fix(adminui): OpcUaClient editor reads the legacy PascalCase NodeId at the reader's precedence (#557 item 1)
`OpcUaClientTagDefinitionFactory.TryReadNodeId` still honours a legacy PascalCase `NodeId` when the v3 camelCase `nodeId` is wholly absent, but `OpcUaClientTagConfigModel` read only `nodeId` — so a legacy blob was SERVED by the driver yet opened with an empty reference field and could not be saved untouched. Authoring stricter than the reader, which #554 names as never legitimate: the editor was blocking config the runtime honours. Fixed with the #550 pattern (read both spellings, normalise on save), NOT by retiring the spelling from the reader — that would break every legacy blob the driver currently serves at the next deploy, a data-plane regression traded for an editor asymmetry. The precedence is PRESENCE-shadows, not first-non-blank. The reader's `TryGetProperty("nodeId", out n) || TryGetProperty("NodeId", out n)` short-circuits on the mere PRESENCE of the camelCase key and then checks string-and-non-blank ONCE, so a blank / non-string / JSON-null `nodeId` beside a valid legacy `NodeId` is a REJECTED blob, not a fallback. Copying MTConnect's `FirstNonBlank` walk here would have made authoring WEAKER than the reader — the same defect in mirror image. - `NodeIdKeys` drives both halves, so the read and the drop cannot drift. - `ToJson` writes `nodeId` and drops `NodeId`; the TagModal history-merge keys (`isHistorized` / `historianTagname`) are disjoint and untouched. - `Validate`'s required-reference fast path is now precedence-aware by construction, so it agrees with the #554 parse consult across the whole rejection surface. - The `TagConfigNonEnumParityTests` exemption for OpcUaClient is REMOVED — its anti-vacuity guard `Every_deliberately_stricter_entry_is_still_exactly_that` went red on the fix, which is this change's falsification control. The legacy shapes moved into the corpus, where both fleet theories now cover them. Tests: a nine-row precedence theory driving the authoring verdict against the READER's verdict per shape, on the original blob AND on the `ToJson()` output; no-retype (legacy loads showing its reference, saves canonical, same node id before and after); no-drift (output never carries `NodeId`). Each half was reverted in isolation to confirm it reddens tests of its own: read-only-revert => 6 red incl. the fleet parity theory; drop-only-revert => 4 red. Suites: AdminUI.Tests 1459/1459, ControlPlane.Tests 261/261, Driver.OpcUaClient.Tests 143/143, Driver.OpcUaClient.Browser.Tests 10/10.
This commit is contained in:
+9
@@ -32,6 +32,15 @@ public static class OpcUaClientTagDefinitionFactory
|
||||
/// Read the upstream node id string from an authored <c>TagConfig</c> blob's <c>nodeId</c> key
|
||||
/// (camelCase, per the AdminUI <c>OpcUaClientTagConfigModel</c>; a legacy PascalCase <c>NodeId</c>
|
||||
/// is also accepted). Never throws — a malformed blob yields <see langword="false"/>.
|
||||
/// <para>
|
||||
/// ⚠️ <b>The two spellings are PRESENCE-shadows, not first-non-blank.</b> The <c>||</c> below
|
||||
/// short-circuits on the mere presence of <c>nodeId</c> — whatever it holds — and the string /
|
||||
/// non-blank check then runs ONCE, on that one element. So the legacy <c>NodeId</c> is consulted
|
||||
/// only when <c>nodeId</c> is <i>wholly absent</i>: a blank or non-string <c>nodeId</c> beside a
|
||||
/// valid legacy <c>NodeId</c> is a rejected blob, not a fallback. The AdminUI model mirrors this
|
||||
/// walk exactly (Gitea #557 item 1) rather than the looser first-non-blank shape MTConnect's
|
||||
/// reader uses, which would let authoring accept a blob this reader refuses.
|
||||
/// </para>
|
||||
/// </summary>
|
||||
/// <param name="tagConfig">The authored equipment-tag TagConfig JSON.</param>
|
||||
/// <param name="nodeId">The upstream node id string when this returns <see langword="true"/>.</param>
|
||||
|
||||
Reference in New Issue