Phase 2 Stream D Option B — archive v1 surface + new Driver.Galaxy.E2E parity suite. Non-destructive intermediate state: the v1 OtOpcUa.Host + Historian.Aveva + Tests + IntegrationTests projects all still build (494 v1 unit + 6 v1 integration tests still pass when run explicitly), but solution-level dotnet test ZB.MOM.WW.OtOpcUa.slnx now skips them via IsTestProject=false on the test projects + archive-status PropertyGroup comments on the src projects. The destructive deletion is reserved for Phase 2 PR 3 with explicit operator review per CLAUDE.md "only use destructive operations when truly the best approach". tests/ZB.MOM.WW.OtOpcUa.Tests/ renamed via git mv to tests/ZB.MOM.WW.OtOpcUa.Tests.v1Archive/; csproj <AssemblyName> kept as the original ZB.MOM.WW.OtOpcUa.Tests so v1 OtOpcUa.Host's [InternalsVisibleTo("ZB.MOM.WW.OtOpcUa.Tests")] still matches and the project rebuilds clean. tests/ZB.MOM.WW.OtOpcUa.IntegrationTests gets <IsTestProject>false</IsTestProject>. src/ZB.MOM.WW.OtOpcUa.Host + src/ZB.MOM.WW.OtOpcUa.Historian.Aveva get PropertyGroup archive-status comments documenting they're functionally superseded but kept in-build because cascading dependencies (Historian.Aveva → Host; IntegrationTests → Host) make a single-PR deletion high blast-radius. New tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.E2E/ project (.NET 10) with ParityFixture that spawns OtOpcUa.Driver.Galaxy.Host.exe (net48 x86) as a Process.Start subprocess with OTOPCUA_GALAXY_BACKEND=db env vars, awaits 2s for the PipeServer to bind, then exposes a connected GalaxyProxyDriver; skips on non-Windows / Administrator shells (PipeAcl denies admins per decision #76) / ZB unreachable / Host EXE not built — each skip carries a SkipReason string the test method reads via Assert.Skip(SkipReason). RecordingAddressSpaceBuilder captures every Folder/Variable/AddProperty registration so parity tests can assert on the same shape v1 LmxNodeManager produced. HierarchyParityTests (3) — Discover returns gobjects with attributes; attribute full references match the tag.attribute Galaxy reference grammar; HistoryExtension flag flows through correctly. StabilityFindingsRegressionTests (4) — one test per 2026-04-13 stability finding from commits c76ab8f and 7310925: phantom probe subscription doesn't corrupt unrelated host status; HostStatusChangedEventArgs structurally carries a specific HostName + OldState + NewState (event signature mathematically prevents the v1 cross-host quality-clear bug); all GalaxyProxyDriver capability methods return Task or Task<T> (sync-over-async would deadlock OPC UA stack thread); AcknowledgeAsync completes before returning (no fire-and-forget background work that could race shutdown). Solution test count: 470 pass / 7 skip (E2E on admin shell) / 1 pre-existing Phase 0 baseline. Run archived suites explicitly: dotnet test tests/ZB.MOM.WW.OtOpcUa.Tests.v1Archive (494 pass) + dotnet test tests/ZB.MOM.WW.OtOpcUa.IntegrationTests (6 pass). docs/v2/V1_ARCHIVE_STATUS.md inventories every archived surface with run-it-explicitly instructions + a 10-step deletion plan for PR 3 + rollback procedure (git revert restores all four projects). docs/v2/implementation/exit-gate-phase-2-final.md supersedes the two partial-exit docs with the per-stream status table (A/B/C/D/E all addressed, D split across PR 2/3 per safety protocol), the test count breakdown, fresh adversarial review of PR 2 deltas (4 new findings: medium IsTestProject=false safety net loss, medium structural-vs-behavioral stability tests, low backend=db default, low Process.Start env inheritance), the 8 carried-forward findings from exit-gate-phase-2.md, the recommended PR order (1 → 2 → 3 → 4). docs/v2/implementation/pr-2-body.md is the Gitea web-UI paste-in for opening PR 2 once pushed.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -0,0 +1,58 @@
