fix(tests,cli): implement IOpcUaAddressSpaceSink.EnsureVariable in test fakes; fix CLI CS1587
v2-ci / build (push) Failing after 44s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped

Resolves the 12 reported build errors (7 CS0535 sink fakes + 5 CLI CS1587).
Runtime.Tests green (74). NOTE: OpcUaServer.Tests still has pre-existing CS7036
errors from the in-progress Galaxy-tag workstream (Phase7Plan/Phase7CompositionResult
new required params) — separate, test-only, not addressed here.
This commit is contained in:
Joseph Doherty
2026-05-29 10:19:32 -04:00
parent 869be660fd
commit da4634d67e
8 changed files with 51 additions and 5 deletions
@@ -12,20 +12,20 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Cli.Commands;
[Command("subscribe", Description = "Watch a PCCC file address via polled subscription until Ctrl+C.")]
public sealed class SubscribeCommand : AbLegacyCommandBase
{
[CommandOption("address", 'a', Description = "PCCC file address — same format as `read`.", IsRequired = true)]
/// <summary>Gets or sets the PCCC file address to subscribe to.</summary>
[CommandOption("address", 'a', Description = "PCCC file address — same format as `read`.", IsRequired = true)]
public string Address { get; init; } = default!;
/// <summary>Gets or sets the data type of the address.</summary>
[CommandOption("type", 't', Description =
"Bit / Int / Long / Float / AnalogInt / String / TimerElement / CounterElement / " +
"ControlElement (default Int).")]
/// <summary>Gets or sets the data type of the address.</summary>
public AbLegacyDataType DataType { get; init; } = AbLegacyDataType.Int;
/// <summary>Gets or sets the polling interval in milliseconds.</summary>
[CommandOption("interval-ms", 'i', Description =
"Publishing interval in milliseconds (default 1000). PollGroupEngine floors " +
"sub-250ms values.")]
/// <summary>Gets or sets the polling interval in milliseconds.</summary>
public int IntervalMs { get; init; } = 1000;
/// <inheritdoc />
@@ -13,14 +13,14 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.S7.Cli.Commands;
[Command("probe", Description = "Verify the S7 endpoint is reachable and a sample read succeeds.")]
public sealed class ProbeCommand : S7CommandBase
{
/// <summary>Gets or sets the S7 address to probe.</summary>
[CommandOption("address", 'a', Description =
"Probe address (default MW0 — merker word 0). DB1.DBW0 if your PLC project " +
"reserves a fingerprint DB.")]
/// <summary>Gets or sets the S7 address to probe.</summary>
public string Address { get; init; } = "MW0";
[CommandOption("type", Description = "Probe data type (default Int16).")]
/// <summary>Gets or sets the data type of the probe address.</summary>
[CommandOption("type", Description = "Probe data type (default Int16).")]
public S7DataType DataType { get; init; } = S7DataType.Int16;
/// <inheritdoc />