Merge pull request '[s7] S7 — TSAP / Connection Type selector' (#375) from auto/s7/PR-S7-C2 into auto/driver-gaps
This commit was merged in pull request #375.
This commit is contained in:
@@ -22,6 +22,9 @@ dotnet run --project src/ZB.MOM.WW.OtOpcUa.Driver.S7.Cli -- --help
|
||||
| `--rack` | `0` | Hardware rack (S7-400 distributed setups only) |
|
||||
| `--slot` | `0` | CPU slot (S7-300 = 2, S7-400 = 2 or 3, S7-1200/1500 = 0) |
|
||||
| `--timeout-ms` | `5000` | Per-operation timeout |
|
||||
| `--tsap-mode` | `Auto` | ISO-on-TCP connection class: `Auto` / `Pg` / `Op` / `S7Basic` / `Other`. Hardened S7-1500 / ET 200SP CPUs may require `Op` or `S7Basic`. See [s7.md TSAP / Connection Type](v2/s7.md#tsap--connection-type). |
|
||||
| `--local-tsap` | (unset) | Optional 16-bit local TSAP override (e.g. `0x0200`). Required when `--tsap-mode Other`; wins over class default under Pg/Op/S7Basic. |
|
||||
| `--remote-tsap` | (unset) | Optional 16-bit remote TSAP override. Required when `--tsap-mode Other`; wins over class default under Pg/Op/S7Basic. |
|
||||
| `--verbose` | off | Serilog debug output |
|
||||
|
||||
## PUT/GET must be enabled
|
||||
@@ -83,6 +86,26 @@ otopcua-s7-cli write -h 192.168.1.30 -a M0.0 -t Bool -v true
|
||||
**Writes to M / Q are real** — they drive the PLC program. Be careful what you
|
||||
flip on a running machine.
|
||||
|
||||
### Hardened CPU — forcing OP-class TSAP
|
||||
|
||||
```powershell
|
||||
# Probe a hardened S7-1500 that rejects PG class but accepts OP.
|
||||
otopcua-s7-cli probe -h 10.50.12.30 --tsap-mode Op
|
||||
|
||||
# Read against the same CPU.
|
||||
otopcua-s7-cli read -h 10.50.12.30 --tsap-mode Op -a DB1.DBW0 -t Int16
|
||||
|
||||
# Manual TSAP override (e.g. site with a fixed proprietary TSAP gateway).
|
||||
otopcua-s7-cli probe -h 10.50.12.30 --tsap-mode Other --local-tsap 0x4D57 --remote-tsap 0x4D58
|
||||
```
|
||||
|
||||
Without `--tsap-mode`, the CLI uses S7netplus's CpuType-derived default (PG
|
||||
class for almost everything). The same connection-refused failure shape that a
|
||||
wrong `--slot` produces also shows up when the CPU rejects PG class — try
|
||||
`--tsap-mode Op` first when the handshake is failing on otherwise-correct
|
||||
endpoint config. See [s7.md TSAP / Connection Type](v2/s7.md#tsap--connection-type)
|
||||
for the byte table and motivation.
|
||||
|
||||
### `subscribe`
|
||||
|
||||
```powershell
|
||||
|
||||
@@ -573,6 +573,86 @@ S7 driver health without reaching for a Wireshark capture:
|
||||
The values render alongside Modbus / OPC UA Client metrics in the Admin
|
||||
UI driver-diagnostics panel — same RPC, same dashboard row layout.
|
||||
|
||||
## TSAP / Connection Type
|
||||
|
||||
S7comm runs on top of ISO-on-TCP (RFC 1006), and the COTP connection-request
|
||||
PDU carries a 16-bit **TSAP pair** (local + remote) that the CPU validates
|
||||
before any S7comm payload flows. S7netplus's default `Plc(CpuType, host, port,
|
||||
rack, slot)` constructor picks a **PG-class** TSAP pair via
|
||||
`TsapPair.GetDefaultTsapPair`. That choice works against most lab S7-1200 /
|
||||
S7-1500 CPUs and against TIA Portal itself, but **hardened deployments**
|
||||
(security-config'd S7-1500, ET 200SP, locked-down PROFINET projects) reject
|
||||
PG class outright at COTP-handshake time, returning the same connection-refused
|
||||
shape as a wrong slot byte.
|
||||
|
||||
PR-S7-C2 surfaces a `TsapMode` enum on `S7DriverOptions` so an operator can
|
||||
force a specific class without re-flashing the PLC project. It applies equally
|
||||
to the Admin-UI-driven config DB row and to the `otopcua-s7-cli` test client.
