feat(server): route OPC UA Part 9 shelve methods to ScriptedAlarmEngine (#24)
OneShotShelve / TimedShelve / Unshelve now reach the ScriptedAlarmEngine. Scripted-alarm condition nodes get a ShelvedStateMachine subtree created before alarm.Create so the stack wires each shelve method's dispatch handler; AlarmConditionState.OnShelve / OnTimedUnshelve route to the engine and mirror the result onto the OPC UA node via SetShelvingState. The three per-instance shelve method NodeIds are indexed so the Call gate resolves them to OpcUaOperation.AlarmShelve instead of falling through to generic Call. Engine dispatch is split into the node-free InvokeEngineShelve so the routing decision is unit-testable. Adds 9 unit tests; updates phase-7-status.md Gap 1 (only AddComment remains unwired) and the #24 entry in looseends.md. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -138,9 +138,9 @@ All three are verified closed in the 2026-04-23 exit-gate audit:
|
||||
|
||||
These are real open items, not issues with the plan reconciliation.
|
||||
|
||||
### Gap 1 — OPC UA method-call dispatch for scripted alarm Ack/Confirm/Shelve (Stream G / C.6)
|
||||
### Gap 1 — OPC UA method-call dispatch for scripted alarm AddComment (Stream G / C.6)
|
||||
|
||||
`DriverNodeManager.MethodCall` does not route OPC UA `Acknowledge` / `Confirm` / `OneShotShelve` / `TimedShelve` / `Unshelve` / `AddComment` method invocations to the `ScriptedAlarmEngine`. Operators can acknowledge scripted alarms through the Admin UI today; OPC UA HMI clients expecting to use Part 9 method nodes directly cannot. Explicit in `phase-7-e2e-smoke.md` §"Known limitations".
|
||||
`Acknowledge` / `Confirm` route to the `ScriptedAlarmEngine` via `DriverNodeManager.RouteScriptedAlarmMethodCalls` (task #24). `OneShotShelve` / `TimedShelve` / `Unshelve` route via the native `AlarmConditionState.OnShelve` / `OnTimedUnshelve` hooks wired in `MarkAsAlarmCondition` (task #24 follow-up); the per-instance shelve method NodeIds are indexed so the Call gate resolves them to `OpcUaOperation.AlarmShelve`. Only `AddComment` is still not wired to the OPC UA method path — the engine has `AddCommentAsync` but no Part 9 `AddComment` method node is dispatched to it.
|
||||
|
||||
### Gap 2 — Admin UI: no `/virtual-tags` tab or form (Stream F.2)
|
||||
|
||||
|
||||