fix(redundancy): a failed OPC UA endpoint drops ServiceLevel to 0 and steps the Primary down (lmxopcua#762)
v2-ci / unit-tests (push) Has been cancelled
v2-ci / unit-tests (push) Has been cancelled
IOpcUaEndpointState (review-remediation lane C3) recorded whether the SDK started, but only the health check read it: a fused node whose endpoint failed (port 4840 taken, ...) still advertised 250/240 and stayed driver Primary, so the Primary-gated data plane ran on a node no client could reach while the reachable peer refused writes as Secondary. - Move IOpcUaEndpointState/OpcUaEndpointState/OpcUaEndpointStatus from Host to Commons.OpcUa so the Runtime can consume it. - ServiceLevelCalculator: new NodeHealthInputs.EndpointListening (default true). false -> 0, ahead of every other input including the +10 Primary bonus. - OpcUaPublishActor: takes the endpoint state, feeds EndpointListening (Failed only; NotStarted / Stopped are boot/shutdown windows) on the DB-backed and DB-less paths, and the legacy role-only seam returns 0 for a failed endpoint too. - New OpcUaEndpointStepDownActor (one per driver node): a Primary (ClusterActiveNode.SelfIsActive, the election's own primitive) with a Failed endpoint gracefully Leaves its mesh - the manual failover mechanism - so the peer becomes the oldest Up driver member, hosts the singletons and is Primary. The election itself is not bent. Guarded on a peer having recently reported its own endpoint listening (EndpointReport on the new opcua-endpoint-state DPS topic), so a pair with both endpoints failed does not bounce the role and restart nodes forever, and a lone node never shuts itself down. - Runtime now references ZB.MOM.WW.Health.Akka (ClusterActiveNode). - Docs: Redundancy.md tier table + new "Endpoint start failure: Primary step-down" section; cluster-topology rule; HealthEndpoints / OpcUaEndpointHealthCheck comments (F-C1 landed). Tests: ServiceLevelCalculatorTests (+5), OpcUaPublishActorEndpointStateTests (7: DB-less, DB-backed, legacy seam, NotStarted/Stopped do not demote, a later failure demotes on the next tick), OpcUaEndpointStepDownActorTests (3, real two-node mesh: holds while the peer is not listening then leaves and the peer becomes Primary; failed Secondary and healthy Primary never leave). Each was mutation-checked: removing the calculator/legacy guard, the Leave, the peer-listening guard or the Primary guard fails the corresponding tests.
This commit is contained in:
@@ -44,6 +44,7 @@ public static class ServiceCollectionExtensions
|
||||
public const string DependencyMuxActorName = "dependency-mux";
|
||||
public const string OpcUaPublishActorName = "opcua-publish";
|
||||
public const string PeerProbeSupervisorName = "peer-probe-supervisor";
|
||||
public const string OpcUaEndpointStepDownActorName = "opcua-endpoint-step-down";
|
||||
public const string ContinuousHistorizationRecorderActorName = "continuous-historization-recorder";
|
||||
|
||||
/// <summary>
|
||||
@@ -555,6 +556,10 @@ public static class ServiceCollectionExtensions
|
||||
// a node with no driver role never registers it and test harnesses build this graph without it;
|
||||
// the actor treats null as "nothing consumes authorization inputs" and skips the decode.
|
||||
var dataPlaneAuthority = resolver.GetService<IDataPlaneAuthoritySink>();
|
||||
// lmxopcua#762: the "did the OPC UA SDK start?" fact the Host's OtOpcUaServerHostedService maintains.
|
||||
// Optional: a harness that builds this graph without the hosted service registers none, and both
|
||||
// consumers then behave as if the endpoint were listening (the pre-#762 behaviour).
|
||||
var endpointState = resolver.GetService<IOpcUaEndpointState>();
|
||||
var publishActor = system.ActorOf(
|
||||
OpcUaPublishActor.Props(
|
||||
sink: addressSpaceSink,
|
||||
@@ -564,10 +569,19 @@ public static class ServiceCollectionExtensions
|
||||
applier: applier,
|
||||
dbHealthProbe: dbHealth,
|
||||
dbLess: dbFactory is null,
|
||||
dataPlaneAuthority: dataPlaneAuthority),
|
||||
dataPlaneAuthority: dataPlaneAuthority,
|
||||
endpointState: endpointState),
|
||||
OpcUaPublishActorName);
|
||||
registry.Register<OpcUaPublishActorKey>(publishActor);
|
||||
|
||||
// lmxopcua#762: a driver Primary whose OPC UA endpoint failed to start leaves its mesh once a peer
|
||||
// reports a listening endpoint, so the peer becomes Primary. Every driver node runs one — it is also
|
||||
// how this node tells its peer whether IT can take over.
|
||||
if (endpointState is not null)
|
||||
{
|
||||
system.ActorOf(OpcUaEndpointStepDownActor.Props(endpointState), OpcUaEndpointStepDownActorName);
|
||||
}
|
||||
|
||||
// Per-node peer-probe supervisor — keeps one OPC UA TCP probe per OTHER non-Detached
|
||||
// driver node, so every node is continuously probed by all its peers. OpcUaPublishActor
|
||||
// consumes the resulting probe verdicts to learn this node's own reachability.
|
||||
|
||||
Reference in New Issue