fix(focas): a stalled device fails fast for the rest of its batch; generation-stamp health (#740 review round 1)

I1: Task.WhenAll waits for the slowest device, so concurrency alone still let a device
that accepts TCP and then stalls cost (its tag count x call timeout) per batch. After the
first timeout, transport failure or comms-class status on a device, its remaining tags in
the batch now fail BadCommunicationError immediately, the same as the coalescer's
FailMembers, which now also stops after a failed range. FIXED: tags are still served
from the cache. A malformed address is BadNodeIdUnknown and does not count as a link
failure. Test: a 10-tag stalled device beside a healthy one completes in under 3 call
timeouts with the healthy value Good. The P9 test now also asserts per-client read
counts and that two reads overlapped across devices.

Minors:
- 1: a superseded init releases its table only if it was never published (flag).
- 2: a fixed-tree refusal credits LastSuccessfulRead; a value-path refusal after a comms
  fault restores Healthy.
- 5: alarm/fixed/refusal health is reset inside the publish lock, after the generation
  check.
- 6: FocasFixedTreeHealthTests wait on served-failure/refusal counters, not wall-clock.
- 8: data-path health writes (reads, coalescer, writes, poll errors, refusals) carry the
  generation they started under and are dropped once a lifecycle call has moved on. Each
  write is a check-and-set under the lifecycle lock.
Also adds a unit case where 20 vendor records with type 0 and empty messages stay vendor.

Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
This commit is contained in:
Joseph Doherty
2026-10-22 14:44:42 -04:00
parent 8ffa6178b5
commit fd64fed217
5 changed files with 335 additions and 86 deletions
@@ -20,11 +20,12 @@ public sealed class FocasConcurrentDeviceReadTests
/// STARTED — so a sequential walk (A first) can never finish A, while a concurrent one does. Also counts
/// the peak number of reads in flight on any one client.
/// </summary>
private sealed class OrderingClient(TaskCompletionSource bStarted) : FakeFocasClient
private sealed class OrderingClient(TaskCompletionSource bStarted, int[] global) : FakeFocasClient
{
private string _host = "";
private int _inFlight;
public int PeakInFlight;
public int Reads;
public override Task ConnectAsync(FocasHostAddress address, TimeSpan timeout, CancellationToken ct)
{
@@ -37,6 +38,9 @@ public sealed class FocasConcurrentDeviceReadTests
{
var now = Interlocked.Increment(ref _inFlight);
InterlockedMax(ref PeakInFlight, now);
Interlocked.Increment(ref Reads);
// global[0] = reads in flight across EVERY client, global[1] = its peak.
InterlockedMax(ref global[1], Interlocked.Increment(ref global[0]));
try
{
if (_host.Contains("10.0.0.6", StringComparison.Ordinal)) bStarted.TrySetResult();
@@ -44,7 +48,11 @@ public sealed class FocasConcurrentDeviceReadTests
await Task.Delay(20, ct).ConfigureAwait(false);
return ((sbyte)1, FocasStatusMapper.Good);
}
finally { Interlocked.Decrement(ref _inFlight); }
finally
{
Interlocked.Decrement(ref _inFlight);
Interlocked.Decrement(ref global[0]);
}
}
private static void InterlockedMax(ref int target, int value)
@@ -60,7 +68,8 @@ public sealed class FocasConcurrentDeviceReadTests
public async Task Devices_are_read_concurrently_and_each_stays_serialised()
{
var bStarted = new TaskCompletionSource(TaskCreationOptions.RunContinuationsAsynchronously);
var factory = new FakeFocasClientFactory { Customise = () => new OrderingClient(bStarted) };
var global = new int[2];
var factory = new FakeFocasClientFactory { Customise = () => new OrderingClient(bStarted, global) };
var drv = new FocasDriver(new FocasDriverOptions
{
Devices = [new FocasDeviceOptions(HostA, DeviceName: "A"), new FocasDeviceOptions(HostB, DeviceName: "B")],
@@ -81,8 +90,66 @@ public sealed class FocasConcurrentDeviceReadTests
snaps.ShouldAllBe(s => s.StatusCode == FocasStatusMapper.Good,
"device A's read can only finish once device B's has started — a sequential walk times A out");
factory.Clients.Count.ShouldBe(2);
factory.Clients.Cast<OrderingClient>().ShouldAllBe(c => c.PeakInFlight == 1,
var clients = factory.Clients.Cast<OrderingClient>().ToList();
// Every client really served reads (2 on A, 1 on B), so "peak 1" is measured, not vacuous …
clients.Select(c => c.Reads).OrderBy(n => n).ShouldBe([1, 2]);
clients.ShouldAllBe(c => c.PeakInFlight == 1,
"one device's socket is still request→response: never two reads in flight on it");
// … and the two devices overlapped: two reads were in flight at once across the clients.
global[1].ShouldBe(2, "the devices must be read at the same time, not one after the other");
await drv.ShutdownAsync(CancellationToken.None);
}
/// <summary>A device that accepted TCP and then stopped answering: every read hangs until the call timeout.</summary>
private sealed class StalledClient : FakeFocasClient
{
public int Reads;
public override async Task<(object? value, uint status)> ReadAsync(
FocasAddress address, FocasDataType type, CancellationToken ct)
{
Interlocked.Increment(ref Reads);
await Task.Delay(Timeout.Infinite, ct).ConfigureAwait(false);
return (null, FocasStatusMapper.Good);
}
}
/// <summary>
/// #740 review I1 — <c>Task.WhenAll</c> waits for the slowest device, so concurrency alone still made a
/// stalled device cost (its tag count × the call timeout) per batch, and the healthy device's values waited
/// that long. After the first timeout on a device its remaining tags in the batch fail fast: the batch is
/// bounded by about ONE call timeout and the healthy device's values are Good.
/// </summary>
[Fact]
public async Task A_stalled_device_costs_one_call_timeout_per_batch_not_one_per_tag()
{
var callTimeout = TimeSpan.FromMilliseconds(200);
var factory = new FakeFocasClientFactory();
factory.Customise = () => factory.Clients.Count == 0 ? new StalledClient() : new FakeFocasClient { Values = { ["R100"] = (sbyte)9 } };
var stalledTags = Enumerable.Range(0, 10)
.Select(i => FocasRawTags.Entry(new FocasTagDefinition($"raw/A{i}", "A", $"R{100 + i}", FocasDataType.Byte)));
var drv = new FocasDriver(new FocasDriverOptions
{
Devices = [new FocasDeviceOptions(HostA, DeviceName: "A"), new FocasDeviceOptions(HostB, DeviceName: "B")],
RawTags = [.. stalledTags, FocasRawTags.Entry(new FocasTagDefinition("raw/B1", "B", "R100", FocasDataType.Byte))],
Probe = new FocasProbeOptions { Enabled = false },
PmcCoalesce = new FocasPmcCoalesceOptions { Enabled = false },
Timeout = callTimeout,
}, "focas-stall", factory);
await drv.InitializeAsync("{}", CancellationToken.None);
// Connect device A first so it gets the stalled client (connect order = client order).
await drv.ReadAsync(["raw/A0"], CancellationToken.None);
var refs = Enumerable.Range(0, 10).Select(i => $"raw/A{i}").Append("raw/B1").ToArray();
var sw = System.Diagnostics.Stopwatch.StartNew();
var snaps = await drv.ReadAsync(refs, CancellationToken.None);
sw.Stop();
sw.Elapsed.ShouldBeLessThan(callTimeout * 3, "one stalled device must cost ~one call timeout, not ten");
snaps[10].StatusCode.ShouldBe(FocasStatusMapper.Good);
snaps[10].Value.ShouldBe((sbyte)9);
snaps.Take(10).ShouldAllBe(s => s.StatusCode == FocasStatusMapper.BadCommunicationError);
((StalledClient)factory.Clients[0]).Reads.ShouldBe(2, "one read in the warm-up batch, one in the measured batch");
await drv.ShutdownAsync(CancellationToken.None);
}