607dc51dec feat(opcua): #85 UNS Area/Line/Equipment folder hierarchy in SDK
Some checks failed
v2-ci / build (push) Failing after 42s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (push) Has been skipped
Phase7Composer now carries UnsAreaProjection + UnsLineProjection lists so
the applier can materialise the full UNS topology in the OPC UA address
space. New IOpcUaAddressSpaceSink.EnsureFolder(folderNodeId, parentNodeId,
displayName) seam (no-op default, recorded in tests, forwarded by
DeferredAddressSpaceSink, implemented by SdkAddressSpaceSink). The SDK-
side OtOpcUaNodeManager gains an EnsureFolder API that creates
FolderState nodes with proper parent linkage; RebuildAddressSpace now
clears folders too so re-applies don't accumulate stale topology.

Phase7Applier.MaterialiseHierarchy walks composition.UnsAreas →
composition.UnsLines → composition.EquipmentNodes, calling EnsureFolder
with the correct parent at each level. Idempotent — calling twice with
the same composition is a no-op. OpcUaPublishActor.HandleRebuild invokes
it after Phase7Applier.Apply so OPC UA clients browsing the server now
see Area/Line/Equipment as proper folders rather than flat tag ids.

DeploymentArtifact.ParseComposition reads UnsAreas + UnsLines from the
JSON snapshot the ControlPlane emits, populating the new fields when
present.

Phase7Composer.Compose now accepts UnsAreas + UnsLines; a 3-arg overload
preserves the old signature for legacy callers + existing tests. The
Phase7CompositionResult convenience ctor likewise keeps the planner
tests working without UNS data.

3 new hierarchy tests (pure unit + boot-verify against a real
OtOpcUaSdkServer); OpcUaServer suite is 48/48 green (was 45, +3),
Runtime 74/74 unchanged.

Closes #85.
2026-05-26 10:48:56 -04:00
Joseph Doherty
c02f016f1d feat(opcua): F14 Phase7Plan + Phase7Applier
Some checks failed
v2-ci / build (push) Failing after 34s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (push) Has been skipped
Splits the side-effecting half of Phase7Composer (deferred at Task 47)
into two pieces that mirror DriverHostActor's spawn-plan pattern:

Phase7Plan + Phase7Planner.Compute (pure):
  Diff two Phase7CompositionResult snapshots by stable id (EquipmentId,
  DriverInstanceId, ScriptedAlarmId). Emits Added/Removed/Changed lists
  per entity class. Added/Removed are sorted by id for deterministic
  apply order. Changed wraps both Previous and Current projections so
  consumers can decide between in-place mutation and tear-down +
  rebuild.

Phase7Applier (side-effecting):
  Drives an IOpcUaAddressSpaceSink against a plan. Removed equipment/
  alarms get an inactive AlarmState write per id; Added/Removed of
  Equipment or ScriptedAlarm triggers RebuildAddressSpace. Driver-only
  changes correctly skip the rebuild — those flow through DriverHost-
  Actor's spawn-plan in Runtime. Sink exceptions are caught + logged so
  one bad node doesn't abort the apply.

Tests: OpcUaServer 6 -> 20 (+14):
- Phase7PlannerTests x9 (empty-in/empty-out, add/remove/change per
  entity class, mixed changes, deterministic ordering)
- Phase7ApplierTests x5 (empty plan no-op, removal writes inactive
  states + rebuild, added equipment triggers rebuild, driver-only
  skips rebuild, sink fault is non-fatal)

The remaining piece is the EquipmentNodeWalker integration against a
real SDK NodeManager — split as F14b, gated on F10b's SDK builder.

All 6 v2 test suites green: 146 tests passing.
2026-05-26 09:16:08 -04:00