feat(alarms): condition Quality tracks source connectivity (#477)
Part 9 ConditionType.Quality was never assigned; default(StatusCode)==Good so every native + scripted condition reported Good unconditionally — a comms-lost device still showed a healthy, inactive, Good condition (a wrong-VALUE bug, distinct from the null-value #473/#475). Clients (and HMIs bucketing on IsGood) could not tell "genuinely inactive" from "lost contact". Layer 1 — make Quality a real, plumbed field: - AlarmConditionSnapshot gains OpcUaQuality Quality (default Good). - MaterialiseAlarmCondition sets it (native BadWaitingForInitialData, scripted Good). - WriteAlarmCondition projects snapshot.Quality; the delta-gate gains a Quality member so a quality-bucket change fires a Part 9 event. Layer 2 — drive native quality from driver connectivity (a comms-lost driver emits no alarm transitions, and an alarm-bearing raw tag has no value variable, so quality can't come from either existing channel): - DriverInstanceActor Tells parent ConnectivityChanged on Connected/Reconnecting. - DriverHostActor fans it to every native condition the driver owns as OpcUaPublishActor.AlarmQualityUpdate (Good on connect, Bad on disconnect). - New dedicated IOpcUaAddressSpaceSink.WriteAlarmQuality sets ONLY Quality and fires only on a bucket change — never touches Active/Acked/Retain (an active alarm that loses comms stays active). Not a full-snapshot re-projection, so it can't clobber severity/message and works for a never-fired condition. Forwarded through DeferredAddressSpaceSink (F10b trap; auto-verified by the reflection forwarding guard). Ungated by redundancy role; no /alerts row. Scripted conditions stay Good; worst-of-input quality deferred to #478 (Layer 3). Tests: node-level (materialise/project/no-clobber/unknown-node no-op), NativeAlarmProjector, DriverInstanceActor connectivity emission, DriverHostActor fan-out, OpcUaPublishActor routing, and the wire-level guard (Condition_event_Quality_tracks_source_connectivity_on_the_wire) — RED-verified against a simulated pre-fix always-Good server. Existing DriverInstanceActor parent probes ignore the new ConnectivityChanged. Docs: docs/AlarmTracking.md §"Condition source-data Quality (#477)"; design doc docs/plans/2026-07-17-alarm-condition-quality-477-design.md.
This commit is contained in:
+1
@@ -199,6 +199,7 @@ public sealed class OtOpcUaTelemetryHookTests : RuntimeActorTestBase
|
||||
/// <param name="alarmNodeId">The alarm node identifier.</param>
|
||||
/// <param name="state">The full condition state snapshot.</param>
|
||||
/// <param name="occurredUtc">The time the alarm occurred in UTC.</param>
|
||||
public void WriteAlarmQuality(string alarmNodeId, OpcUaQuality quality, DateTime sourceTimestampUtc, AddressSpaceRealm realm) { }
|
||||
public void WriteAlarmCondition(string alarmNodeId, AlarmConditionSnapshot state, DateTime occurredUtc, AddressSpaceRealm realm = AddressSpaceRealm.Uns) => Writes++;
|
||||
/// <summary>Materialises an alarm condition (stub implementation).</summary>
|
||||
/// <param name="alarmNodeId">The alarm node identifier.</param>
|
||||
|
||||
Reference in New Issue
Block a user