The HistorianGateway driver is now the sole historian read/write+alarm backend, so the
Wonderware sidecar projects are dead code. Removes the 5 Wonderware projects (driver,
.Client, .Client.Contracts, + their 2 test projects) from the solution and tree, and fully
retires the vestigial 'Historian.Wonderware' driver type (UI/probe-only; it had no driver
factory): the Host probe registration, the AdminUI driver-config surface (driver page,
tag-config editor/model/validator entry, address picker/builder, driver-type catalog +
dropdown + edit-router entries), and their tests. Prunes the now-unused Wonderware
connection fields (Host/Port/UseTls/ServerCertThumbprint/SharedSecret) from
AlarmHistorianOptions (keeping Enabled + the SQLite store-and-forward knobs) and refreshes
the stale XML docs that named Wonderware as the production backend.
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
Both bugs surfaced only on split-role deployments (the MAIN cluster's
admin-only nodes), where the AdminUI runs without the driver role.
- Test Connect returned "No probe registered" for every driver: the
IDriverProbe set was registered only under the driver role, but the
admin-operations singleton that consumes it is pinned to admin. Extract
AddOtOpcUaDriverProbes() (idempotent via TryAddEnumerable) and call it
in the hasAdmin path too.
- Live driver-status/alerts/script-log panels showed "SignalR error:
Connection refused": these Blazor Server components opened a HubConnection
to their own hub via the browser's public URL, which server-side code
can't reach behind Traefik (host :9200 -> container :9000). Read the
in-process source directly instead -- DriverStatus via
IDriverStatusSnapshotStore.SnapshotChanged, Alerts/ScriptLog via a new
IInProcessBroadcaster<T>. Fleet status was unaffected (reads DB/ActorSystem).
Adds unit tests for probe registration, the snapshot-store event, and the
broadcaster.