- DecodeRegisterArray: add String and BitInRegister cases replacing the
default:throw; each element decoded by reusing DecodeRegister on its
contiguous register slice → string[] / bool[]
- ModbusEquipmentTagParser.TryParse: read optional arrayLength key from
TagConfig JSON and thread it into ModbusTagDefinition.ArrayCount
(null when absent or zero, preserving scalar behaviour)
- ModbusArrayTests: 8 new tests covering the two decode cases and the
equipment-tag parser/resolver path; 285/285 green
Extends RecordingSink to capture isArray/arrayLength per EnsureVariable call,
adds two applier-level tests asserting the wire-through for array and scalar
plans, adds float/overflow InlineData rows to ExtractTagArray theory, and
corrects the ExtractTagArray XML-doc wording (null => unbounded ArrayDimensions=[0]).
Two bugs caught by live verification against the mxaccessgw at 10.100.0.48:5120:
- MaxAttempts=1 produced an invalid Polly RetryStrategyOptions -> the probe failed
on every real gateway. Removed the Retry override (matches GalaxyDriver); fail-fast
is already guaranteed by the TCP preflight + the per-call deadline.
- A rejected key surfaces as a typed MxGatewayAuthenticationException, not a raw
RpcException, so 'auth-rejection = reachable' was bypassed. Catch the typed auth/
authorization exceptions -> Ok=true.
Adds DriverProbeHandshakeE2eTests: direct-probe, skip-gated cross-protocol green/red
discrimination (Modbus, OpcUaClient, Galaxy + a local real OPC UA server).
Replaces the bare-TCP AbLegacyDriverProbe with a two-phase probe:
Phase 1 is the existing TCP preflight; Phase 2 initialises a
LibplctagLegacyTagRuntime (Protocol.ab_eip + per-family PlcType) to
open a real PCCC-over-EIP session, using AbLegacyProbeOptions.ProbeAddress
("S:0") as the probe tag. Status-code discrimination mirrors the AbCip
probe: ErrorNotFound/ErrorNoMatch/ErrorBadDevice → Ok=true "controller
reachable"; transport errors → Ok=false "handshake failed".
Adds AbLegacyDriverProbeTests (5 unit tests, all green, 168 total).
Replace the bare-TCP-only AbCipDriverProbe with a two-phase check:
Phase 1 keeps the existing TCP preflight; Phase 2 initialises a
LibplctagTagRuntime against the first device to open a real EIP session
and CIP Forward Open, so a live-but-rejecting CIP endpoint reads red
instead of a false-positive green.
Status mapping: ErrorNotFound / ErrorNoMatch / ErrorBadDevice → reachable
(controller answered CIP, probe tag absent); ErrorTimeout / ErrorBadConnection
/ ErrorBadGateway / ErrorWinsock / ErrorOpen / ErrorClose / ErrorRead /
ErrorWrite / ErrorBadReply / ErrorRemoteErr / ErrorPartial / ErrorAbort →
handshake failed. LibPlcTagException message text is used as a secondary
signal for the reachable-exception path. All other statuses default to
handshake-failed (conservative).
Add AbCipDriverProbeTests: invalid JSON, no devices, malformed host address,
closed-port TCP rejection, and black-hole timeout — all offline-determinable.
Happy path + CIP-error path covered live against the CIP sim.
Replace the bare TCP-connect return in OpcUaClientDriverProbe with a real
OPC UA GetEndpoints discovery handshake (mirroring SelectMatchingEndpointAsync
in the driver). TCP preflight still fast-fails closed ports; the handshake
confirms the remote is actually an OPC UA server, so a live-but-rejecting
non-OPC-UA process now reads RED instead of a false-healthy green.
Replace bare TCP-connect with a two-phase probe: Phase 1 keeps the
existing SocketException / timeout / generic preflight paths unchanged;
Phase 2 runs Plc.OpenAsync (COTP CR/CC + S7 setup-communication) so a
device that accepts TCP but is not an S7 PLC reads red instead of green.
A linked CTS distinguishes caller cancellation ("timed out") from the
S7netplus internal read-timeout OCE ("handshake failed: timed out").
Replace the bare TCP-connect probe in ModbusDriverProbe with a two-phase
check: TCP connect via ModbusTcpTransport (keeps the same SocketException /
timeout / generic error paths and messages), then a one-shot FC03 Read
Holding Registers (qty 1 @ addr 0). A normal response → Ok=true "Modbus
FC03 OK"; a Modbus exception PDU → Ok=true "Modbus FC03 OK (device
returned exception PDU)"; any other failure after TCP succeeds → Ok=false
"Reachable at host:port but Modbus FC03 handshake failed: …".
Add ModbusDriverProbeTests (6 tests) covering invalid JSON, missing
host/port, closed port, TCP-accept-then-close, canned MBAP happy path,
and Modbus exception PDU path. All 277 Modbus tests green.