test(historian): wire test expects the Gateway's default aggregate set without TimeAverage/Total (lmxopcua#746)
v2-ci / unit-tests (push) Has been cancelled
v2-ci / unit-tests (push) Has been cancelled
The H2 merge (0b85c499) stopped advertising native Gateway TimeAverage/Total until historiangw#27; it updated the Host test (4e76eeb5) but not AdvertisedAggregateFunctionsWireTests, which failed 2/7 on master. Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
This commit is contained in:
+2
-2
@@ -20,11 +20,11 @@ namespace ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests;
|
|||||||
/// </summary>
|
/// </summary>
|
||||||
public sealed class AdvertisedAggregateFunctionsWireTests
|
public sealed class AdvertisedAggregateFunctionsWireTests
|
||||||
{
|
{
|
||||||
// #681: the ten per-sample aggregates (raw-evaluated) + TimeAverage / Total (AVEVA-native).
|
// #681: the ten per-sample aggregates (raw-evaluated). AVEVA-native TimeAverage / Total are no longer advertised by
|
||||||
|
// default (lmxopcua#746 refuses them until historiangw#27 is fixed and verified; EnableNativeTimeWeighted=true restores them).
|
||||||
private static readonly string[] GatewayNames =
|
private static readonly string[] GatewayNames =
|
||||||
[
|
[
|
||||||
"Average", "Count", "Delta", "End", "Maximum", "MaximumActualTime", "Minimum", "MinimumActualTime", "Range", "Start",
|
"Average", "Count", "Delta", "End", "Maximum", "MaximumActualTime", "Minimum", "MinimumActualTime", "Range", "Start",
|
||||||
"TimeAverage", "Total",
|
|
||||||
];
|
];
|
||||||
|
|
||||||
private static readonly string[] SqlNames =
|
private static readonly string[] SqlNames =
|
||||||
|
|||||||
Reference in New Issue
Block a user