fix(focas): per-device connect-attempt backoff across the three loops (05/STAB-8)
This commit is contained in:
@@ -0,0 +1,86 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.FOCAS;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Tests;
|
||||
|
||||
/// <summary>
|
||||
/// 05/STAB-8 — a dead FOCAS CNC must not pay a full two-socket reconnect on every tick of each
|
||||
/// read / probe / fixed-tree / recycle loop. The per-device <see cref="ConnectionBackoff"/>
|
||||
/// gates the connect path; the probe bypasses it and a successful connect resets it. No FOCAS
|
||||
/// fixture exists — the fake-client suite is authoritative.
|
||||
/// </summary>
|
||||
[Trait("Category", "Unit")]
|
||||
public sealed class FocasConnectBackoffTests
|
||||
{
|
||||
private static FocasDriverOptions Options(bool probeEnabled) => new()
|
||||
{
|
||||
Devices = [new FocasDeviceOptions("focas://10.0.0.5:8193")],
|
||||
Tags = [new FocasTagDefinition("R", "focas://10.0.0.5:8193", "R100", FocasDataType.Byte)],
|
||||
Probe = new FocasProbeOptions
|
||||
{
|
||||
Enabled = probeEnabled,
|
||||
Interval = TimeSpan.FromMilliseconds(50),
|
||||
Timeout = TimeSpan.FromMilliseconds(250),
|
||||
},
|
||||
// FixedTree / HandleRecycle / AlarmProjection default off — keep only the data path (+ probe).
|
||||
};
|
||||
|
||||
/// <summary>Rapid data calls against a dead CNC attempt a single connect, then fail fast inside the backoff window.</summary>
|
||||
[Fact]
|
||||
public async Task DeadDevice_ConnectAttemptsFollowBackoffSchedule()
|
||||
{
|
||||
var factory = new FakeFocasClientFactory
|
||||
{
|
||||
Customise = () => new FakeFocasClient
|
||||
{
|
||||
ThrowOnConnect = true,
|
||||
Exception = new InvalidOperationException("cnc down"),
|
||||
},
|
||||
};
|
||||
var drv = new FocasDriver(Options(probeEnabled: false), "focas-1", factory);
|
||||
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||
|
||||
for (var i = 0; i < 6; i++)
|
||||
await drv.ReadAsync(["R"], CancellationToken.None);
|
||||
|
||||
// One real connect attempt; the remaining five fail fast inside the window — no new socket
|
||||
// is created (the fake factory records one client per attempted connect).
|
||||
factory.Clients.Count.ShouldBe(1);
|
||||
}
|
||||
|
||||
/// <summary>The probe bypasses the backoff window and a successful connect resets it so the next data call succeeds immediately.</summary>
|
||||
[Fact]
|
||||
public async Task ProbeBypassesBackoff_AndSuccessResets()
|
||||
{
|
||||
var fail = true;
|
||||
var factory = new FakeFocasClientFactory
|
||||
{
|
||||
Customise = () => new FakeFocasClient
|
||||
{
|
||||
ThrowOnConnect = fail,
|
||||
Exception = new InvalidOperationException("cnc down"),
|
||||
},
|
||||
};
|
||||
var drv = new FocasDriver(Options(probeEnabled: true), "focas-1", factory);
|
||||
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||
|
||||
var down = await drv.ReadAsync(["R"], CancellationToken.None);
|
||||
down[0].StatusCode.ShouldBe(FocasStatusMapper.BadCommunicationError);
|
||||
|
||||
// Device recovers. The probe bypasses the still-open window, reconnects, and resets it so
|
||||
// the following data read succeeds with no residual delay.
|
||||
fail = false;
|
||||
var deadline = DateTime.UtcNow + TimeSpan.FromSeconds(3);
|
||||
DataValueSnapshot? good = null;
|
||||
while (DateTime.UtcNow < deadline)
|
||||
{
|
||||
var r = await drv.ReadAsync(["R"], CancellationToken.None);
|
||||
if (r[0].StatusCode == FocasStatusMapper.Good) { good = r[0]; break; }
|
||||
await Task.Delay(25, CancellationToken.None);
|
||||
}
|
||||
|
||||
good.ShouldNotBeNull("probe-driven reconnect must reset the backoff so data reads recover");
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user