Joseph Doherty e39a125069 fix(acl): close the #808 review findings — reference variables, owner folder chain, NUL keys, unknown ids (#808)
Review of af5c9744:
1. UNS reference variables (s=Area/Line/Equip/Eff) of a moved or renamed
   equipment stayed readable/writable under the OLD names' grants: they now
   resolve as ReferenceVariable and are authorized at their split path only
   while it equals their live equipment folder's placement (live chain ==
   generation chain) + one name; otherwise denied (Read and Write).
2. TryPlaceScriptedCondition now also requires the owner folder's live chain
   to match the generation (AuthorizeScriptedCondition gains ownerFolderChain),
   so a moved equipment's alarm/children/commands follow its folder.
3. Identifiers containing NUL are denied before the decision cache, keeping
   client ids disjoint from the NUL-prefixed resolved-scope keys (a client
   could otherwise poison a real folder's cached verdict for its key shard).
4. An id no live node holds is Unknown: placed at [\0unknown] so only
   Cluster / Namespace-uns grants decide it (a removed opaque id can no longer
   split onto a same-named narrow grant; narrow grantees get no NodeDeleted for
   removed UNS folders/vtags/conditions — documented); 4-segment
   reference-shaped ids keep their split.
5. A wire test drives placements from DeploymentArtifact.ParseDataPlaneAuthority.

Baseline updates: #797 owner tests (unit + wire) and Sdk2RepeatedAlarmAuthority
now install folder scopes; Sdk2HistoryAuthority's UNS alias used the RAW path
as its UNS id (never minted in production) and now carries EqA/HistoryAlias.
Each new guard was falsified (reverting it fails its test).
2026-11-10 23:44:11 -05:00
Joseph Doherty af5c9744b7 fix(acl): place opaque-id UNS folders, virtual tags and scripted conditions for every operation (#808)
UNS Area/Line/Equipment folders are minted under their opaque entity ids
(s=UA-/UL-/EQ-...), virtual tags under s=EQ-.../Name and scripted conditions
(+ #629 children) under s=<ScriptedAlarmId>[/...], while every UNS grant is
planted at a NAME path. DataPlaneAuthorizer split those ids, so with
Security:Acl:Enabled a narrow (Area/Line/Equipment) grant could not Browse,
Read, subscribe or HistoryRead them, and Server-object delivery never reached
it — so a narrow key never held the EventId Ack/Confirm/AddComment need.

- The generation carries UnsFolderScopes (folderId -> path + id chain), built
  by DeploymentArtifact from the same AclScopePathResolver as the grants; ids
  two entity kinds share are dropped; plumbed through IDataPlaneAuthoritySink.
- OtOpcUaNodeManager.ResolveUnsAclSubject reports live facts (folder id
  ancestry / scripted owner binding); attached by the Authorizer setter.
- Evaluate places the subject against the CURRENT generation before the
  decision cache, which now caches the walk keyed on the resolved scope.
  Folders require live chain == generation chain (a moved equipment is denied
  under old and new line until the rebuild). Owned nodes (vtags, conditions,
  children) get owner path + a reserved segment, so Tag grants and their
  Browse transit never expose them. Conditions share TryPlaceScriptedCondition
  with the #797 command gate.
- Server-object visibility of a scripted condition is decided on the
  condition alone, so a moved alarm cannot reach its old owner there.

Tests: UnsFolderScopeWireTests (opaque ids, end-to-end browse -> EventId ->
Acknowledge on an Equipment grant; sibling denied; Tag-only grant; moved alarm
and moved equipment stale windows). Rig tests now install folder scopes
explicitly (ServerEventRig.FolderScopes); the #797 recreate test deliberately
asserts the moved alarm is invisible to the Cluster observer in the window.
2026-11-10 23:12:46 -05:00