fix(drivers): flip runtime tag parsers to strict enum parsing (#457)
v2-ci / build (pull_request) Successful in 4m12s
v2-ci / unit-tests (pull_request) Failing after 10m15s

R2-11 Phase C. All six equipment-tag parsers (Modbus/S7/AbCip/AbLegacy/
TwinCAT/Focas) now read enum fields via the new TagConfigJson.TryReadEnumStrict:
absent -> fallback, valid -> parsed, present-but-invalid (typo) -> TryParse
returns false -> EquipmentTagRefResolver.TryResolve false -> driver surfaces
BadNodeIdUnknown, instead of the old lenient path that silently defaulted a
typo to a wrong-width Good.

Modbus flips all three enum fields (region/dataType/byteOrder); the other five
flip dataType. The deploy-time Deployment:TagConfigValidationMode=Error gate is
unchanged and remains the operator pre-flight.

Coverage:
- Six *EquipmentTagParserStrictnessTests inverted from Freeze_typo_* (lenient)
  to Typo_*_rejects_the_tag + Valid_*_still_parses.
- TagConfigJsonTests.TryReadEnumStrict_rejects_only_invalid matrix.
- Driver-level end-to-end proof:
  AbCipEquipmentTagTests.Driver_read_of_a_typod_dataType_ref_surfaces_BadNodeIdUnknown
  drives the real AbCipDriver.ReadAsync through resolve->status.

Golden parity corpus has no typo'd enums, so the flip is a no-op there.
Full solution builds clean; all six driver suites + core + parity + gate green.
This commit is contained in:
Joseph Doherty
2026-07-15 11:28:34 -04:00
parent 57003a23a5
commit e8db0a683f
16 changed files with 193 additions and 38 deletions
@@ -5,16 +5,24 @@ using ZB.MOM.WW.OtOpcUa.Driver.FOCAS;
namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Tests;
/// <summary>
/// R2-11 (05/CONV-2 + 05/UNDER-1) strictness surface for the FOCAS equipment-tag parser: lenient
/// runtime freeze on <c>dataType</c>, forced read-only (<c>Writable == false</c> regardless of any
/// authored <c>writable:true</c>), and <c>Inspect</c> reporting the typo + the write-request.
/// R2-11 Phase C (+ 05/UNDER-1) strictness surface for the FOCAS equipment-tag parser: the runtime is now
/// STRICT — a typo'd <c>dataType</c> rejects the tag (<c>TryParse</c> ⇒ <see langword="false"/> ⇒
/// <c>BadNodeIdUnknown</c>); FOCAS tags remain forced read-only (<c>Writable == false</c> regardless of any
/// authored <c>writable:true</c>), and <c>Inspect</c> reports the typo + the write-request.
/// </summary>
public sealed class FocasEquipmentTagParserStrictnessTests
{
[Fact]
public void Freeze_typo_dataType_still_defaults_to_Int32()
public void Typo_dataType_rejects_the_tag()
{
FocasEquipmentTagParser.TryParse("{\"address\":\"D0100\",\"dataType\":\"Int322\"}", out var def)
FocasEquipmentTagParser.TryParse("{\"address\":\"D0100\",\"dataType\":\"Int322\"}", out _)
.ShouldBeFalse();
}
[Fact]
public void Valid_dataType_still_parses()
{
FocasEquipmentTagParser.TryParse("{\"address\":\"D0100\",\"dataType\":\"Int32\"}", out var def)
.ShouldBeTrue();
def.DataType.ShouldBe(FocasDataType.Int32);
}