|
||||
|
||||
### Raw-TSAP byte table
|
||||
|
||||
The high byte is the connection class. The local low byte is conventionally
|
||||
`0x00` (caller / unprivileged), and the remote low byte is
|
||||
`(rack << 5) | slot` per the S7 spec — the same convention S7netplus's
|
||||
`TsapPair.GetDefaultTsapPair(CpuType, rack, slot)` uses for the remote endpoint.
|
||||
|
||||
| Class | High byte | Local TSAP (rack=0/slot=0) | Remote TSAP (rack=0/slot=0) | Remote TSAP (rack=0/slot=2) | Typical use |
|
||||
|----------|-----------|----------------------------|------------------------------|------------------------------|----------------------------------------------|
|
||||
| PG | `0x01` | `0x0100` | `0x0100` | `0x0102` | TIA Portal, dev laptops, lab S7-1200/1500 |
|
||||
| OP | `0x02` | `0x0200` | `0x0200` | `0x0202` | Operator panels, hardened-CPU S7-1500 |
|
||||
| S7-Basic | `0x03` | `0x0300` | `0x0300` | `0x0302` | WinCC BasicPanel SDK, S7-Basic clients |
|
||||
| Other | caller | caller-supplied | caller-supplied | caller-supplied | escape hatch — unusual fixed-TSAP firmware |
|
||||
|
||||
### `TsapMode` enum
|
||||
|
||||
| Mode | Behaviour |
|
||||
|-----------|----------------------------------------------------------------------------------------------------------------------------------|
|
||||
| `Auto` | Existing behaviour — S7netplus picks the TSAP pair from `CpuType`. Explicit `LocalTsap` / `RemoteTsap` are ignored under `Auto`. |
|
||||
| `Pg` | Force PG class (high byte `0x01`). Local / remote computed from rack + slot. |
|
||||
| `Op` | Force OP class (high byte `0x02`). |
|
||||
| `S7Basic` | Force S7-Basic class (high byte `0x03`). |
|
||||
| `Other` | Caller-supplied `LocalTsap` + `RemoteTsap`. Both must be set or driver init throws `InvalidOperationException`. |
|
||||
|
||||
Explicit `LocalTsap` / `RemoteTsap` overrides win over the class-derived
|
||||
defaults under any non-`Auto` mode — a site that needs a fixed source-TSAP for
|
||||
firewall reasons can pin `LocalTsap` while keeping `TsapMode = Pg` for the
|
||||
remote computation.
|
||||
|
||||
### Worked example: hardened S7-1500 requiring OP class
|
||||
|
||||
```jsonc
|
||||
{
|
||||
"Host": "10.50.12.30",
|
||||
"CpuType": "S71500",
|
||||
"Rack": 0,
|
||||
"Slot": 0,
|
||||
"TsapMode": "Op",
|
||||
"Tags": [ /* … */ ]
|
||||
}
|
||||
```
|
||||
|
||||
This produces local = `0x0200`, remote = `0x0200` (rack=0, slot=0). The same
|
||||
PLC under `TsapMode = "Auto"` (PG class) returns COTP rejection — same packet
|
||||
capture shape as a wrong-slot misconfig, which is the failure-mode footnote
|
||||
under §5 of `driver-specs.md`.
|
||||
|
||||
### Why not just expose `LocalTsap` / `RemoteTsap` directly?
|
||||
|
||||
Most operators don't know the byte format off-hand and reach for `Pg` /
|
||||
`Op` / `S7Basic` based on Siemens-doc terminology. Keeping the enum lets the
|
||||
Admin UI render a dropdown with sensible labels, while the `ushort?` fields
|
||||
stay available as the manual escape hatch when a site has truly unusual
|
||||
firmware (e.g. third-party S7-protocol gateways with fixed proprietary
|
||||
TSAPs). Both paths are exercised in the unit-test mapping table.
|
||||
|
||||
### Live-firmware verification
|
||||
|
||||
The PG/OP/S7-Basic byte table above is the documented Siemens convention; the
|
||||
actual handshake is verified against the dev-box S7-1500 lab rig (a hardened
|
||||
project that rejects PG and accepts OP). That test is documented in
|
||||
`tests/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests` but only runs against
|
||||
real firmware — the pymodbus-style "TSAP simulator" doesn't exist for S7.
