fix(scripting): give scripted-alarm predicates the configured run budget, not 250 ms (lmxopcua#779)
DriverHostActor built ScriptedAlarmEngine without a scriptTimeout, so every
production alarm predicate fell back to TimedScriptEvaluator.DefaultTimeout
(250 ms) while virtual tags and Calculation tags ran on 2 s. History shows no
decision behind it: 250 ms is the generic Phase-7 A.4 default, the VT
evaluator moved to 2 s in F8b (219d10a2) and the alarm engine was simply never
given a value.
- New node-wide Scripting:RunTimeout (default 2 s, clamped to (0, 60 s],
non-positive -> default, each clamp a startup Warning) on ScriptingOptions.
- The VT evaluator and the alarm engine default to it; DriverHostActor now
builds the engine through CreateScriptedAlarmEngine, which passes it
explicitly. Calculation keeps its per-driver runTimeoutMs.
- Docs: ScriptEditor (config table), ScriptedAlarms, VirtualTags.
Tests: ScriptedAlarmEngineBudgetTests (a 600 ms predicate now completes and
activates; default and configured budgets), ScriptedAlarmEngineBudgetWiringTests
(the host-built engine), ScriptingOptionsBindingTests (bind + clamps). The
engine and wiring tests fail with the old 250 ms default restored.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
This commit is contained in:
@@ -1248,14 +1248,34 @@ public sealed class DriverHostActor : ReceiveActor, IWithTimers, IWithUnboundedS
|
||||
() =>
|
||||
{
|
||||
var upstream = new DependencyMuxTagUpstreamSource();
|
||||
var engine = new ScriptedAlarmEngine(
|
||||
upstream, store, new ScriptLoggerFactory(scriptLogger), scriptLogger, scripting: scripting);
|
||||
return (upstream, engine);
|
||||
return (upstream, CreateScriptedAlarmEngine(upstream, store, scriptLogger, scripting));
|
||||
},
|
||||
_localNode, telemetryHub: _telemetryHub),
|
||||
"scripted-alarm-host");
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Builds the scripted-alarm engine the alarm host owns, with the node's <c>Scripting:RunTimeout</c> as the
|
||||
/// per-predicate budget. lmxopcua#779: the engine used to be built without a budget and fell back to the
|
||||
/// 250 ms <c>TimedScriptEvaluator.DefaultTimeout</c>, an eighth of what a virtual tag reading the same
|
||||
/// inputs gets. Passed explicitly (not left to the engine's own null default) so the host is the one place
|
||||
/// that decides it.
|
||||
/// </summary>
|
||||
/// <param name="upstream">The engine's upstream tag source.</param>
|
||||
/// <param name="store">The condition-state store.</param>
|
||||
/// <param name="scriptLogger">The root script logger.</param>
|
||||
/// <param name="scripting">The node-wide <c>Scripting</c> options; null ⇒ defaults.</param>
|
||||
/// <returns>A new, unloaded engine.</returns>
|
||||
internal static ScriptedAlarmEngine CreateScriptedAlarmEngine(
|
||||
ZB.MOM.WW.OtOpcUa.Core.ScriptedAlarms.ITagUpstreamSource upstream, IAlarmStateStore store,
|
||||
Serilog.ILogger scriptLogger, ScriptingOptions? scripting)
|
||||
{
|
||||
var budget = (scripting ?? new ScriptingOptions()).Sanitized(out _).RunTimeout;
|
||||
return new ScriptedAlarmEngine(
|
||||
upstream, store, new ScriptLoggerFactory(scriptLogger), scriptLogger,
|
||||
scriptTimeout: budget, scripting: scripting);
|
||||
}
|
||||
|
||||
private void Bootstrap()
|
||||
{
|
||||
// Per-cluster mesh Phase 3: a FetchAndCache node NEVER reads central SQL for config, at boot
|
||||
|
||||