refactor(drivers): delete the dead discovered-node injection path (§8.2, #507)
#507 was filed as "injection inert in v3, re-migrate onto the raw subtree". Reading it, the retained code is not revivable: it resolves equipment from EquipmentNode.DriverInstanceId UNION EquipmentTags, and BOTH are structurally empty in v3 (AddressSpaceComposer always constructs EquipmentNode with a null DriverInstanceId; DeploymentArtifact hard-codes an empty EquipmentTags set). Removing the guard would have changed a log line and injected nothing. So it is deleted rather than fixed, and #507 closes as superseded by /raw browse-commit. Removed: HandleDiscoveredNodes, PartitionDiscoveredByDeviceHost, ShouldWarnPartition, PlansRoutingEqual, ApplyDiscoveredPlansForDriver, _discoveredByDriver, the redeploy re-inject tail, DiscoveredNodeMapper, DiscoveredInjection, AddressSpaceApplier.MaterialiseDiscoveredNodes, OpcUaPublishActor.MaterialiseDiscoveredNodes, and the Runtime-local copies of CapturingAddressSpaceBuilder/DiscoveredNode. The connect-time discovery loop goes too (StartDiscovery, RediscoverTick, HandleRediscoverAsync, DiscoveredNodesReady, TriggerRediscovery). With injection gone it had no consumer, and leaving it would either dead-letter or keep browsing real devices up to ~15x per connect to drop the result. ITagDiscovery itself stays — the /raw browse picker drives it through Commons/Browsing/DiscoveryDriverBrowser, which never went through the actor, so the picker is unaffected. deferment.md §4.4 called the 18 DiscoveryInjectionDormantV3 tests "Real — blocked on #507". They are not: they assert an equipment-rooted graft (EquipmentRootNodeId == "EQ-1") that v3 cannot produce, so they could never have unskipped as written. Deleted along with DiscoveredNodeMapperTests, the CapturingAddressSpaceBuilder tests, and the MaterialiseDiscoveredNodes tests in AddressSpaceApplierTests/OpcUaPublishActorTests. Runtime.Tests skipped: 31 -> 13. IHostConnectivityProbe is deliberately NOT resolved here. GetHostStatuses() has no production call site and nothing writes a DriverHostStatus row, but the table was re-created in the v3 initial migration, so deleting on inference would be wrong. Split to Gitea #521 with both options costed. CLAUDE.md, docs/drivers/{Galaxy,TwinCAT,MTConnect}.md updated — they described the seam as dead. Build clean; Runtime.Tests 476 passed / 13 skipped; OpcUaServer.Tests 362 passed / 4 skipped.
This commit is contained in:
@@ -85,15 +85,6 @@ public sealed class OpcUaPublishActor : ReceiveActor, IWithTimers
|
||||
public sealed record RebuildAddressSpace(
|
||||
CorrelationId Correlation, DeploymentId? DeploymentId = null, byte[]? Artifact = null);
|
||||
|
||||
/// <summary>Inject driver-discovered nodes (FixedTree) under an equipment at runtime (post-connect).</summary>
|
||||
/// <param name="EquipmentRootNodeId">The OPC UA NodeId of the equipment root folder to inject the
|
||||
/// discovered nodes under (e.g. "EQ-3686c0272279"); also the node the NodeAdded model-change is
|
||||
/// announced under.</param>
|
||||
public sealed record MaterialiseDiscoveredNodes(
|
||||
string EquipmentRootNodeId,
|
||||
IReadOnlyList<DiscoveredFolder> Folders,
|
||||
IReadOnlyList<DiscoveredVariable> Variables);
|
||||
|
||||
public sealed record ServiceLevelChanged(byte ServiceLevel);
|
||||
|
||||
private readonly IOpcUaAddressSpaceSink _sink;
|
||||
@@ -284,7 +275,6 @@ public sealed class OpcUaPublishActor : ReceiveActor, IWithTimers
|
||||
Receive<AlarmStateUpdate>(HandleAlarmUpdate);
|
||||
Receive<AlarmQualityUpdate>(HandleAlarmQualityUpdate);
|
||||
Receive<RebuildAddressSpace>(HandleRebuild);
|
||||
Receive<MaterialiseDiscoveredNodes>(HandleMaterialiseDiscovered);
|
||||
Receive<ServiceLevelChanged>(HandleServiceLevelChanged);
|
||||
Receive<RedundancyStateChanged>(HandleRedundancyStateChanged);
|
||||
Receive<DbHealthProbeActor.DbHealthStatus>(HandleDbHealthStatus);
|
||||
@@ -539,28 +529,6 @@ public sealed class OpcUaPublishActor : ReceiveActor, IWithTimers
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Forwards driver-discovered (FixedTree) nodes to the applier so they are injected under
|
||||
/// the equipment at runtime. No-op (logged) when no applier is wired (dev/Mac/legacy seam), matching the
|
||||
/// optional-applier tolerance of <see cref="HandleRebuild"/>.</summary>
|
||||
private void HandleMaterialiseDiscovered(MaterialiseDiscoveredNodes msg)
|
||||
{
|
||||
if (_applier is null)
|
||||
{
|
||||
_log.Debug("OpcUaPublish: no applier wired — discarding MaterialiseDiscoveredNodes for {Equipment}", msg.EquipmentRootNodeId);
|
||||
return;
|
||||
}
|
||||
var failedNodes = _applier.MaterialiseDiscoveredNodes(msg.EquipmentRootNodeId, msg.Folders, msg.Variables);
|
||||
if (failedNodes > 0)
|
||||
{
|
||||
// archreview 01/S-1: a swallowed discovered-node injection failure surfaces at Error + the
|
||||
// dedicated meter instead of vanishing into per-node Warnings.
|
||||
OtOpcUaTelemetry.OpcUaApplyFailed.Add(1, new KeyValuePair<string, object?>("kind", "nodes"));
|
||||
_log.Error(
|
||||
"OpcUaPublish: discovered-node injection DEGRADED for {Equipment} (failedNodes={FailedNodes}) — some discovered nodes may be missing",
|
||||
msg.EquipmentRootNodeId, failedNodes);
|
||||
}
|
||||
}
|
||||
|
||||
private void HandleServiceLevelChanged(ServiceLevelChanged msg)
|
||||
{
|
||||
// Always publish the FIRST computed level, even if it equals the byte-default 0. Otherwise a
|
||||
|
||||