Add OPC 40010 Machinery identity columns to the Equipment table (Manufacturer, Model, SerialNumber, HardwareRevision, SoftwareRevision, YearOfConstruction, AssetLocation, ManufacturerUri, DeviceManualUri — all nullable so equipment can be added before identity is fully captured) and surface them via a dedicated Identification panel in the Admin UI Equipment editor. These pair with the new _base equipment-class template seeded in 3yearplan/schemas/classes/_base.json that every other class extends — Manufacturer + Model are declared isRequired: true in the base, the rest optional. Drivers that can read these dynamically (FANUC cnc_sysinfo() returning SoftwareRevision, Beckhoff TwinCAT.SystemInfo, etc.) override the static value at runtime; static value is the operator-set fallback. Exposed on the OPC UA equipment node under the OPC 40010-standard Identification sub-folder per the category → folder mapping in schemas/docs/format-decisions.md D10. Decisions #138 (_base class with extends inheritance, references OPC 40010 + Part 9 + ISO 22400 + handoff canonical state vocabulary) and #139 (Equipment table identity columns) capture the rationale.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -902,6 +902,8 @@ Each step leaves the system runnable. The generic extraction is effectively free
|
||||
| 135 | TwinCAT XAR runs only in a dedicated VM on the integration host; developer machines do NOT run XAR locally | The 7-day trial reactivation needs centralized management; the VM is shared infrastructure. Galaxy is the inverse — runs only on developer machines (Aveva license scoping), not on integration host | 2026-04-17 |
|
||||
| 136 | Consumer cutover (ScadaBridge / Ignition / System Platform IO) is OUT of v2 scope | Owned by a separate integration / operations team. OtOpcUa team's scope ends at Phase 5 (all drivers built, all stability protections in place, full Admin UI shipped including ACL editor). Cutover sequencing, validation methodology, rollback procedures, and Aveva-pattern validation for tier 3 are the integration team's deliverables, tracked in 3-year-plan handoff §"Rollout Posture" and corrections doc §C5 | 2026-04-17 |
|
||||
| 137 | Dev env credentials documented openly in `dev-environment.md`; production uses Integrated Security / gMSA per decision #46 | Dev defaults are not secrets — they're convenience. Production never uses these values; documented separation prevents leakage | 2026-04-17 |
|
||||
| 138 | Every equipment-class template extends a shared `_base` class providing universal cross-machine metadata (identity, state, alarm summary, optional production context) | References OPC UA Companion Spec OPC 40010 (Machinery) for the Identification component + MachineryOperationMode enum, OPC UA Part 9 for alarm summary fields, ISO 22400 for KPI inputs (TotalRunSeconds, TotalCycles), 3-year-plan handoff §"Canonical Model Integration" for the canonical state vocabulary. Inheritance via `extends` field on the equipment-class JSON Schema. Avoids per-class drift in identity / state / alarm field naming and ensures every machine in the estate exposes the same baseline metadata regardless of vendor or protocol. `_base` lives in `3yearplan/schemas/classes/_base.json` (temporary location until the dedicated `schemas` repo is created) | 2026-04-17 |
|
||||
| 139 | Equipment table extended with OPC 40010 identity columns (Manufacturer, Model, SerialNumber, HardwareRevision, SoftwareRevision, YearOfConstruction, AssetLocation, ManufacturerUri, DeviceManualUri) all nullable so equipment can be added before identity is fully captured | First-class columns rather than a JSON blob because these fields are universal (every machine has them) and need to be queryable / searchable in the Admin UI. Manufacturer and Model are declared `isRequired: true` in `_base.json` and the Admin UI flags equipment that lacks them; the rest are optional. Drivers that can read these dynamically (FANUC, Beckhoff, etc.) override the static value at runtime; static value is the fallback. Exposed on the OPC UA node under the OPC 40010-standard `Identification` sub-folder | 2026-04-17 |
|
||||
|
||||