|
||||
|
||||
## References
|
||||
|
||||
1. Siemens Industry Online Support, *Modbus/TCP Communication between SIMATIC S7-1500 / S7-1200 and Modbus/TCP Controllers with Instructions `MB_CLIENT` and `MB_SERVER`*, Entry ID 102020340, V6 (Feb 2021). https://cache.industry.siemens.com/dl/files/340/102020340/att_118119/v6/net_modbus_tcp_s7-1500_s7-1200_en.pdf
|
||||
|
||||
@@ -33,6 +33,23 @@ public abstract class S7CommandBase : DriverCommandBase
|
||||
[CommandOption("timeout-ms", Description = "Per-operation timeout in ms (default 5000).")]
|
||||
public int TimeoutMs { get; init; } = 5000;
|
||||
|
||||
[CommandOption("tsap-mode", Description =
|
||||
"ISO-on-TCP / S7comm connection class: Auto (default — S7netplus picks the TSAP " +
|
||||
"from --cpu), Pg, Op, S7Basic, or Other (requires --local-tsap and --remote-tsap). " +
|
||||
"Hardened S7-1500 / ET 200SP CPUs may refuse PG and require Op or S7Basic. See " +
|
||||
"docs/v2/s7.md \"TSAP / Connection Type\" for the byte table and motivation.")]
|
||||
public TsapMode TsapMode { get; init; } = TsapMode.Auto;
|
||||
|
||||
[CommandOption("local-tsap", Description =
|
||||
"Optional 16-bit local TSAP override (e.g. 0x4D57). Required when --tsap-mode is Other; " +
|
||||
"wins over the class default under Pg/Op/S7Basic.")]
|
||||
public ushort? LocalTsap { get; init; }
|
||||
|
||||
[CommandOption("remote-tsap", Description =
|
||||
"Optional 16-bit remote TSAP override. Required when --tsap-mode is Other; wins over " +
|
||||
"the class default under Pg/Op/S7Basic.")]
|
||||
public ushort? RemoteTsap { get; init; }
|
||||
|
||||
/// <inheritdoc />
|
||||
public override TimeSpan Timeout
|
||||
{
|
||||
@@ -55,6 +72,9 @@ public abstract class S7CommandBase : DriverCommandBase
|
||||
Timeout = Timeout,
|
||||
Tags = tags,
|
||||
Probe = new S7ProbeOptions { Enabled = false },
|
||||
TsapMode = TsapMode,
|
||||
LocalTsap = LocalTsap,
|
||||
RemoteTsap = RemoteTsap,
|
||||
};
|
||||
|
||||
protected string DriverInstanceId => $"s7-cli-{Host}:{Port}";
|
||||
|
||||
@@ -163,7 +163,7 @@ public sealed class S7Driver(S7DriverOptions options, string driverInstanceId)
|
||||
_parsedByName[t.Name] = parsed;
|
||||
}
|
||||
|
||||
var plc = new Plc(_options.CpuType, _options.Host, _options.Port, _options.Rack, _options.Slot);
|
||||
var plc = BuildPlc();
|
||||
// S7netplus writes timeouts into the underlying TcpClient via Plc.WriteTimeout /
|
||||
// Plc.ReadTimeout (milliseconds). Set before OpenAsync so the handshake itself
|
||||
// honours the bound.
|
||||
@@ -889,6 +889,58 @@ public sealed class S7Driver(S7DriverOptions options, string driverInstanceId)
|
||||
private global::S7.Net.Plc RequirePlc() =>
|
||||
Plc ?? throw new InvalidOperationException("S7Driver not initialized");
|
||||
|
||||
/// <summary>
|
||||
/// Construct the underlying S7netplus <see cref="Plc"/> honouring
|
||||
/// <see cref="S7DriverOptions.TsapMode"/>, <see cref="S7DriverOptions.LocalTsap"/>,
|
||||
/// and <see cref="S7DriverOptions.RemoteTsap"/>. <see cref="TsapMode.Auto"/> falls
|
||||
/// back to the existing <c>(CpuType, host, port, rack, slot)</c> constructor so the
|
||||
/// change is opt-in for sites that don't need a non-default class. Other modes go
|
||||
/// through the raw-TSAP-pair overload, computing the pair from
|
||||
/// <see cref="S7TsapDefaults"/> and the configured rack/slot, then layering the
|
||||
/// caller-supplied <see cref="S7DriverOptions.LocalTsap"/> /
|
||||
/// <see cref="S7DriverOptions.RemoteTsap"/> on top.
|
||||
/// </summary>
|
||||
private Plc BuildPlc()
|
||||
{
|
||||
if (_options.TsapMode == TsapMode.Auto)
|
||||
{
|
||||
// Existing behaviour: S7netplus picks the TSAP pair via TsapPair.GetDefaultTsapPair
|
||||
// from CpuType + rack + slot. An explicit LocalTsap / RemoteTsap under Auto is
|
||||
// ignored on purpose — Auto means "let the library decide". Document this in s7.md.
