Since #855 condition events are queued to folder event items under the node
manager Lock. At a full DiscardOldest queue the SDK's EventQueueHandler
dequeues the head of EventMonitoredItemQueue, a List.RemoveAt(0) shift of the
whole queue (~1 us/item at QueueSize 1000, ~10 us at 10000).
OtOpcUaSdkServer.CreateMonitoredItemQueueFactory now wraps the SDK factory in
RingEventQueueFactory: event queues are RingEventMonitoredItemQueue (O(1)
discard), data-change queues, durable requests and disposal go to the SDK
factory unchanged. A factory set through StandardServer.MonitoredItemQueueFactory
is used as-is.
The SDK queue is storage only (decompiled 2.0.1): DiscardOldest, overflow-event
positions and discarded/overflow counters live in EventQueueHandler, which is
unchanged. The ring reproduces QueueSize 0 initial + BadInternalError enqueue,
drop-oldest at Count == QueueSize, FIFO dequeue, SetQueueSize keep-newest /
keep-oldest, the newest-1000 duplicate window via IsEventRaisedFor, no-op
Dispose. RingEventMonitoredItemQueueParityTests drive both queues, and the SDK
EventQueueHandler over both factories, with the same random sequences.
FolderEventDeliveryPerfTests gains Ring_vs_sdk_event_queue (A/B in one process
via the internal OtOpcUaSdkServer.RingEventQueues switch).
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
FolderEventDeliveryPerfTests (Category=Perf, skipped unless OTOPCUA_EVENT_PERF=1)
reports per-alarm-report node-manager Lock hold and end-to-end delivery latency
for one equipment folder with N = 1/10/50/200 event items, ACL on/off, folder
subscribers publishing or stalled at a full queue; the latency of an i=2253
subscriber while folder subscribers stall; and a QueueSize sensitivity sweep.
Compiles against the pre-#855 tree for a before/after comparison.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk