feat(drivers): per-driver poll-overrun meter on the shared OtOpcUa Meter; NoteOverrun + backoffCap doc notes
This commit is contained in:
@@ -3,6 +3,7 @@ using System.Collections.Concurrent;
|
||||
using System.Text.Json;
|
||||
using Microsoft.Extensions.Logging;
|
||||
using Microsoft.Extensions.Logging.Abstractions;
|
||||
using ZB.MOM.WW.OtOpcUa.Commons.Observability;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
|
||||
@@ -187,7 +188,12 @@ public sealed class ModbusDriver
|
||||
{
|
||||
if (_cycleBatchItems.TryRemove(handle, out var published) && published.Count > 0)
|
||||
OnDataChangeBatch?.Invoke(this, new DataChangeBatchEventArgs(handle, published));
|
||||
});
|
||||
},
|
||||
// The engine owns no Meter (Core.Abstractions takes no metrics dependency), so this
|
||||
// closure IS the production consumer of its overrun signal.
|
||||
onOverrun: _ => OtOpcUaTelemetry.PollOverruns.Add(1,
|
||||
new KeyValuePair<string, object?>("driver.type", DriverTypeNames.Modbus),
|
||||
new KeyValuePair<string, object?>("driver.instance", driverInstanceId)));
|
||||
}
|
||||
|
||||
/// <summary>Upper bound on the poll-loop failure backoff — adopts the S7-proven 30 s cap fleet-wide (05/STAB-8).</summary>
|
||||
|
||||
Reference in New Issue