refactor(#655): delete the dead driver-side history capability

HistoryRead is served server-side by IHistorianDataSource; nothing ever dispatched
to a driver's IHistoryProvider. Removes IHistoryProvider, the OpcUaClient history
passthrough, DriverCapability.HistoryRead (+ resilience tier rows and AdminUI row),
HistoryReadStatusException and its node-manager catches, and the tests that only
covered them. Shared result types and HistoryAggregateNotSupportedException stay
(moved to Historian/HistoryReadContracts.cs). A stored ResilienceConfig still
carrying a HistoryRead key parses (diagnostic only; new test).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
This commit is contained in:
Joseph Doherty
2026-10-08 23:34:02 -04:00
parent ca17d2cf71
commit f7d497e532
23 changed files with 149 additions and 1608 deletions
@@ -16,9 +16,8 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.IntegrationTests;
/// <para>
/// <b>Why opc-plc over loopback against our own server</b> — (1) independent
/// cert chain + user-token handling catches interop bugs loopback can't;
/// (2) built-in alarm ConditionType + history simulation gives
/// <see cref="Core.Abstractions.IAlarmSource"/> +
/// <see cref="Core.Abstractions.IHistoryProvider"/> coverage without a custom
/// (2) built-in alarm ConditionType simulation gives
/// <see cref="Core.Abstractions.IAlarmSource"/> coverage without a custom
/// driver fake; (3) pinned image tag fixes the test surface in a way our own
/// evolving server wouldn't. Follow-up: add <c>open62541/open62541</c> as a
/// second image once this lands, for fully-independent-stack interop.
@@ -92,32 +92,4 @@ public sealed class OpcUaClientSmokeTests(OpcPlcFixture sim)
await drv.UnsubscribeAsync(handle, TestContext.Current.CancellationToken);
}
/// <summary>
/// Verifies HistoryReadEvents passthrough issues a well-formed request and returns a
/// result without throwing. opc-plc exposes live alarm conditions (--alm) but is NOT a
/// historian, so the upstream may return zero historical events or reject the service —
/// either way the driver must produce a HistoricalEventsResult, never throw. This proves
/// the wire request + unwrap path; a non-empty event list is infra-gated on an upstream
/// that historizes events.
/// </summary>
[Fact]
public async Task Client_reads_events_returns_result_without_throwing()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
var options = OpcPlcProfile.BuildOptions(sim.EndpointUrl);
await using var drv = new OpcUaClientDriver(options, driverInstanceId: "opcua-smoke-events");
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
var result = await drv.ReadEventsAsync(
sourceName: null, // null → upstream Server object (i=2253)
startUtc: DateTime.UtcNow.AddHours(-1),
endUtc: DateTime.UtcNow,
maxEvents: 100,
cancellationToken: TestContext.Current.CancellationToken);
result.ShouldNotBeNull();
result.Events.ShouldNotBeNull();
}
}