|
||||
return new Plc(_options.CpuType, _options.Host, _options.Port, _options.Rack, _options.Slot);
|
||||
}
|
||||
|
||||
ushort localTsap;
|
||||
ushort remoteTsap;
|
||||
|
||||
if (_options.TsapMode == TsapMode.Other)
|
||||
{
|
||||
if (_options.LocalTsap is not ushort lt || _options.RemoteTsap is not ushort rt)
|
||||
{
|
||||
throw new InvalidOperationException(
|
||||
"S7DriverOptions.TsapMode = Other requires both LocalTsap and RemoteTsap to be set " +
|
||||
"(no class default exists for Other). Set both, or pick Pg / Op / S7Basic.");
|
||||
}
|
||||
localTsap = lt;
|
||||
remoteTsap = rt;
|
||||
}
|
||||
else
|
||||
{
|
||||
var classByte = S7TsapDefaults.HighByteFor(_options.TsapMode);
|
||||
// Compute defaults from the class + configured rack/slot, then let explicit
|
||||
// overrides win — so e.g. "TsapMode = Pg, LocalTsap = 0x0142" produces a PG-class
|
||||
// remote with a custom local for sites that need a fixed source-TSAP.
|
||||
localTsap = _options.LocalTsap ?? S7TsapDefaults.BuildLocalTsap(classByte);
|
||||
remoteTsap = _options.RemoteTsap ?? S7TsapDefaults.BuildRemoteTsap(
|
||||
classByte, _options.Rack, _options.Slot);
|
||||
}
|
||||
|
||||
var pair = new global::S7.Net.Protocol.TsapPair(
|
||||
new global::S7.Net.Protocol.Tsap((byte)(localTsap >> 8), (byte)(localTsap & 0xFF)),
|
||||
new global::S7.Net.Protocol.Tsap((byte)(remoteTsap >> 8), (byte)(remoteTsap & 0xFF)));
|
||||
return new Plc(_options.Host, _options.Port, pair);
|
||||
}
|
||||
|
||||
// ---- ITagDiscovery ----
|
||||
|
||||
public Task DiscoverAsync(IAddressSpaceBuilder builder, CancellationToken cancellationToken)
|
||||
|
||||
@@ -53,6 +53,10 @@ public static class S7DriverFactoryExtensions
|
||||
Timeout = TimeSpan.FromMilliseconds(dto.Probe?.TimeoutMs ?? 2_000),
|
||||
ProbeAddress = dto.Probe?.ProbeAddress ?? "MW0",
|
||||
},
|
||||
TsapMode = ParseEnum<TsapMode>(dto.TsapMode, driverInstanceId, "TsapMode",
|
||||
fallback: TsapMode.Auto),
|
||||
LocalTsap = dto.LocalTsap,
|
||||
RemoteTsap = dto.RemoteTsap,
|
||||
};
|
||||
|
||||
return new S7Driver(options, driverInstanceId);
|
||||
@@ -103,6 +107,21 @@ public static class S7DriverFactoryExtensions
|
||||
public int? TimeoutMs { get; init; }
|
||||
public List<S7TagDto>? Tags { get; init; }
|
||||
public S7ProbeDto? Probe { get; init; }
|
||||
|
||||
/// <summary>
|
||||
/// Optional connection-class selector — one of <c>Auto</c> (default),
|
||||
/// <c>Pg</c>, <c>Op</c>, <c>S7Basic</c>, <c>Other</c>. When omitted the driver
|
||||
/// keeps the existing <c>Auto</c> behaviour (S7netplus picks the TSAP pair
|
||||
/// from <see cref="CpuType"/>). See <c>docs/v2/s7.md</c> "TSAP / Connection
|
||||
/// Type" section.
|
||||
/// </summary>
|
||||
public string? TsapMode { get; init; }
|
||||
|
||||
/// <summary>Optional 16-bit local TSAP override. Required (with <see cref="RemoteTsap"/>) when <c>TsapMode = Other</c>.</summary>
|
||||
public ushort? LocalTsap { get; init; }
|
||||
|
||||
/// <summary>Optional 16-bit remote TSAP override. Required (with <see cref="LocalTsap"/>) when <c>TsapMode = Other</c>.</summary>
|
||||
public ushort? RemoteTsap { get; init; }
|
||||
}
|
||||
|
||||
internal sealed class S7TagDto
|
||||
|
||||
@@ -81,6 +81,111 @@ public sealed class S7DriverOptions
|
||||
/// opt out of merging regardless of this knob.
