Commit Graph

10 Commits

Author SHA1 Message Date
Joseph Doherty 50b55ee4b9 fix(redundancy): elect the Primary by cluster age, not by address
RedundancyStateActor derived the driver Primary from ClusterState.RoleLeader("driver").
Akka offers two different notions of a "first" member and they are not the same
one: role leader is the lowest-ADDRESSED Up member (host, then port), while
ClusterSingletonManager places singletons on the OLDEST — lowest up-number.

They agree on a freshly-formed cluster, which is why every existing test passed.
They diverge after any restart: the restarted node re-joins as the youngest while
keeping its address, so if it holds the lower address it becomes role leader while
the singletons stay put. The snapshot would then name a Primary that is not
hosting the work, and every Primary-gated surface follows it — inbound device
writes, native-alarm acks, the fleet-wide alerts emit, and the alarm-history
drain would all enable on the wrong node while the node actually running the
singletons stayed gated off.

BuildSnapshot now selects the oldest Up member carrying the driver role, matching
singleton placement. Leaving members are excluded: a node handing its singletons
over must not be named Primary.

NodeRedundancyState.IsRoleLeaderForDriver is renamed IsDriverPrimary, and
NodeHealthInputs.IsDriverRoleLeader likewise. Keeping the old names would have
left the wire contract asserting a derivation the code no longer uses — the same
drift that made this defect invisible.

Proven by a real two-node cluster rather than a mock. RedundancyPrimaryElectionTests
binds the first-joining node to the HIGHER port, so oldest and lowest-address name
different nodes, and includes a fixture assertion that the divergence actually
occurred — without it the real assertion could pass for the wrong reason. Positive
control: restoring the RoleLeader derivation turns exactly the two election tests
red while the fixture check stays green.

Runtime.Tests 440 passed, ControlPlane.Tests 82, Cluster.Tests 36.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-21 18:39:07 -04:00
Joseph Doherty db751d12a5 feat(alarms): condition Quality tracks source connectivity (#477)
v2-ci / build (pull_request) Successful in 4m49s
v2-ci / unit-tests (pull_request) Failing after 3h11m25s
Part 9 ConditionType.Quality was never assigned; default(StatusCode)==Good
so every native + scripted condition reported Good unconditionally — a
comms-lost device still showed a healthy, inactive, Good condition (a
wrong-VALUE bug, distinct from the null-value #473/#475). Clients (and HMIs
bucketing on IsGood) could not tell "genuinely inactive" from "lost contact".

Layer 1 — make Quality a real, plumbed field:
- AlarmConditionSnapshot gains OpcUaQuality Quality (default Good).
- MaterialiseAlarmCondition sets it (native BadWaitingForInitialData, scripted Good).
- WriteAlarmCondition projects snapshot.Quality; the delta-gate gains a Quality
  member so a quality-bucket change fires a Part 9 event.

Layer 2 — drive native quality from driver connectivity (a comms-lost driver
emits no alarm transitions, and an alarm-bearing raw tag has no value variable,
so quality can't come from either existing channel):
- DriverInstanceActor Tells parent ConnectivityChanged on Connected/Reconnecting.
- DriverHostActor fans it to every native condition the driver owns as
  OpcUaPublishActor.AlarmQualityUpdate (Good on connect, Bad on disconnect).
- New dedicated IOpcUaAddressSpaceSink.WriteAlarmQuality sets ONLY Quality and
  fires only on a bucket change — never touches Active/Acked/Retain (an active
  alarm that loses comms stays active). Not a full-snapshot re-projection, so it
  can't clobber severity/message and works for a never-fired condition.
  Forwarded through DeferredAddressSpaceSink (F10b trap; auto-verified by the
  reflection forwarding guard). Ungated by redundancy role; no /alerts row.

Scripted conditions stay Good; worst-of-input quality deferred to #478 (Layer 3).

Tests: node-level (materialise/project/no-clobber/unknown-node no-op),
NativeAlarmProjector, DriverInstanceActor connectivity emission, DriverHostActor
fan-out, OpcUaPublishActor routing, and the wire-level guard
(Condition_event_Quality_tracks_source_connectivity_on_the_wire) — RED-verified
against a simulated pre-fix always-Good server. Existing DriverInstanceActor
parent probes ignore the new ConnectivityChanged.

Docs: docs/AlarmTracking.md §"Condition source-data Quality (#477)";
design doc docs/plans/2026-07-17-alarm-condition-quality-477-design.md.
2026-07-17 15:10:04 -04:00
Joseph Doherty 8ebc712eff feat(v3-batch4-wp4): multi-notifier native alarms (single ReportEvent → raw + equipment notifiers) + teardown symmetry
Materialize each native alarm ONCE at the raw tag (ConditionId = RawPath, Raw
realm); wire the single condition as an SDK event notifier of each referencing
equipment's UNS folder so one ReportEvent fans to every root without
re-reporting per root (which would break Server-object dedup + Part 9 ack
correlation).

