisor: _disposed is set under the state lock and re-checked
inside ReportTransportFailure, so a late report cannot start a recovery
loop that StopAsync already missed.
- EventPump.HasEnded is a flag set before StreamRequested is released, and
a stream that ends/faults on its first MoveNext is marked ended first.
- SubscriptionRegistry fast path: a miss now falls through to the locked
path (lookup + session + window check atomically) instead of a lock-free
re-lookup.
- Tests: replay over an immediately-ending stream fails; AttemptInProgress
across attempt/backoff; ReportTransportFailure after stop; the
reopen-window test uses a generous wait bound.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- StreamRequestWait 1 s (under Tier-A Read 2 s / Subscribe 5 s budgets) and
a stale pump is only waited on while the supervisor is reopening or
replaying (or a restart is underway); in a reconnect backoff the advise
proceeds at once. The no-stream log is a rate-limited Warning while
Healthy, Debug otherwise.
- A current-session pump whose loop has ended is not a stream: if the
supervisor already reports Healthy (its fault was swallowed while it was
recovering) the failure is re-reported to start a new cycle.
- Subscribe/Read no longer start the pump directly (only
AwaitCurrentEventStreamAsync does, honouring the replay restart flag);
the teardown refusal is an explicit ThrowIfRuntimeStopping.
- SubscriptionRegistry.ResolveOrPark fast path: the handle lookup and the
open-window check were not atomic, so a subscribe that registered the
handle and closed its window in between got its initial value dropped as
stale (found by a stress run: the first event of a bulk advise lost). It
re-looks-up before declaring stale. Deterministic test via a seam.
- Tests: first Read on a fresh driver, replay of a data subscription.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Round 1 replaced a stale-session pump from any advise path and disposed the
old one in the background; that could start a second stream while the old
one still held the gateway's single-subscriber slot, and a kept
current-session pump could be dead with no fault re-reported.
- EnsureEventPumpStarted reuses again; only ReplayAsync restarts the pump.
RestartEventPumpForReplay keeps a current-session pump only while its loop
is running (EventPump.HasEnded), and flags the restart so no advise path
starts a competing pump in the dispose gap.
- AwaitCurrentEventStreamAsync (bounded by StreamRequestWait) starts a pump
only when none exists, WAITS for the replay while the pump is stale or
restarting, waits for StreamRequested, and returns the session it verified.
SubscribeAsync (per #861 attempt), read-via-subscribe and the probe hook
issue and fence the advise under that session, so a reconnect after the
check is caught as a straddle and retried.
- Read: a deadline (not caller) cancel during the wait falls through to
per-ref results.
- Tests: reopen-window probe test now asserts the advise waits for the
replay's single new stream; first Subscribe/Read wait for the stream; the
fencing tests that advise in the window use a short wait bound; the
production-path seed test uses an empty galaxy (a real probe advise now
starts a stream against the fake endpoint).
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- EnsureEventPumpStarted replaces a pump created for an older registry
session (the reopen -> replay window still held the dead session's pump,
so an advise there lost its initial value and the replay skipped it);
RestartEventPumpForReplay keeps a pump already on the current session.
- SubscribeAsync, read-via-subscribe and ReplayAsync also await the
bounded StreamRequested wait before advising, not just the probes.
- TryEnsureEventPumpStarted tolerates a teardown flipping _runtimeStopping
mid-check; the probe hook honours an already-cancelled seed token.
- StreamRequested is documented as narrowing, not closing, the attach race.
- Tests: reopen-window probe test, EventPump.StreamRequested tests, and the
FixRound1 fresh-pump assertion now waits on a positive control.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
The gateway's StreamEvents with after_worker_sequence = 0 is a fresh stream
and never replays, and the event pump started only on the first
Read/Subscribe, so platform ScanState probes advised before then lost their
initial value (and a driver with no authored tags never got any host status).
PerPlatformProbeWatcher now awaits an ensure-event-stream hook before every
probe SubscribeBulk (seed, discover sync, reconnect ResubscribeStaleAsync).
The driver's hook starts the pump (refused while a teardown is in progress)
and waits, bounded, on the new EventPump.StreamRequested signal - completed
once the stream loop's first MoveNext has issued the StreamEvents RPC, or
when the loop ends - so the advise never precedes the stream request.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk