Task #253 follow-up — bidirectional + subscribe-sees-change e2e stages
The original three-stage design (probe / driver-loopback / forward- bridge) only proved driver-write → server-read. It missed: - OPC UA write → server → driver → PLC (the reverse direction) - server-side data-change notifications actually firing (a stale subscription can still let a read-after-the-fact return the new value and look fine) Extend _common.ps1 with two helpers: - Test-OpcUaWriteBridge: otopcua-cli write the NodeId -> wait 3s -> driver CLI read the PLC side, assert equality. - Test-SubscribeSeesChange: Start-Process otopcua-cli subscribe in the background with --duration N, settle 2s, driver-side write, wait for the subscription window to close, assert captured stdout contains the new value. Wire both into test-modbus / test-abcip / test-ablegacy / test-s7 / test-focas / test-twincat after the existing forward-bridge stage. Update README to describe the five-stage design + note that the published NodeId must be writable for stages 4 + 5. Also prepend UTF-8 BOM to every script in scripts/e2e so Windows PowerShell 5.1 parsers agree on em-dash byte sequences the way PowerShell 7 already does. The scripts still #Requires -Version 7.0 — the BOM is purely defensive for IDE / CI step parsers. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -1,13 +1,15 @@
|
||||
#Requires -Version 7.0
|
||||
#Requires -Version 7.0
|
||||
<#
|
||||
.SYNOPSIS
|
||||
End-to-end CLI test for the Modbus-TCP driver bridged through the OtOpcUa server.
|
||||
|
||||
.DESCRIPTION
|
||||
Three assertions:
|
||||
Five assertions:
|
||||
1. `otopcua-modbus-cli probe` hits the simulator
|
||||
2. Driver-loopback write + read-back via modbus-cli
|
||||
3. Bridge: modbus-cli writes HR[100], OPC UA client reads the bridged NodeId
|
||||
3. Forward bridge: modbus-cli writes HR[100], OPC UA client reads the bridged NodeId
|
||||
4. Reverse bridge: OPC UA client writes the NodeId, modbus-cli reads HR[100]
|
||||
5. Subscribe-sees-change: OPC UA subscription observes a modbus-cli write
|
||||
|
||||
Requires a running Modbus simulator on localhost:5502 (the pymodbus fixture
|
||||
default per docs/drivers/Modbus-Test-Fixture.md) and a running OtOpcUa server
|
||||
@@ -70,5 +72,23 @@ $results += Test-ServerBridge `
|
||||
-OpcUaNodeId $BridgeNodeId `
|
||||
-ExpectedValue "$bridgeValue"
|
||||
|
||||
$reverseValue = Get-Random -Minimum 20000 -Maximum 29999
|
||||
$results += Test-OpcUaWriteBridge `
|
||||
-OpcUaCli $opcUaCli `
|
||||
-OpcUaUrl $OpcUaUrl `
|
||||
-OpcUaNodeId $BridgeNodeId `
|
||||
-DriverCli $modbusCli `
|
||||
-DriverReadArgs (@("read") + $commonModbus + @("-r", "HoldingRegisters", "-a", "100", "-t", "UInt16")) `
|
||||
-ExpectedValue "$reverseValue"
|
||||
|
||||
$subValue = Get-Random -Minimum 30000 -Maximum 39999
|
||||
$results += Test-SubscribeSeesChange `
|
||||
-OpcUaCli $opcUaCli `
|
||||
-OpcUaUrl $OpcUaUrl `
|
||||
-OpcUaNodeId $BridgeNodeId `
|
||||
-DriverCli $modbusCli `
|
||||
-DriverWriteArgs (@("write") + $commonModbus + @("-r", "HoldingRegisters", "-a", "100", "-t", "UInt16", "-v", $subValue)) `
|
||||
-ExpectedValue "$subValue"
|
||||
|
||||
Write-Summary -Title "Modbus e2e" -Results $results
|
||||
if ($results | Where-Object { -not $_.Passed }) { exit 1 }
|
||||
|
||||