feat(heidenhain): Part 9 condition class from alarm class/group, ALARM: selectors in the browse picker, unclaimed alarms counted + logged (#839)
- Core: optional AlarmEventArgs.ConditionClass (AlarmConditionClass Base/Process/Maintenance/System/Safety) carried by NativeAlarmProjector on AlarmConditionSnapshot and written to ConditionClassId/Name by OtOpcUaNodeManager (kept across class-less events, carried across a #641 rebuild). - Heidenhain: HeidenhainAlarmClasses — HEIDENHAIN DNC-interface class/group names (corroborated by the captured iTNC 530 record); class 5 => Safety, group 1/2 => Process, 4/5 => System, else Base. - DiscoverAsync offers AlarmConditions/ selector leaves (IsAlarm Boolean); browse-commit seeds the alarm object. - Alarms no selector claims: otopcua.driver.alarms.unmatched counter, /hosts diagnostics, rate-limited Warning. Refs #839
This commit is contained in:
@@ -122,6 +122,13 @@ public sealed record AlarmAcknowledgeRequest(
|
||||
/// that writes nothing and a host retaining it Active gets a real "Cleared". <c>false</c> (the default, every source that does not
|
||||
/// opt in) keeps every transition's row.
|
||||
/// </param>
|
||||
/// <param name="ConditionClass">
|
||||
/// Optional Part 9 <c>ConditionClass</c> of the condition (lmxopcua#839), for a source whose upstream classifies its
|
||||
/// alarms in a way that maps onto the Part 9 classes with evidence (Heidenhain's error class / group). When set, the
|
||||
/// host writes it to the condition's <c>ConditionClassId</c> / <c>ConditionClassName</c>; <c>null</c> (every other
|
||||
/// source) leaves the node's class untouched — <c>BaseConditionClass</c> ("not modelled") unless an earlier event of
|
||||
/// the same condition set one. A pure annotation: it never moves Active/Acked state and never fires an event on its own.
|
||||
/// </param>
|
||||
public sealed record AlarmEventArgs(
|
||||
IAlarmSubscriptionHandle SubscriptionHandle,
|
||||
string SourceNodeId,
|
||||
@@ -136,7 +143,8 @@ public sealed record AlarmEventArgs(
|
||||
AlarmTransitionKind Kind = AlarmTransitionKind.Unspecified,
|
||||
int? OpcUaSeverity = null,
|
||||
uint? QualityStatusCode = null,
|
||||
bool IsRestatement = false)
|
||||
bool IsRestatement = false,
|
||||
AlarmConditionClass? ConditionClass = null)
|
||||
{
|
||||
/// <summary>
|
||||
/// True when this event only re-annotates the condition's source-data quality — a
|
||||
@@ -163,3 +171,26 @@ public enum AlarmSeverity { Low, Medium, High, Critical }
|
||||
/// Members are append-only: their numeric values must not move.
|
||||
/// </summary>
|
||||
public enum AlarmTransitionKind { Unspecified = 0, Raise, Acknowledge, Clear, Retrigger, ActiveAcknowledged, InactiveUnacknowledged }
|
||||
|
||||
/// <summary>
|
||||
/// The OPC UA Part 9 condition classes (<c>BaseConditionClassType</c> subtypes, Part 9 §5.9) a driver can assign to a
|
||||
/// native condition via <see cref="AlarmEventArgs.ConditionClass"/> (lmxopcua#839). Only the classes a driver has
|
||||
/// evidence for are listed; <see cref="Base"/> is Part 9's "no class modelled". Members are append-only.
|
||||
/// </summary>
|
||||
public enum AlarmConditionClass
|
||||
{
|
||||
/// <summary><c>BaseConditionClassType</c> — the class is not modelled / not known.</summary>
|
||||
Base = 0,
|
||||
|
||||
/// <summary><c>ProcessConditionClassType</c> — the condition relates to the process the system controls.</summary>
|
||||
Process,
|
||||
|
||||
/// <summary><c>MaintenanceConditionClassType</c> — the condition relates to maintenance.</summary>
|
||||
Maintenance,
|
||||
|
||||
/// <summary><c>SystemConditionClassType</c> — the condition relates to the system itself (hardware, software, comms).</summary>
|
||||
System,
|
||||
|
||||
/// <summary><c>SafetyConditionClassType</c> — the condition relates to safety.</summary>
|
||||
Safety,
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user