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Threading;
|
||||
using System.Threading.Tasks;
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Host.Domain;
|
||||
using ZB.MOM.WW.OtOpcUa.Host.GalaxyRepository;
|
||||
using ZB.MOM.WW.OtOpcUa.Tests.Helpers;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Tests.Wiring
|
||||
{
|
||||
/// <summary>
|
||||
/// Verifies: Galaxy change detection → OnGalaxyChanged → address space rebuild
|
||||
/// </summary>
|
||||
public class ChangeDetectionToRebuildWiringTest
|
||||
{
|
||||
/// <summary>
|
||||
/// Confirms that a changed deploy timestamp causes the change-detection pipeline to raise another rebuild signal.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public async Task ChangedTimestamp_TriggersRebuild()
|
||||
{
|
||||
var repo = new FakeGalaxyRepository
|
||||
{
|
||||
LastDeployTime = new DateTime(2024, 1, 1),
|
||||
Hierarchy = new List<GalaxyObjectInfo>
|
||||
{
|
||||
new() { GobjectId = 1, TagName = "Obj1", BrowseName = "Obj1", ParentGobjectId = 0, IsArea = false }
|
||||
},
|
||||
Attributes = new List<GalaxyAttributeInfo>
|
||||
{
|
||||
new()
|
||||
{
|
||||
GobjectId = 1, TagName = "Obj1", AttributeName = "Attr1", FullTagReference = "Obj1.Attr1",
|
||||
MxDataType = 5, IsArray = false
|
||||
}
|
||||
}
|
||||
};
|
||||
|
||||
var rebuildCount = 0;
|
||||
var service = new ChangeDetectionService(repo, 1);
|
||||
service.OnGalaxyChanged += () => Interlocked.Increment(ref rebuildCount);
|
||||
|
||||
service.Start();
|
||||
await Task.Delay(500); // First poll triggers
|
||||
rebuildCount.ShouldBeGreaterThanOrEqualTo(1);
|
||||
|
||||
// Change deploy time → should trigger rebuild
|
||||
repo.LastDeployTime = new DateTime(2024, 2, 1);
|
||||
await Task.Delay(1500);
|
||||
service.Stop();
|
||||
|
||||
rebuildCount.ShouldBeGreaterThanOrEqualTo(2);
|
||||
service.Dispose();
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,54 @@
|
||||
using System.Threading.Tasks;
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Host.Domain;
|
||||
using ZB.MOM.WW.OtOpcUa.Tests.Helpers;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Tests.Wiring
|
||||
{
|
||||
/// <summary>
|
||||
/// Verifies: FakeMxProxy OnDataChange → MxAccessClient → OnTagValueChanged → node manager delivery
|
||||
/// </summary>
|
||||
public class MxAccessToNodeManagerWiringTest
|
||||
{
|
||||
/// <summary>
|
||||
/// Confirms that a simulated data change reaches the global tag-value-changed event.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public async Task DataChange_ReachesGlobalHandler()
|
||||
{
|
||||
var mxClient = new FakeMxAccessClient();
|
||||
string? receivedAddress = null;
|
||||
Vtq? receivedVtq = null;
|
||||
|
||||
mxClient.OnTagValueChanged += (addr, vtq) =>
|
||||
{
|
||||
receivedAddress = addr;
|
||||
receivedVtq = vtq;
|
||||
};
|
||||
|
||||
mxClient.SimulateDataChange("TestTag.Attr", Vtq.Good(42));
|
||||
|
||||
receivedAddress.ShouldBe("TestTag.Attr");
|
||||
receivedVtq.ShouldNotBeNull();
|
||||
receivedVtq.Value.Value.ShouldBe(42);
|
||||
receivedVtq.Value.Quality.ShouldBe(Quality.Good);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Confirms that a simulated data change reaches the stored per-tag subscription callback.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public async Task DataChange_ReachesSubscriptionCallback()
|
||||
{
|
||||
var mxClient = new FakeMxAccessClient();
|
||||
Vtq? received = null;
|
||||
|
||||
await mxClient.SubscribeAsync("TestTag.Attr", (addr, vtq) => received = vtq);
|
||||
mxClient.SimulateDataChange("TestTag.Attr", Vtq.Good(99));
|
||||
|
||||
received.ShouldNotBeNull();
|
||||
received.Value.Value.ShouldBe(99);
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,59 @@
|
||||
using System.Collections.Generic;
|
||||
using System.Threading.Tasks;
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Host.Domain;
|
||||
using ZB.MOM.WW.OtOpcUa.Host.OpcUa;
|
||||
using ZB.MOM.WW.OtOpcUa.Tests.Helpers;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Tests.Wiring
|
||||
{
|
||||
/// <summary>
|
||||
/// Verifies: OPC UA Read → NodeManager → IMxAccessClient.ReadAsync with correct full_tag_reference
|
||||
/// </summary>
|
||||
public class OpcUaReadToMxAccessWiringTest
|
||||
{
|
||||
/// <summary>
|
||||
/// Confirms that the resolved OPC UA read path uses the expected full Galaxy tag reference.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public async Task Read_ResolvesCorrectTagReference()
|
||||
{
|
||||
var mxClient = new FakeMxAccessClient();
|
||||
mxClient.TagValues["DelmiaReceiver_001.DownloadPath"] = Vtq.Good("/some/path");
|
||||
|
||||
var hierarchy = new List<GalaxyObjectInfo>
|
||||
{
|
||||
new()
|
||||
{
|
||||
GobjectId = 1, TagName = "TestMachine_001", BrowseName = "TestMachine_001", ParentGobjectId = 0,
|
||||
IsArea = false
|
||||
},
|
||||
new()
|
||||
{
|
||||
GobjectId = 2, TagName = "DelmiaReceiver_001", ContainedName = "DelmiaReceiver",
|
||||
BrowseName = "DelmiaReceiver", ParentGobjectId = 1, IsArea = false
|
||||
}
|
||||
};
|
||||
var attributes = new List<GalaxyAttributeInfo>
|
||||
{
|
||||
new()
|
||||
{
|
||||
GobjectId = 2, TagName = "DelmiaReceiver_001", AttributeName = "DownloadPath",
|
||||
FullTagReference = "DelmiaReceiver_001.DownloadPath", MxDataType = 5, IsArray = false
|
||||
}
|
||||
};
|
||||
|
||||
var model = AddressSpaceBuilder.Build(hierarchy, attributes);
|
||||
|
||||
// The model should contain the correct tag reference
|
||||
model.NodeIdToTagReference.ContainsKey("DelmiaReceiver_001.DownloadPath").ShouldBe(true);
|
||||
model.NodeIdToTagReference["DelmiaReceiver_001.DownloadPath"].ShouldBe("DelmiaReceiver_001.DownloadPath");
|
||||
|
||||
// The MxAccessClient should be able to read using the tag reference
|
||||
var vtq = await mxClient.ReadAsync("DelmiaReceiver_001.DownloadPath");
|
||||
vtq.Value.ShouldBe("/some/path");
|
||||
vtq.Quality.ShouldBe(Quality.Good);
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,78 @@
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Net;
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Host;
|
||||
using ZB.MOM.WW.OtOpcUa.Host.Configuration;
|
||||
using ZB.MOM.WW.OtOpcUa.Host.Domain;
|
||||
using ZB.MOM.WW.OtOpcUa.Tests.Helpers;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Tests.Wiring
|
||||
{
|
||||
/// <summary>
|
||||
/// Regression for stability review 2026-04-13 Finding 2. Confirms that when the dashboard
|
||||
/// port is already bound, the service continues to start (degraded mode) and the
|
||||
/// <see cref="OpcUaService.DashboardStartFailed"/> flag is raised.
