docs(phase4): Modbus Int64/UInt64, FOCAS fail-fast+scaling, Historian Total+dead-letter cap
This commit is contained in:
+29
-5
@@ -78,6 +78,13 @@ The driver picks its client from `Config.Backend`:
|
||||
| `wire` (default) | `WireFocasClient` | Production — pure-managed FOCAS2 over TCP |
|
||||
| `unimplemented` / `none` / `stub` | `UnimplementedFocasClientFactory` | Scaffolding a DriverInstance row before the CNC endpoint is reachable |
|
||||
|
||||
**Fail-fast on `unimplemented` / `none` / `stub`:** a driver instance configured with any of
|
||||
these backends now **faults immediately at `InitializeAsync`** with a clear error message rather
|
||||
than reporting healthy and then failing on the first read/write/subscribe. The driver moves to
|
||||
`Faulted` state and the error is visible on the Admin UI driver-status panel. This is intentional
|
||||
— an operator who forgets to switch to `"wire"` before deploying to production sees a driver
|
||||
fault at startup, not a phantom-healthy driver that silently rejects every request.
|
||||
|
||||
Previous backends (`fwlib`, `fwlib32`, `ipc`) have been retired along
|
||||
with `Driver.FOCAS.Host` and the Fwlib P/Invoke path. Configs that still
|
||||
reference them will throw at startup with a message pointing here.
|
||||
@@ -140,11 +147,26 @@ covers `Spindle/`, `Program/` + `OperationMode/`, `Timers/`, and
|
||||
per-axis `ServoLoad` independently. Identity + `Axes/*` position reads
|
||||
(which every Fanuc CNC supports) are always emitted.
|
||||
|
||||
Position values are scaled integers (matching FOCAS's convention). The
|
||||
managed side exposes them as `Float64` OPC UA nodes; a future
|
||||
`cnc_getfigure` integration will add per-axis decimal scaling. Until
|
||||
then, treat the raw integer as the value the CNC reports and scale on
|
||||
the client side if decimal precision matters.
|
||||
Position values (`AbsolutePosition`, `MachinePosition`, `RelativePosition`, `DistanceToGo`)
|
||||
are CNC-internal scaled integers exposed as `Float64` OPC UA nodes. The driver converts them
|
||||
to engineering units using the per-device `PositionDecimalPlaces` config field (default `0`
|
||||
= no scaling). When set to a positive integer *d*, each position value is divided by `10^d`
|
||||
before publishing, so a CNC that reports millimetres × 1000 is corrected by setting
|
||||
`PositionDecimalPlaces: 3`.
|
||||
|
||||
```jsonc
|
||||
"Devices": [
|
||||
{
|
||||
"HostAddress": "focas://10.20.30.40:8193",
|
||||
"Series": "ThirtyOne_i",
|
||||
"PositionDecimalPlaces": 3 // 123456 → 123.456 mm
|
||||
}
|
||||
]
|
||||
```
|
||||
|
||||
Auto-fetching the decimal-place count via `cnc_getfigure` is deferred (wire-gated). Until
|
||||
that lands, the config field is the authoritative source — consult the MTB / machine
|
||||
parameter sheets for the correct value. Negative values are clamped to `0`.
|
||||
|
||||
**Still user-authored**: `PARAM:6711`, `MACRO:500`, `R100` etc. — specific
|
||||
numbers whose meaning is MTB-specific. Those go under the device folder
|
||||
@@ -221,10 +243,12 @@ latency spike once per cadence.
|
||||
|
||||
| Symptom | Likely cause | Fix |
|
||||
|---------|--------------|-----|
|
||||
| Driver faults immediately at startup with "unimplemented" in the error | `Backend` is `"unimplemented"` / `"none"` / `"stub"` | Change `Backend` to `"wire"` and supply the real CNC endpoint in `Devices[]` |
|
||||
| `BadCommunicationError` on every read | CNC unreachable on TCP:8193 | Check firewall / LAN reachability; FOCAS Ethernet option must be licensed on the CNC side |
|
||||
| Every read returns `BadNotWritable` on writes | Expected — OtOpcUa is read-only against FOCAS | If you actually need writes, open a feature request — the driver's managed wire client doesn't expose the write commands |
|
||||
| `BadOutOfRange` on reads for a macro/parameter | Config address outside the declared `Series` range | Check `docs/v2/focas-version-matrix.md` — either fix the address or widen the `Series` |
|
||||
| Alarm events never fire | `AlarmProjection.Enabled` left at default (false) | Set it to `true` in the driver config |
|
||||
| Axis position values seem 1000× too large | `PositionDecimalPlaces` not set | Add `"PositionDecimalPlaces": 3` (or the MTB-specific value) to the device entry in `Devices[]` |
|
||||
|
||||
## Further reading
|
||||
|
||||
|
||||
@@ -116,3 +116,4 @@ is reproduced in [docs/v2/driver-specs.md §2](../v2/driver-specs.md).
|
||||
- **Wrong-endian readings are silently plausible.** A byte-order misconfiguration produces a wrong number, not a Bad quality code — surface byte-order mismatches as data-validation alerts, not status codes (see [docs/v2/driver-specs.md §2](../v2/driver-specs.md)).
|
||||
- **`WriteOnChangeOnly` + write-only tags** — the suppression cache is only invalidated by a read that returns a divergent value. A tag that is never subscribed/polled never refreshes its cache entry, so a re-asserted value can be suppressed indefinitely. Subscribe every tag that needs deterministic re-writes, or leave the option off.
|
||||
- **Auto-prohibited ranges** are visible via `GetAutoProhibitedRanges` and logged on first occurrence / on clear — use them to find protected register holes in a device's map.
|
||||
- **Int64 / UInt64 OPC UA node DataType** — tags declared with `DataType: Int64` or `DataType: UInt64` advertise the correct OPC UA scalar type (`Int64` / `UInt64`) on their node. Values outside the 32-bit range are preserved end-to-end; the wire codec (4-register read/write) was already correct before this fix.
|
||||
|
||||