Widen the F10b surgical address-space path so a changed equipment tag whose
only differences are DataType / IsArray / ArrayLength (on top of the existing
Writable / Historizing) is applied IN PLACE on the live node instead of forcing
a full RebuildAddressSpace that drops every client's subscriptions server-wide.
ISurgicalAddressSpaceSink.UpdateTagAttributes gains (dataType, isArray,
arrayLength); the DeferredAddressSpaceSink wrapper forwards all six args (the
prod-inertness seam). OtOpcUaNodeManager swaps DataType + ValueRank +
ArrayDimensions in place, and on a real shape change (a) resets the node to
BadWaitingForInitialData so no stale wrong-typed value is exposed (closes the
prior brief-value-type-mismatch objection) and (b) raises a Part 3
GeneralModelChangeEvent (verb=DataTypeChanged) so model-aware clients re-read
the definition. A Writable/Historizing-only change leaves the shape untouched
(no reset, no model event) — original behaviour preserved byte-for-byte.
AddressSpaceApplier.TagDeltaIsSurgicalEligible adds the three shape fields to
its whitelist; FullName/Name/DriverInstanceId/alarm differences still rebuild.
Tests: new NodeManagerSurgicalShapeUpdateTests boots a real server to prove the
in-place swap + value reset + the no-reset backward-compat path + the model-event
builder; AddressSpaceApplierTests invert the two former DataType/IsArray-rebuild
cases to surgical and assert the shape args land; DeferredAddressSpaceSinkTests
assert the shape args forward. 273/273 OpcUaServer.Tests green; full solution builds.
The OPC UA address-space build pipeline was named after a v2-roadmap
milestone number rather than its domain. Rename the family to describe
what it does (build/diff/apply the OPC UA address space):
Phase7Composer -> AddressSpaceComposer
Phase7CompositionResult -> AddressSpaceComposition
Phase7Planner -> AddressSpacePlanner
Phase7Plan -> AddressSpacePlan
Phase7Applier -> AddressSpaceApplier
Phase7ApplyOutcome -> AddressSpaceApplyOutcome
The 9 Phase7*Tests suites follow suit; Phase7ScriptingEntitiesTests ->
ScriptingEntitiesTests (it tests the scripting migration, not the
pipeline). Log-message prefixes move to the new class names.
Pure mechanical rename, no behavioral change. EF migration classes/IDs
(AddPhase7ScriptingTables, ExtendComputeGenerationDiffWithPhase7) are
immutable and left untouched, as are historical design docs.
Build clean; OpcUaServer 261/261, Runtime 272/272, ScriptingEntities
12/12 green.
I1: DeferredAddressSpaceSinkTests.RecordingSink now captures HistorianTagname
per EnsureVariable call (HistorianQueue/HistorianCalls, matching the
Phase7ApplierTests pattern); new test EnsureVariable_forwards_historianTagname_to_inner_sink
asserts the arg is forwarded unchanged through DeferredAddressSpaceSink.
M1: OtOpcUaNodeManager.EnsureVariable doc-comment notes that a changed
historize intent on an already-registered node is silently ignored until
a RebuildAddressSpace (rebuild precondition for Task 3 implementers).
N2: DeploymentArtifact.ExtractTagHistorize doc wording: "The live-edit
side" → "The live-edit composer side".
Resolves the 12 reported build errors (7 CS0535 sink fakes + 5 CLI CS1587).
Runtime.Tests green (74). NOTE: OpcUaServer.Tests still has pre-existing CS7036
errors from the in-progress Galaxy-tag workstream (Phase7Plan/Phase7CompositionResult
new required params) — separate, test-only, not addressed here.
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
Phase7Composer now carries UnsAreaProjection + UnsLineProjection lists so
the applier can materialise the full UNS topology in the OPC UA address
space. New IOpcUaAddressSpaceSink.EnsureFolder(folderNodeId, parentNodeId,
displayName) seam (no-op default, recorded in tests, forwarded by
DeferredAddressSpaceSink, implemented by SdkAddressSpaceSink). The SDK-
side OtOpcUaNodeManager gains an EnsureFolder API that creates
FolderState nodes with proper parent linkage; RebuildAddressSpace now
clears folders too so re-applies don't accumulate stale topology.