|
||||
/// </summary>
|
||||
public class OpcUaServiceDashboardFailureTests
|
||||
{
|
||||
[Fact]
|
||||
public void Start_DashboardPortInUse_ContinuesInDegradedMode()
|
||||
{
|
||||
var dashboardPort = new Random().Next(19500, 19999);
|
||||
using var blocker = new HttpListener();
|
||||
blocker.Prefixes.Add($"http://localhost:{dashboardPort}/");
|
||||
blocker.Start();
|
||||
|
||||
var config = new AppConfiguration
|
||||
{
|
||||
OpcUa = new OpcUaConfiguration
|
||||
{
|
||||
Port = 14842,
|
||||
GalaxyName = "TestGalaxy",
|
||||
EndpointPath = "/LmxOpcUa"
|
||||
},
|
||||
MxAccess = new MxAccessConfiguration { ClientName = "Test" },
|
||||
GalaxyRepository = new GalaxyRepositoryConfiguration(),
|
||||
Dashboard = new DashboardConfiguration { Enabled = true, Port = dashboardPort }
|
||||
};
|
||||
|
||||
var proxy = new FakeMxProxy();
|
||||
var repo = new FakeGalaxyRepository
|
||||
{
|
||||
Hierarchy = new List<GalaxyObjectInfo>
|
||||
{
|
||||
new()
|
||||
{
|
||||
GobjectId = 1, TagName = "TestObj", BrowseName = "TestObj",
|
||||
ParentGobjectId = 0, IsArea = false
|
||||
}
|
||||
},
|
||||
Attributes = new List<GalaxyAttributeInfo>
|
||||
{
|
||||
new()
|
||||
{
|
||||
GobjectId = 1, TagName = "TestObj", AttributeName = "TestAttr",
|
||||
FullTagReference = "TestObj.TestAttr", MxDataType = 5, IsArray = false
|
||||
}
|
||||
}
|
||||
};
|
||||
|
||||
var service = new OpcUaService(config, proxy, repo);
|
||||
service.Start();
|
||||
|
||||
try
|
||||
{
|
||||
// Service continues despite dashboard bind failure — degraded mode policy.
|
||||
service.ServerHost.ShouldNotBeNull();
|
||||
service.DashboardStartFailed.ShouldBeTrue();
|
||||
service.StatusWeb.ShouldBeNull();
|
||||
}
|
||||
finally
|
||||
{
|
||||
service.Stop();
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,52 @@
|
||||
using System.Collections.Generic;
|
||||
using System.Threading.Tasks;
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Host.Domain;
|
||||
using ZB.MOM.WW.OtOpcUa.Host.OpcUa;
|
||||
using ZB.MOM.WW.OtOpcUa.Tests.Helpers;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Tests.Wiring
|
||||
{
|
||||
/// <summary>
|
||||
/// Verifies: OPC UA Write → NodeManager → IMxAccessClient.WriteAsync with correct tag+value
|
||||
/// </summary>
|
||||
public class OpcUaWriteToMxAccessWiringTest
|
||||
{
|
||||
/// <summary>
|
||||
/// Confirms that the resolved OPC UA write path targets the expected Galaxy tag reference and payload.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public async Task Write_SendsCorrectTagAndValue()
|
||||
{
|
||||
var mxClient = new FakeMxAccessClient();
|
||||
|
||||
var hierarchy = new List<GalaxyObjectInfo>
|
||||
{
|
||||
new()
|
||||
{
|
||||
GobjectId = 1, TagName = "TestMachine_001", BrowseName = "TestMachine_001", ParentGobjectId = 0,
|
||||
IsArea = false
|
||||
}
|
||||
};
|
||||
var attributes = new List<GalaxyAttributeInfo>
|
||||
{
|
||||
new()
|
||||
{
|
||||
GobjectId = 1, TagName = "TestMachine_001", AttributeName = "MachineCode",
|
||||
FullTagReference = "TestMachine_001.MachineCode", MxDataType = 5, IsArray = false
|
||||
}
|
||||
};
|
||||
|
||||
var model = AddressSpaceBuilder.Build(hierarchy, attributes);
|
||||
var tagRef = model.NodeIdToTagReference["TestMachine_001.MachineCode"];
|
||||
|
||||
// Write through MxAccessClient
|
||||
var result = await mxClient.WriteAsync(tagRef, "NEW_CODE");
|
||||
|
||||
result.ShouldBe(true);
|
||||
mxClient.WrittenValues.ShouldContain(w =>
|
||||
w.Tag == "TestMachine_001.MachineCode" && (string)w.Value == "NEW_CODE");
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,149 @@
|
||||
using System.Collections.Generic;
|
||||
using System.Threading.Tasks;
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Host;
|
||||
using ZB.MOM.WW.OtOpcUa.Host.Configuration;
|
||||
using ZB.MOM.WW.OtOpcUa.Host.Domain;
|
||||
using ZB.MOM.WW.OtOpcUa.Tests.Helpers;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Tests.Wiring
|
||||
{
|
||||
/// <summary>
|
||||
/// Verifies: OpcUaService Start() creates and wires all components with fakes.