|
||||
/// </remarks>
|
||||
public int BlockCoalescingGapBytes { get; init; } = S7BlockCoalescingPlanner.DefaultGapMergeBytes;
|
||||
|
||||
/// <summary>
|
||||
/// ISO-on-TCP / S7comm "connection class" selector. Hardened S7-1500 CPUs and some
|
||||
/// ET 200SP / S7-1200 firmware variants reject the default <b>PG-class</b> TSAP that
|
||||
/// S7netplus picks under <see cref="TsapMode.Auto"/> and require an <b>OP-class</b>
|
||||
/// or <b>S7-Basic-class</b> TSAP instead. Picking the wrong class produces the same
|
||||
/// failure shape as picking the wrong slot — connection refused at COTP handshake
|
||||
/// time, before any S7comm PDU is sent. See <c>docs/v2/s7.md</c> "TSAP / Connection
|
||||
/// Type" section for the raw-TSAP byte table and the hardened-CPU motivation.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <para>
|
||||
/// <see cref="TsapMode.Auto"/> preserves existing behaviour — S7netplus picks
|
||||
/// the TSAP pair from the configured <see cref="CpuType"/> via its
|
||||
/// <c>TsapPair.GetDefaultTsapPair</c>. Use <see cref="TsapMode.Pg"/> /
|
||||
/// <see cref="TsapMode.Op"/> / <see cref="TsapMode.S7Basic"/> to force a specific
|
||||
/// class, or <see cref="TsapMode.Other"/> together with <see cref="LocalTsap"/>
|
||||
/// and <see cref="RemoteTsap"/> for a fully-manual escape hatch. Explicit
|
||||
/// <see cref="LocalTsap"/> / <see cref="RemoteTsap"/> overrides win even under
|
||||
/// <see cref="TsapMode.Pg"/> / <see cref="TsapMode.Op"/> / <see cref="TsapMode.S7Basic"/>.
|
||||
/// </para>
|
||||
/// </remarks>
|
||||
public TsapMode TsapMode { get; init; } = TsapMode.Auto;
|
||||
|
||||
/// <summary>
|
||||
/// Optional fully-manual local TSAP override (16-bit big-endian word — high byte =
|
||||
/// class selector, low byte = caller-defined). Required (together with
|
||||
/// <see cref="RemoteTsap"/>) when <see cref="TsapMode"/> is
|
||||
/// <see cref="TsapMode.Other"/>. Wins over the class-derived default under any
|
||||
/// non-<see cref="TsapMode.Auto"/> mode.
|
||||
/// </summary>
|
||||
public ushort? LocalTsap { get; init; }
|
||||
|
||||
/// <summary>
|
||||
/// Optional fully-manual remote TSAP override (16-bit big-endian word — high byte =
|
||||
/// class selector, low byte = <c>(rack << 5) | slot</c> per the S7 spec).
|
||||
/// Required (together with <see cref="LocalTsap"/>) when <see cref="TsapMode"/> is
|
||||
/// <see cref="TsapMode.Other"/>. Wins over the class-derived default under any
|
||||
/// non-<see cref="TsapMode.Auto"/> mode.
|
||||
/// </summary>
|
||||
public ushort? RemoteTsap { get; init; }
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// ISO-on-TCP / S7comm connection class. Picks the high byte of the TSAP pair used
|
||||
/// during COTP handshake. See <c>docs/v2/s7.md</c> "TSAP / Connection Type" section
|
||||
/// for the raw-byte table and the hardened-CPU motivation.
|
||||
/// </summary>
|
||||
public enum TsapMode
|
||||
{
|
||||
/// <summary>S7netplus picks the TSAP pair from <see cref="S7DriverOptions.CpuType"/>. Existing behaviour.</summary>
|
||||
Auto,
|
||||
/// <summary>PG class — high byte 0x01. Default for development laptops / TIA Portal.</summary>
|
||||
Pg,
|
||||
/// <summary>OP class — high byte 0x02. Required by some hardened S7-1500 / ET 200SP deployments.</summary>
|
||||
Op,
|
||||
/// <summary>S7-Basic class — high byte 0x03. Used by S7-Basic clients (e.g. some HMI panels and the WinCC BasicPanel SDK).</summary>
|
||||
S7Basic,
|
||||
/// <summary>Caller-supplied <see cref="S7DriverOptions.LocalTsap"/> + <see cref="S7DriverOptions.RemoteTsap"/>. Both must be set or driver init throws.</summary>
|
||||
Other,
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Raw-TSAP byte constants per ISO-on-TCP / S7comm connection class. The "high byte"
|
||||
/// is the class selector documented in the Siemens function manual; the local TSAP's
|
||||
/// low byte is conventionally 0x00 (caller / unprivileged) and the remote TSAP's low
|
||||
/// byte is <c>(rack << 5) | slot</c> per the spec. Mirrored in
|
||||
/// <c>docs/v2/s7.md</c> "TSAP / Connection Type" table.
