test(modbus, abcip): align failing integration tests with fixtures
Two real bugs uncovered by re-running with the new fixture defaults
pointing at the shared docker host. Both are test-side, not driver-side.
AbCip — Driver_reads_seeded_DInt_from_ab_server (4 parametrized rows):
Hardcoded 'ab://127.0.0.1:{port}/1,0' in the deviceUri instead of
the resolved fixture.Host. The new 10.100.0.35 default (and any
AB_SERVER_ENDPOINT override) silently couldn't reach this test —
the driver tried to connect to a non-existent localhost:44818 and
returned BadCommunicationError on all 4 profile rows. The sibling
Emulate tests already use the fixture's resolved endpoint; this
smoke test was missed in the original migration.
Fix: deviceUri = $"ab://{fixture.Host}:{fixture.Port}/1,0".
Modbus — Float32_With_CDAB_Roundtrips_Through_Wire:
Test wrote a Float32 to HR 100 (2 consecutive registers: 100+101).
standard.json's writable HR range declares [100,100] only — a
single-cell auto-incrementing register, not a 2-register pair. The
write to register 101 was rejected with Illegal Data Address
(BadOutOfRange).
Fix: moved the tag from HR 100 to HR 200 (in standard.json's
'[200, 209]' scratch range — 10 consecutive writable HRs). The
Float32+CDAB semantic the test exercises is unchanged.
Modbus — Block_Read_Coalescing_Reduces_PDU_Count_End_To_End:
Test read HR 300, 302, 304 — outside both the writable ranges and
the uint16 seed list. pymodbus rejects reads to unseeded HRs even
though 'hr size' is 2048. BadOutOfRange on every read.
Fix: moved the tags from 300/302/304 to 200/202/204 (within the
scratch range). The non-contiguous coalescing semantic (3 tags
inside a 5-register window with MaxReadGap=5) is preserved.
After this commit:
- Modbus.IntegrationTests: 6/38 pass / 32 skip / 0 fail
(was 4 pass / 32 skip / 2 fail; 32 skips are profile-gated
ExceptionInjectionTests — they need MODBUS_SIM_PROFILE=
exception_injection and a different container, intentional gating)
- AbCip.IntegrationTests: 10/12 pass / 2 skip / 0 fail
(was 6 pass / 2 skip / 4 fail; 2 skips are Emulate tests that
need the fixture for separate scenarios)
No driver code changed.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -54,7 +54,12 @@ public sealed class AddressingGrammarTests
|
||||
{
|
||||
if (_sim.SkipReason is not null) Assert.Skip(_sim.SkipReason);
|
||||
|
||||
var tag = new ModbusTagDefinition("Tank", ModbusRegion.HoldingRegisters, 100, ModbusDataType.Float32,
|
||||
// HR 200 lives in pymodbus's scratch range (`write: [200, 209]` per standard.json),
|
||||
// which gives us two consecutive writable HRs for the Float32 round-trip. The earlier
|
||||
// version used HR 100 — but standard.json declares HR 100 as a single-cell auto-
|
||||
// incrementing register (`write: [100, 100]`) so the second register of the Float32
|
||||
// write was rejected with Illegal Data Address.
|
||||
var tag = new ModbusTagDefinition("Tank", ModbusRegion.HoldingRegisters, 200, ModbusDataType.Float32,
|
||||
ByteOrder: ModbusByteOrder.WordSwap);
|
||||
var drv = await NewDriverAsync(tag);
|
||||
|
||||
@@ -87,9 +92,13 @@ public sealed class AddressingGrammarTests
|
||||
if (_sim.SkipReason is not null) Assert.Skip(_sim.SkipReason);
|
||||
|
||||
// Sanity check that the simulator accepts the larger PDU coalescing produces.
|
||||
var t1 = new ModbusTagDefinition("T1", ModbusRegion.HoldingRegisters, 300, ModbusDataType.Int16);
|
||||
var t2 = new ModbusTagDefinition("T2", ModbusRegion.HoldingRegisters, 302, ModbusDataType.Int16);
|
||||
var t3 = new ModbusTagDefinition("T3", ModbusRegion.HoldingRegisters, 304, ModbusDataType.Int16);
|
||||
// Using HR 200/202/204 in the scratch range (standard.json's `uint16: 200..209`),
|
||||
// not 300/302/304 — pymodbus rejects reads outside the seeded uint16 list with
|
||||
// Illegal Data Address (= BadOutOfRange). The coalescing semantic the test
|
||||
// exercises is identical with the scratch addresses.
|
||||
var t1 = new ModbusTagDefinition("T1", ModbusRegion.HoldingRegisters, 200, ModbusDataType.Int16);
|
||||
var t2 = new ModbusTagDefinition("T2", ModbusRegion.HoldingRegisters, 202, ModbusDataType.Int16);
|
||||
var t3 = new ModbusTagDefinition("T3", ModbusRegion.HoldingRegisters, 204, ModbusDataType.Int16);
|
||||
var opts = new ModbusDriverOptions
|
||||
{
|
||||
Host = _sim.Host, Port = _sim.Port, Tags = [t1, t2, t3], MaxReadGap = 5,
|
||||
|
||||