The HistorianGateway driver is now the sole historian read/write+alarm backend, so the
Wonderware sidecar projects are dead code. Removes the 5 Wonderware projects (driver,
.Client, .Client.Contracts, + their 2 test projects) from the solution and tree, and fully
retires the vestigial 'Historian.Wonderware' driver type (UI/probe-only; it had no driver
factory): the Host probe registration, the AdminUI driver-config surface (driver page,
tag-config editor/model/validator entry, address picker/builder, driver-type catalog +
dropdown + edit-router entries), and their tests. Prunes the now-unused Wonderware
connection fields (Host/Port/UseTls/ServerCertThumbprint/SharedSecret) from
AlarmHistorianOptions (keeping Enabled + the SQLite store-and-forward knobs) and refreshes
the stale XML docs that named Wonderware as the production backend.
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
AdminUI driver-instance pages serialized enum config fields (S7 CpuType,
Modbus DataType/Region, AbCip PlcFamily, ...) as JSON *numbers* because each
page's _jsonOpts lacked a JsonStringEnumConverter. The driver factories,
however, deserialize into string-typed DTOs (+ lenient ParseEnum) and throw
when binding a JSON number to a string? — so an AdminUI-authored config
containing any enum field produced a blob the driver could not parse,
faulting the driver on deploy. Proven end-to-end for S7 and Modbus; latent
for AbCip/AbLegacy/TwinCAT/FOCAS/Galaxy/Historian. Only OpcUaClient was safe
(its factory + probe already carried the converter).
Add JsonStringEnumConverter to all 9 driver-instance pages' _jsonOpts and the
8 missing driver probes' _opts (factories unchanged — already string-via-
ParseEnum; strictly more permissive, also lets pages load hand-seeded
string-enum configs back into the form).
Also fix DriverProbeHandshakeE2eTests.AbCip_Green_AgainstSim to probe a real
sim tag (TestDINT) — the no-tags @raw_cpu_type fallback is rejected by the
ab_server sim with ErrorBadParam (a real ControlLogix returns ErrorNotFound,
which the probe treats as reachable; hardware-gated follow-up).
Tests: reflection guard over all driver pages' _jsonOpts (AdminUI.Tests);
factory round-trip + numeric-form-throws guards for S7 and Modbus.
Found by running the never-before-run FB-9/FB-10 live verifies.
Audit (task #134) found the same Razor literal-binding bug class as the UNS
Filter fix (14b4692): a string-typed component parameter assigned without a
leading @ is a LITERAL, not an expression. Confirmed against the generated
.g.cs (literal "_error" vs TypeCheck<String>(_error)).
- DriverFormShell Error="_error" -> "@_error" on all 9 driver edit pages:
Error received the constant "_error", so the error banner rendered
permanently and the real failure message was never shown.
- DriverBrowseTree SelectedNodeId="_tagName"/"_nodeId" -> "@..." in the
Galaxy and OpcUaClient address pickers: the tree's selected-node highlight
compared against a literal that never matched a real node.
Build clean; generated code now binds all 11 as TypeCheck<String>(field);
AdminUI.Tests 216/216 green.
GalaxyDriverPage deserialized DriverConfig with case-sensitive camelCase opts, but the
persisted/seeded config is PascalCase (the runtime reads it case-insensitively). So all four
nested option records read as null -> FromRecord NRE (HTTP 500) on edit, and the form would
have shown defaults instead of the real config (risking a clobber on save). Fix: add
PropertyNameCaseInsensitive=true (matches the runtime) so real values load, plus null-coalesce
the nested records in FromRecord as defense-in-depth. Regression test asserts the seeded
PascalCase config loads its real values.
The driver/factory/seed use 'GalaxyMxGateway' (legacy 'Galaxy' was retired),
but the AdminUI editor router, GalaxyDriverPage, address picker, identity
dropdown, the Galaxy browser/probe, and DraftValidator still keyed on 'Galaxy'.
Result: the seeded GalaxyMxGateway driver couldn't be edited ('no editor
registered'), UI-created Galaxy drivers wrote a type with no factory, and a
SystemPlatform-bound GalaxyMxGateway driver failed publish validation.
Align all stragglers to GalaxyMxGateway (+ failing-test-first DraftValidator
coverage). ShouldStub's 'Galaxy' legacy safety-net left intact.
Capture the original ModbusTagDefinition as _source in ModbusTagRow and
rewrite ToDefinition() to use 'with {}', so StringByteOrder, ArrayCount,
Deadband, UnitId, and CoalesceProhibited survive a load→edit→save cycle.
- DriverTagPicker shell: modal chrome + per-driver picker body
rendered as ChildContent.
- 9 picker bodies (Modbus/AbCip/AbLegacy/S7/TwinCat/FOCAS/
OpcUaClient/Galaxy/Historian.Wonderware). 5 have computed
builder logic + unit tests; 4 are free-text passthroughs
(live browse for OPC UA + Galaxy is a documented follow-up).
- Each typed driver page gets a "Pick address" button that opens
the modal with the matching body. Picked address surfaces in
the modal footer for manual copy — no JS interop in v1.
- AdminProbeService routes TestDriverConnect through
IAdminOperationsClient with a 65s outer guard (actor side already
clamps to [1,60]).
- Added generic AskAsync<T> to IAdminOperationsClient interface and
AdminOperationsClient impl, delegating straight to the Akka proxy.
- DriverTestConnectButton renders the button + inline result chip,
auto-clears after 30s, disables during in-flight.
- Wired into all 9 typed driver pages directly under the
identity section. Sources timeout from the form's
ProbeTimeoutSeconds; sources config JSON from the form's
current Options (operator can test BEFORE saving).
Live panel subscribed to the /hubs/driverstatus SignalR feed —
renders state chip, last-success age, 5-min error count, last
error message. Auto-reconnect; dimmed when no push arrives for 30s.
Hidden for new instances (nothing deployed yet); shown read-only
on every edit-mode page. Reconnect/Restart buttons land in Phase 8.
- S7DriverPage.FormModel now preserves Tags through Form ↔ Options
translation (was hard-coding Tags = [] on every save, silently
destroying any tag list that operators had configured).
- Add FormModel_RoundTrip tests for OpcUaClient and Historian
mirror classes — both were translating Options ↔ form-model
entirely untested.
- Surface S7 Tags in the round-trip test so this regression
can't reach merge again.
All 9 driver types now have typed pages; DriverEditRouter dispatches
to them directly. Unknown DriverType strings (e.g. legacy rows) render
an explicit error notice instead of falling through to a generic
editor — the failure mode is now visible, not silent.
DriverEditRouter now dispatches every known DriverType to its typed
page. The legacy DriverEdit fallback remains in ResolveComponentType
for forward-compatibility with as-yet-unknown driver types but is no
longer reached for any current driver.
Adds /clusters/{ClusterId}/drivers/new picker page (Task 3.1). Renders
a 9-card Bootstrap grid — one card per driver type — each linking to
/clusters/{ClusterId}/drivers/new/{slug}. No data fetch; type list is
hardcoded. Route collides with DriverEdit.razor's same directive; Task
3.3 removes the duplicate to resolve the runtime ambiguity.