|
||||
/// </summary>
|
||||
public static class S7TsapDefaults
|
||||
{
|
||||
/// <summary>PG-class high byte = 0x01.</summary>
|
||||
public const byte PgClassHighByte = 0x01;
|
||||
|
||||
/// <summary>OP-class high byte = 0x02.</summary>
|
||||
public const byte OpClassHighByte = 0x02;
|
||||
|
||||
/// <summary>S7-Basic-class high byte = 0x03.</summary>
|
||||
public const byte S7BasicClassHighByte = 0x03;
|
||||
|
||||
/// <summary>Build the local TSAP (16-bit BE): <c>class << 8 | 0x00</c>.</summary>
|
||||
public static ushort BuildLocalTsap(byte classHighByte) => (ushort)(classHighByte << 8);
|
||||
|
||||
/// <summary>
|
||||
/// Build the remote TSAP (16-bit BE): <c>class << 8 | ((rack & 0x07) << 5 | (slot & 0x1F))</c>.
|
||||
/// Matches the convention used by S7netplus's <c>TsapPair.GetDefaultTsapPair</c> for the remote endpoint.
|
||||
/// </summary>
|
||||
public static ushort BuildRemoteTsap(byte classHighByte, int rack, int slot)
|
||||
{
|
||||
if (rack < 0 || rack > 15)
|
||||
throw new ArgumentOutOfRangeException(nameof(rack), rack, "rack must be 0..15");
|
||||
if (slot < 0 || slot > 31)
|
||||
throw new ArgumentOutOfRangeException(nameof(slot), slot, "slot must be 0..31");
|
||||
return (ushort)((classHighByte << 8) | ((rack & 0x07) << 5) | (slot & 0x1F));
|
||||
}
|
||||
|
||||
/// <summary>Pick the class high-byte for a non-<see cref="TsapMode.Auto"/> / non-<see cref="TsapMode.Other"/> mode.</summary>
|
||||
public static byte HighByteFor(TsapMode mode) => mode switch
|
||||
{
|
||||
TsapMode.Pg => PgClassHighByte,
|
||||
TsapMode.Op => OpClassHighByte,
|
||||
TsapMode.S7Basic => S7BasicClassHighByte,
|
||||
_ => throw new ArgumentOutOfRangeException(nameof(mode), mode,
|
||||
"HighByteFor only handles Pg / Op / S7Basic; Auto and Other are caller-handled"),
|
||||
};
|
||||
}
|
||||
|
||||
public sealed class S7ProbeOptions
|
||||
|
||||
213
tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/S7TsapModeTests.cs
Normal file
213
tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/S7TsapModeTests.cs
Normal file
@@ -0,0 +1,213 @@
|
||||
using System.Text.Json;
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.S7.Tests;
|
||||
|
||||
/// <summary>
|
||||
/// Unit tests for the PR-S7-C2 TSAP / Connection Type selector. Validates the
|
||||
/// <see cref="S7TsapDefaults"/> raw-byte mapping, the <see cref="TsapMode"/> →
|
||||
/// constructor branching in <see cref="S7Driver"/>, and JSON DTO round-trip on
|
||||
/// <see cref="S7DriverFactoryExtensions"/>. The live-PLC handshake is exercised
|
||||
/// separately (and is hardware-gated to the dev-box S7-1500 lab rig).
