Auto: abcip-1.2 — STRINGnn variant decoding
Closes #226 Adds nullable StringLength to AbCipTagDefinition + AbCipStructureMember so STRING_20 / STRING_40 / STRING_80 UDT variants decode against the right DATA-array capacity. The configured length threads through a new StringMaxCapacity field on AbCipTagCreateParams and lands on the libplctag Tag.StringMaxCapacity attribute (verified property on libplctag 1.5.2). Null leaves libplctag's default 82-byte STRING in place for back-compat. Driver gates on DataType == String so a stray StringLength on a DINT tag doesn't reshape that buffer. UDT member fan-out copies StringLength from the AbCipStructureMember onto the synthesised member tag definition. Tests: 4 new in AbCipDriverReadTests covering threaded StringMaxCapacity, the null back-compat path, the non-String gate, and the UDT-member fan-out.
This commit is contained in:
@@ -92,6 +92,13 @@ public sealed record AbCipDeviceOptions(
|
||||
/// GuardLogix controller; non-safety writes violate the safety-partition isolation and are
|
||||
/// rejected by the PLC anyway. Surfaces the intent explicitly instead of relying on the
|
||||
/// write attempt failing at runtime.</param>
|
||||
/// <param name="StringLength">Capacity of the DATA character array on a Logix STRING / STRINGnn
|
||||
/// UDT — 82 for the stock <c>STRING</c>, 20/40/80/etc for user-defined <c>STRING_20</c>,
|
||||
/// <c>STRING_40</c>, <c>STRING_80</c> variants. Threads through libplctag's
|
||||
/// <c>str_max_capacity</c> attribute so the wrapper allocates the correct backing buffer
|
||||
/// and <c>GetString</c> / <c>SetString</c> truncate at the right boundary. <c>null</c>
|
||||
/// keeps libplctag's default 82-byte STRING behaviour for back-compat. Ignored for
|
||||
/// non-<see cref="AbCipDataType.String"/> types.</param>
|
||||
public sealed record AbCipTagDefinition(
|
||||
string Name,
|
||||
string DeviceHostAddress,
|
||||
@@ -100,7 +107,8 @@ public sealed record AbCipTagDefinition(
|
||||
bool Writable = true,
|
||||
bool WriteIdempotent = false,
|
||||
IReadOnlyList<AbCipStructureMember>? Members = null,
|
||||
bool SafetyTag = false);
|
||||
bool SafetyTag = false,
|
||||
int? StringLength = null);
|
||||
|
||||
/// <summary>
|
||||
/// One declared member of a UDT tag. Name is the member identifier on the PLC (e.g. <c>Speed</c>,
|
||||
@@ -112,7 +120,8 @@ public sealed record AbCipStructureMember(
|
||||
string Name,
|
||||
AbCipDataType DataType,
|
||||
bool Writable = true,
|
||||
bool WriteIdempotent = false);
|
||||
bool WriteIdempotent = false,
|
||||
int? StringLength = null);
|
||||
|
||||
/// <summary>Which AB PLC family the device is — selects the profile applied to connection params.</summary>
|
||||
public enum AbCipPlcFamily
|
||||
|
||||