Event items on an equipment / raw device folder were fed by the SDK's MonitoredNode2 fan-out with no ACL
decision, so after a deploy moved a scripted alarm (or dropped the reference projecting a native alarm into
an equipment) the OLD folder's subscribers kept receiving it - EventId included - until the rebuild landed,
indefinitely after a failed apply.
- OtOpcUaNodeManager re-implements INodeManager3 so ValidateEventRolePermissions (the SDK's per-event,
per-item hook; base not virtual) adds IsNotifierEventVisibleTo: live condition instance, notifier still a
legitimate notifier of it, and the #586/#808 Server-object rule (IsConditionVisibleTo over
ConditionVisibilityScopes).
- The SDK memoizes that verdict per (item, event type, SourceNode): InvalidateFolderEventVerdicts runs on the
authority/authorizer setters, RevalidateMonitoredItems (deploy + timer) and CompleteAddressSpaceApply.
- ConditionRefresh on direct items goes through RefreshDirectItems (base loop + the same decision).
- New generation field TagReferencingEquipment (RawPath -> EquipmentIds, from the artifact's
UnsTagReferences via AclScopePathResolver.ResolveTagRawPath): a native alarm's wired equipment folder only
counts (folder delivery AND Server-object scopes) while the current generation still references it.
- Secondary #808 edge: UNS variables wired UNS->Raw Organizes by AddReference are tracked and always placed
as reference variables (an Area named like its equipment's id no longer narrows them).
Tests: UnsFolderScopeWireTests (moved alarm on a folder item + ConditionRefresh + rebuild; area named like
equipment id), NativeAlarmFolderEventAclWireTests (dropped reference: folder + Server object + refresh +
restore), DeploymentArtifactScopePathTests (projection). Rig/event tests now supply tag references.
Review of af5c9744:
1. UNS reference variables (s=Area/Line/Equip/Eff) of a moved or renamed
equipment stayed readable/writable under the OLD names' grants: they now
resolve as ReferenceVariable and are authorized at their split path only
while it equals their live equipment folder's placement (live chain ==
generation chain) + one name; otherwise denied (Read and Write).
2. TryPlaceScriptedCondition now also requires the owner folder's live chain
to match the generation (AuthorizeScriptedCondition gains ownerFolderChain),
so a moved equipment's alarm/children/commands follow its folder.
3. Identifiers containing NUL are denied before the decision cache, keeping
client ids disjoint from the NUL-prefixed resolved-scope keys (a client
could otherwise poison a real folder's cached verdict for its key shard).
4. An id no live node holds is Unknown: placed at [\0unknown] so only
Cluster / Namespace-uns grants decide it (a removed opaque id can no longer
split onto a same-named narrow grant; narrow grantees get no NodeDeleted for
removed UNS folders/vtags/conditions — documented); 4-segment
reference-shaped ids keep their split.
5. A wire test drives placements from DeploymentArtifact.ParseDataPlaneAuthority.
Baseline updates: #797 owner tests (unit + wire) and Sdk2RepeatedAlarmAuthority
now install folder scopes; Sdk2HistoryAuthority's UNS alias used the RAW path
as its UNS id (never minted in production) and now carries EqA/HistoryAlias.
Each new guard was falsified (reverting it fails its test).
UNS Area/Line/Equipment folders are minted under their opaque entity ids
(s=UA-/UL-/EQ-...), virtual tags under s=EQ-.../Name and scripted conditions
(+ #629 children) under s=<ScriptedAlarmId>[/...], while every UNS grant is
planted at a NAME path. DataPlaneAuthorizer split those ids, so with
Security:Acl:Enabled a narrow (Area/Line/Equipment) grant could not Browse,
Read, subscribe or HistoryRead them, and Server-object delivery never reached
it — so a narrow key never held the EventId Ack/Confirm/AddComment need.
- The generation carries UnsFolderScopes (folderId -> path + id chain), built
by DeploymentArtifact from the same AclScopePathResolver as the grants; ids
two entity kinds share are dropped; plumbed through IDataPlaneAuthoritySink.
- OtOpcUaNodeManager.ResolveUnsAclSubject reports live facts (folder id
ancestry / scripted owner binding); attached by the Authorizer setter.
- Evaluate places the subject against the CURRENT generation before the
decision cache, which now caches the walk keyed on the resolved scope.
Folders require live chain == generation chain (a moved equipment is denied
under old and new line until the rebuild). Owned nodes (vtags, conditions,
children) get owner path + a reserved segment, so Tag grants and their
Browse transit never expose them. Conditions share TryPlaceScriptedCondition
with the #797 command gate.
- Server-object visibility of a scripted condition is decided on the
condition alone, so a moved alarm cannot reach its old owner there.
Tests: UnsFolderScopeWireTests (opaque ids, end-to-end browse -> EventId ->
Acknowledge on an Equipment grant; sibling denied; Tag-only grant; moved alarm
and moved equipment stale windows). Rig tests now install folder scopes
explicitly (ServerEventRig.FolderScopes); the #797 recreate test deliberately
asserts the moved alarm is invisible to the Cluster observer in the window.