Phase7Applier.MaterialiseHierarchy walks composition.UnsAreas →
composition.UnsLines → composition.EquipmentNodes, calling EnsureFolder
with the correct parent at each level. Idempotent — calling twice with
the same composition is a no-op. OpcUaPublishActor.HandleRebuild invokes
it after Phase7Applier.Apply so OPC UA clients browsing the server now
see Area/Line/Equipment as proper folders rather than flat tag ids.
DeploymentArtifact.ParseComposition reads UnsAreas + UnsLines from the
JSON snapshot the ControlPlane emits, populating the new fields when
present.
Phase7Composer.Compose now accepts UnsAreas + UnsLines; a 3-arg overload
preserves the old signature for legacy callers + existing tests. The
Phase7CompositionResult convenience ctor likewise keeps the planner
tests working without UNS data.
3 new hierarchy tests (pure unit + boot-verify against a real
OtOpcUaSdkServer); OpcUaServer suite is 48/48 green (was 45, +3),
Runtime 74/74 unchanged.
Closes#85.
Wires the OPC UA SDK into the fused Host's lifecycle on driver-role
nodes + spawns OpcUaPublishActor with the proper sink/publisher/dbFactory/
applier resolution. The full read+write data path is now live in
production: Deploy → DriverHost → OpcUaPublish → SDK NodeManager →
subscribed OPC UA clients.
DeferredAddressSpaceSink (Commons.OpcUa):
- Thread-safe wrapper IOpcUaAddressSpaceSink that delegates to an
inner sink swapped in at runtime. Needed because Akka actors
resolve the sink at construction time, but the production sink
(SdkAddressSpaceSink wrapping OtOpcUaNodeManager) only exists
after the SDK StandardServer has started.
- Defaults to NullOpcUaAddressSpaceSink so calls before swap are
safe; SetSink(null) reverts (for graceful shutdown).
OtOpcUaServerHostedService (Host.OpcUa):
- IHostedService that owns the OPC UA SDK lifecycle. Reads
OpcUaApplicationHostOptions from the 'OpcUa' config section,
creates an OtOpcUaSdkServer, boots it through OpcUaApplicationHost,
then swaps a real SdkAddressSpaceSink into the DeferredAddressSpaceSink
singleton.
- SDK boot failure is logged + non-fatal — the rest of the host
(admin UI, driver actors) keeps running. Stop reverts to null sink.
WithOtOpcUaRuntimeActors (Runtime):
- Now spawns OpcUaPublishActor (new actor) + threads its ActorRef
into DriverHostActor's Props so successful applies trigger the
address-space rebuild pipeline.
- Phase7Applier is constructed here from the resolved sink + a
logger; OpcUaPublishActor takes both.
- Prepends the opcua-synchronized-dispatcher HOCON so the extension
is self-contained — consumers (Host, tests) don't need to redeclare
the dispatcher block.
- New OpcUaPublishActorKey + OpcUaPublishActorName for actor-registry
resolution.
- AddOtOpcUaRuntime now also TryAddSingleton's NullOpcUaAddressSpaceSink
+ NullServiceLevelPublisher so admin-only nodes (or tests that
don't bind the Deferred sink) stay safe.
Host.Program.cs (driver-role only):
- Binds DeferredAddressSpaceSink as singleton + as IOpcUaAddressSpaceSink
- AddHostedService<OtOpcUaServerHostedService>()
Tests: OpcUaServer 24 -> 28 (+4 DeferredAddressSpaceSink unit tests),
Runtime 69 -> 69 (existing ServiceCollectionExtensionsTests extended
to verify the new mux + publish actor registration).
All 6 v2 test suites green: 177 tests passing.
Closes#108. Engine-wiring is now production-bound end-to-end on
driver-role nodes — Deploy reaches real OPC UA Variable nodes that
subscribed clients see.