- New sink method WireAlarmNotifiers(alarmNodeId, alarmRealm,
  notifierFolderNodeIds, notifierFolderRealm) on IOpcUaAddressSpaceSink,
  forwarded through DeferredAddressSpaceSink + SdkAddressSpaceSink +
  NullOpcUaAddressSpaceSink (the forwarding-trap guard); auto-covered by the
  DeferredSinkForwardingReflectionTests realm + forwarding guards + a
  hand-written forward test.
- OtOpcUaNodeManager: the normative AddNotifier(isInverse) pair + idempotent
  EnsureFolderIsEventNotifier per equipment folder; tracked per condition in
  _alarmNotifierWiring. Teardown symmetry: RemoveNotifier(bidirectional:true) on
  RebuildAddressSpace, RemoveAlarmConditionNode, and RemoveEquipmentSubtree so no
  inverse-notifier entry leaks across redeploys.
- AddressSpaceApplier.MaterialiseRawSubtree wires notifiers for each native alarm
  tag, resolving its ReferencingEquipmentPaths (Area/Line/Equipment) to the
  EquipmentId folder NodeIds via BuildEquipmentIdByFolderPath.
- AlarmTransitionEvent gains ReferencingEquipmentPaths (empty default); /alerts
  renders the referencing-equipment list as display metadata.
- Un-skipped + rewrote the native-alarm dark tests
  (DriverHostActorNativeAlarmTests x6, DriverHostActorNativeAlarmAckRoutingTests
  x1) for the v3 raw-condition model; new NodeManagerMultiNotifierAlarmTests
  proves multi-notifier wiring + teardown symmetry (no leaked duplicates after a
  re-trip) + applier wiring test.

Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
2026-07-16 12:07:11 -04:00
Joseph Doherty 329144b1aa v3 B1-WP6: migrate Core + Server test projects to greenfield schema
Fix TESTS only (production already green) so the four in-scope test projects
compile + pass under the v3 dark address space:

- Core.Abstractions.Tests: drop AllowedNamespaceKinds/NamespaceKindCompatibility
  from DriverTypeMetadata; rewrite EquipmentTagRefResolver tests to the single-func
  RawPath-lookup contract (no parseRef/transient cache).
- Core.Tests: rewrite EquipmentNodeWalkerTests to EquipmentNamespaceContent(Areas,
  Lines,Equipment,VirtualTags?,ScriptedAlarms?) — folders + VirtualTags +
  ScriptedAlarms only; raw-tag variables dark (skipped Batch-4 placeholder). Drop
  retired Equipment.DriverInstanceId.
- Runtime.Tests: rewrite golden corpus + TagConfigCorpusParityTests to the v3
  RawPath/RawTagEntry round-trip (byte + TagConfigIntent parity; EquipmentTags dark).
  Salvage VirtualTag + ScriptedAlarm artifact parity to the new Compose signature.
  Retire the equipment-tag-materialization parity files (Array/Historize/Alias) and
  the equipment-device-binding DeviceHost parity to documented skipped placeholders.
  Skip 34 dark equipment-tag routing/value/alarm/write/discovery actor tests with a
  shared DarkAddressSpaceReasons constant. Re-key cluster-scoped tests to v3 UNS
  line->area attribution.
- ControlPlane.Tests: ConfigComposer round-trips re-keyed to RawFolder/Device (no
  Namespaces); tag-config gate resolves driver via Device; deploy-gate collision test
  re-keyed to UnsEffectiveNameCollision; drop retired BadCrossClusterNamespaceBinding
  case.
2026-07-15 21:26:00 -04:00
Joseph Doherty 6a8020e7e7 feat(adminui): native-alarm HistorizeToAveva opt-out 2026-06-16 16:27:31 -04:00
Joseph Doherty 51cda2c744 test(alarms): assert OperatorComment flows through ForwardNativeAlarm 2026-06-14 22:41:43 -04:00
Joseph Doherty f9be38430c fix(alarms): route native alarms by ConditionId (dotted FullName), not bare SourceNodeId (integration review)
v2-ci / build (push) Failing after 46s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
2026-06-14 04:09:01 -04:00
Joseph Doherty 7e86fa7099 fix(alarms): normalise native TransitionKind to canonical EmissionKind vocabulary (review) 2026-06-14 03:58:46 -04:00
Joseph Doherty 8736fcc37c feat(alarms): Primary-gated AlarmTransitionEvent fan-out for native alarms (Phase B WS-5) 2026-06-14 03:48:41 -04:00
Joseph Doherty 4c56a1719b feat(alarms): DriverHostActor routes native alarm transitions to Part 9 conditions (Phase B WS-4c) 2026-06-14 03:34:25 -04:00