docs(ga): G7 PASS - FOCAS live CNC on vd03 (Makino 31i-B), axis tag added via owner-approved deploy e9fbe63e
v2-ci / unit-tests (push) Waiting to run
v2-ci / unit-tests (push) Waiting to run
This commit is contained in:
@@ -137,12 +137,13 @@ v2 GA requires all of the following:
|
||||
- [x] Phase 5 driver complement shipped (Galaxy, Modbus, S7, OpcUaClient, AbCip, AbLegacy, TwinCAT, FOCAS).
|
||||
- [x] Production deployment checklist (separate doc) signed off by Fleet Admin. **G5 SIGNED OFF 2026-11-13** by the owner as Fleet Admin (#615).
|
||||
- [x] At least one end-to-end integration run against the live Galaxy on the dev box succeeds. **G6 PASS 2026-11-12** (#615): windev test Galaxy `DEV` through mxaccessgw `447070a5`; browse (raw + UNS), read, subscribe, write and readback, and native alarm → Part 9 → ack (confirmed in Galaxy) → clear. Evidence: `docs/drivers/evidence/galaxy-g6-e2e-2026-11-12.md`. Found #895 (fixed, `e113faf5`) and #896 (open). DeployWatcher not exercised (no headless Galaxy redeploy).
|
||||
- [ ] FOCAS live-CNC wire-level smoke (#54) runs clean against a real FANUC control.
|
||||
- [x] FOCAS live-CNC wire-level smoke (#54) runs clean against a real FANUC control. **G7 PASS 2026-11-13** on the deployed DEV server (vd03, `76e73e7d`) against the Makino Z-34184 FANUC 31i-B (series G431, version 22.0). Identity, axis `X/AbsolutePosition` (added by owner-approved deploy `e9fbe63e`, a surgical PureAdd), 6 updates in 5 s, and a 2-minute soak with 0 `EW_SOCKET`/`EW_HANDLE`. The identity values were not compared against the control panel. Evidence: `docs/drivers/evidence/focas-g7-2026-11-13/RESULTS.md`.
|
||||
- [x] ~~OPC UA conformance test (CTT or UA Compliance Test Tool) passes against the live endpoint.~~ **G8 WAIVED by the owner 2026-11-13** (#615): no CTT run is required for v2 GA.
|
||||
- [x] Non-transparent redundancy cutover validated with at least one production client (Ignition 8.3 recommended — see decision #85). **G9 PASS 2026-11-13** (#615), with `otopcua-cli` as the client (owner-approved), on an isolated 2-node pair in the deployed `Unset` mode (`003c7f89`): A1–A3, A5, A7, A8, B2 (crash) and B3 pass; A4/A5b are recorded as unmet under `Unset` and met under `Warm` (#717). Evidence: `docs/plans/evidence/2026-11-13-615-g9/RESULTS.md`.
|
||||
|
||||
## Change log
|
||||
|
||||
- **2026-11-13** — **G7 PASS:** a read-only FOCAS live-CNC smoke on vd03 against the Makino Z-34184 31i-B. The owner approved adding one axis tag (`Axes/X/AbsolutePosition`, deploy `e9fbe63e`, surgical PureAdd); it reads 280.1574 Good. The panel comparison was not done (it needs a person at the machine). G1 awaits the owner's decision.
|
||||
- **2026-11-13** — **G2 PASS.** Two full `dotnet test ZB.MOM.WW.OtOpcUa.slnx` runs (60 projects, ~21k tests). One real defect: a bare `"driver"` role literal from #717's `c569f806`, fixed in `f416b883`. Every other failure is environmental and filed: the Modbus fixture is swamped by load (#909), an intermittent opc-plc `BadRequestInterrupted` (#910), and a scripted-alarm run-guard timing test (#911). G1 (stale Phase 6 compliance scripts) and G7 (FOCAS live CNC) evidence is recorded and awaits the owner's decision.
|
||||
- **2026-11-13** — **G5 (#615) signed off** by the owner as Fleet Admin. With G6/G9 passed and G8 waived, every #615 gate is complete and #615 is closed.
|
||||
- **2026-11-13** — **G9 (#615) PASS and G8 waived.** The owner approved `otopcua-cli` as the G9 client and waived the CTT (G8) for GA. G9 ran on an isolated 2-node pair (`otopcua-g9`, `master` `003c7f89`, redundancy mode `Unset` as deployed). ServiceLevel 250/240, a follower stop left the Primary at 250, and ServerArray lists both URIs. On a graceful Primary stop the CLI's `-F` sessions failed over in about 11 s. On a `docker kill` of the Primary they failed over within 1 s, with a ~2 s data gap and no Bad values; the survivor reached 250 at +44 s. The returning node settled at 240 with no failback. A4 (`RedundancySupport`) and A5b (`ServerUriArray`) are unmet under `Unset` and met under `Warm` (#717, closed; enabling Warm is #907). The run found a CLI defect: array values printed as `System.String[]`, fixed by `ValueFormatter`. Evidence: `docs/plans/evidence/2026-11-13-615-g9/RESULTS.md`. G5 (Fleet Admin sign-off) is the only open exit criterion.
|
||||
|
||||