|
||||
/// </summary>
|
||||
[Trait("Category", "Unit")]
|
||||
public sealed class S7TsapModeTests
|
||||
{
|
||||
[Fact]
|
||||
public void Default_TsapMode_is_Auto_to_preserve_existing_behaviour()
|
||||
{
|
||||
new S7DriverOptions().TsapMode.ShouldBe(TsapMode.Auto);
|
||||
new S7DriverOptions().LocalTsap.ShouldBeNull();
|
||||
new S7DriverOptions().RemoteTsap.ShouldBeNull();
|
||||
}
|
||||
|
||||
// ---- High-byte mapping ----
|
||||
|
||||
[Theory]
|
||||
[InlineData(TsapMode.Pg, S7TsapDefaults.PgClassHighByte)]
|
||||
[InlineData(TsapMode.Op, S7TsapDefaults.OpClassHighByte)]
|
||||
[InlineData(TsapMode.S7Basic, S7TsapDefaults.S7BasicClassHighByte)]
|
||||
public void HighByteFor_returns_the_class_selector_for_each_named_mode(TsapMode mode, byte expected)
|
||||
{
|
||||
S7TsapDefaults.HighByteFor(mode).ShouldBe(expected);
|
||||
}
|
||||
|
||||
[Theory]
|
||||
[InlineData(TsapMode.Auto)]
|
||||
[InlineData(TsapMode.Other)]
|
||||
public void HighByteFor_throws_for_Auto_and_Other(TsapMode mode)
|
||||
{
|
||||
Should.Throw<ArgumentOutOfRangeException>(() => S7TsapDefaults.HighByteFor(mode));
|
||||
}
|
||||
|
||||
// ---- Raw-byte construction ----
|
||||
|
||||
[Theory]
|
||||
[InlineData(S7TsapDefaults.PgClassHighByte, 0x0100)]
|
||||
[InlineData(S7TsapDefaults.OpClassHighByte, 0x0200)]
|
||||
[InlineData(S7TsapDefaults.S7BasicClassHighByte, 0x0300)]
|
||||
public void BuildLocalTsap_uses_class_high_byte_with_zero_low_byte(byte cls, ushort expected)
|
||||
{
|
||||
S7TsapDefaults.BuildLocalTsap(cls).ShouldBe(expected);
|
||||
}
|
||||
|
||||
[Theory]
|
||||
// PG / S7-300 default — rack=0 slot=2 → 0x0102 (matches docs/v2/s7.md table).
|
||||
[InlineData(S7TsapDefaults.PgClassHighByte, 0, 2, 0x0102)]
|
||||
// OP / S7-300 default — rack=0 slot=2 → 0x0202.
|
||||
[InlineData(S7TsapDefaults.OpClassHighByte, 0, 2, 0x0202)]
|
||||
// S7-Basic / S7-300 default — rack=0 slot=2 → 0x0302.
|
||||
[InlineData(S7TsapDefaults.S7BasicClassHighByte, 0, 2, 0x0302)]
|
||||
// S7-1200 / S7-1500 onboard PN — rack=0 slot=0 → low byte 0x00.
|
||||
[InlineData(S7TsapDefaults.PgClassHighByte, 0, 0, 0x0100)]
|
||||
// S7-400 distributed — rack=1 slot=3 → low byte = (1<<5)|3 = 0x23.
|
||||
[InlineData(S7TsapDefaults.OpClassHighByte, 1, 3, 0x0223)]
|
||||
public void BuildRemoteTsap_packs_class_rack_and_slot_per_S7_spec(byte cls, int rack, int slot, ushort expected)
|
||||
{
|
||||
S7TsapDefaults.BuildRemoteTsap(cls, rack, slot).ShouldBe(expected);
|
||||
}
|
||||
|
||||
[Theory]
|
||||
[InlineData(-1, 0)]
|
||||
[InlineData(16, 0)]
|
||||
[InlineData(0, -1)]
|
||||
[InlineData(0, 32)]
|
||||
public void BuildRemoteTsap_throws_on_out_of_range_rack_or_slot(int rack, int slot)
|
||||
{
|
||||
Should.Throw<ArgumentOutOfRangeException>(() =>
|
||||
S7TsapDefaults.BuildRemoteTsap(S7TsapDefaults.PgClassHighByte, rack, slot));
|
||||
}
|
||||
|
||||
// ---- Driver construction (Other-mode missing-overrides validation) ----
|
||||
|
||||
[Fact]
|
||||
public async Task Other_mode_without_LocalTsap_or_RemoteTsap_throws_at_initialize()
|
||||
{
|
||||
// No LocalTsap / RemoteTsap → BuildPlc should refuse before opening the socket.
|
||||
var opts = new S7DriverOptions
|
||||
{
|
||||
Host = "192.0.2.1",
|
||||
Timeout = TimeSpan.FromMilliseconds(250),
|
||||
TsapMode = TsapMode.Other,
|
||||
};
|
||||
using var drv = new S7Driver(opts, "s7-other-missing");
|
||||
|
||||
var ex = await Should.ThrowAsync<InvalidOperationException>(async () =>
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken));
|
||||
ex.Message.ShouldContain("LocalTsap");
|
||||
ex.Message.ShouldContain("RemoteTsap");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Other_mode_with_only_LocalTsap_set_still_throws()
|
||||
{
|
||||
var opts = new S7DriverOptions
|
||||
{
|
||||
Host = "192.0.2.1",
|
||||
Timeout = TimeSpan.FromMilliseconds(250),
|
||||
TsapMode = TsapMode.Other,
|
||||
LocalTsap = 0x4D57,
|
||||
// RemoteTsap intentionally null
|
||||
};
|
||||
using var drv = new S7Driver(opts, "s7-other-half");
|
||||
|
||||
await Should.ThrowAsync<InvalidOperationException>(async () =>
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken));
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Other_mode_with_both_overrides_does_not_fail_at_BuildPlc_stage()
|
||||
{
|
||||
// With Other-mode + both overrides, BuildPlc must succeed; the connect itself fails
|
||||
// because 192.0.2.1 is unroutable (RFC 5737), so we expect a transport-shaped Exception
|
||||
// (NOT InvalidOperationException complaining about missing TSAPs).
|
||||
var opts = new S7DriverOptions
|
||||
{
|
||||
Host = "192.0.2.1",
|
||||
Timeout = TimeSpan.FromMilliseconds(250),
|
||||
TsapMode = TsapMode.Other,
|
||||
LocalTsap = 0x4D57,
|
||||
RemoteTsap = 0x4D58,
|
||||
};
|
||||
using var drv = new S7Driver(opts, "s7-other-ok");
|
||||
|
||||
var ex = await Should.ThrowAsync<Exception>(async () =>
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken));
|
||||
// Should not be the "missing LocalTsap/RemoteTsap" guard — that guard rejects on
|
||||
// Type, this should be a transport / timeout failure shape.
|
||||
(ex is InvalidOperationException io && io.Message.Contains("LocalTsap"))
|
||||
.ShouldBeFalse("Other-mode with both overrides set must pass the BuildPlc guard");
|
||||
}
|
||||
|
||||
// ---- DTO round-trip ----
|
||||
|
||||
[Fact]
|
||||
public void DTO_round_trip_with_TsapMode_Op_and_explicit_overrides()
|
||||
{
|
||||
// Mirrors what the central config DB hands to S7DriverFactoryExtensions.CreateInstance.
|
||||
var json = """
|
||||
{
|
||||
"Host": "192.168.1.30",
|
||||
"CpuType": "S71500",
|
||||
"Rack": 0,
|
||||
"Slot": 0,
|
||||
"TsapMode": "Op",
|
||||
"LocalTsap": 768,
|
||||
"RemoteTsap": 770,
|
||||
"Tags": []
|
||||
}
|
||||
""";
|
||||
var drv = (S7Driver)S7DriverFactoryExtensions.CreateInstance("s7-dto", json);
|
||||
drv.ShouldNotBeNull();
|
||||
drv.DriverInstanceId.ShouldBe("s7-dto");
|
||||
drv.Dispose();
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void DTO_unknown_TsapMode_is_rejected()
|
||||
{
|
||||
var json = """
|
||||
{
|
||||
"Host": "192.168.1.30",
|
||||
"TsapMode": "ProfiNet",
|
||||
"Tags": []
|
||||
}
|
||||
""";
|
||||
Should.Throw<InvalidOperationException>(() =>
|
||||
S7DriverFactoryExtensions.CreateInstance("s7-bad-mode", json));
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void DTO_omitting_TsapMode_falls_back_to_Auto()
|
||||
{
|
||||
// Critical for backwards-compat: pre-PR-S7-C2 configs must still load.
|
||||
var json = """
|
||||
{
|
||||
"Host": "192.168.1.30",
|
||||
"Tags": []
|
||||
}
|
||||
""";
|
||||
var drv = S7DriverFactoryExtensions.CreateInstance("s7-legacy", json);
|
||||
drv.ShouldNotBeNull();
|
||||
drv.Dispose();
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void DTO_round_trip_serialise_then_deserialise_preserves_TSAP_fields()
|
||||
{
|
||||
// Round-trip through the DTO type the factory uses, to catch property-name mismatches.
|
||||
var dto = new S7DriverFactoryExtensions.S7DriverConfigDto
|
||||
{
|
||||
Host = "10.0.0.5",
|
||||
TsapMode = "S7Basic",
|
||||
LocalTsap = 0x0300,
|
||||
RemoteTsap = 0x0302,
|
||||
};
|
||||
var json = JsonSerializer.Serialize(dto);
|
||||
var back = JsonSerializer.Deserialize<S7DriverFactoryExtensions.S7DriverConfigDto>(json)!;
|
||||
back.TsapMode.ShouldBe("S7Basic");
|
||||
back.LocalTsap.ShouldBe((ushort)0x0300);
|
||||
back.RemoteTsap.ShouldBe((ushort)0x0302);
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user