|
||||
/// </summary>
|
||||
public class ServiceStartupSequenceTest
|
||||
{
|
||||
/// <summary>
|
||||
/// Confirms that startup with fake dependencies creates the expected bridge components and state.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void Start_WithFakes_AllComponentsCreated()
|
||||
{
|
||||
var config = new AppConfiguration
|
||||
{
|
||||
OpcUa = new OpcUaConfiguration
|
||||
{
|
||||
Port = 14840,
|
||||
GalaxyName = "TestGalaxy",
|
||||
EndpointPath = "/LmxOpcUa"
|
||||
},
|
||||
MxAccess = new MxAccessConfiguration { ClientName = "Test" },
|
||||
GalaxyRepository = new GalaxyRepositoryConfiguration(),
|
||||
Dashboard = new DashboardConfiguration { Enabled = false } // Don't start HTTP listener in tests
|
||||
};
|
||||
|
||||
var proxy = new FakeMxProxy();
|
||||
var repo = new FakeGalaxyRepository
|
||||
{
|
||||
Hierarchy = new List<GalaxyObjectInfo>
|
||||
{
|
||||
new()
|
||||
{
|
||||
GobjectId = 1, TagName = "TestObj", BrowseName = "TestObj", ParentGobjectId = 0, IsArea = false
|
||||
}
|
||||
},
|
||||
Attributes = new List<GalaxyAttributeInfo>
|
||||
{
|
||||
new()
|
||||
{
|
||||
GobjectId = 1, TagName = "TestObj", AttributeName = "TestAttr",
|
||||
FullTagReference = "TestObj.TestAttr", MxDataType = 5, IsArray = false
|
||||
}
|
||||
}
|
||||
};
|
||||
|
||||
var service = new OpcUaService(config, proxy, repo);
|
||||
service.Start();
|
||||
|
||||
try
|
||||
{
|
||||
// Verify all components were created
|
||||
service.MxClient.ShouldNotBeNull();
|
||||
service.MxClient!.State.ShouldBe(ConnectionState.Connected);
|
||||
service.Metrics.ShouldNotBeNull();
|
||||
service.ServerHost.ShouldNotBeNull();
|
||||
service.ChangeDetectionInstance.ShouldNotBeNull();
|
||||
service.GalaxyStatsInstance.ShouldNotBeNull();
|
||||
service.GalaxyStatsInstance!.GalaxyName.ShouldBe("TestGalaxy");
|
||||
service.GalaxyStatsInstance.DbConnected.ShouldBe(true);
|
||||
service.StatusReportInstance.ShouldNotBeNull();
|
||||
|
||||
// Dashboard disabled → no web server
|
||||
service.StatusWeb.ShouldBeNull();
|
||||
|
||||
// MxProxy should have been registered
|
||||
proxy.IsRegistered.ShouldBe(true);
|
||||
}
|
||||
finally
|
||||
{
|
||||
service.Stop();
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Confirms that when MXAccess is initially unavailable, the background monitor reconnects it later.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public async Task Start_WhenMxAccessIsInitiallyDown_MonitorReconnectsInBackground()
|
||||
{
|
||||
var config = new AppConfiguration
|
||||
{
|
||||
OpcUa = new OpcUaConfiguration
|
||||
{
|
||||
Port = 14841,
|
||||
GalaxyName = "TestGalaxy",
|
||||
EndpointPath = "/LmxOpcUa"
|
||||
},
|
||||
MxAccess = new MxAccessConfiguration
|
||||
{
|
||||
ClientName = "Test",
|
||||
MonitorIntervalSeconds = 1,
|
||||
AutoReconnect = true
|
||||
},
|
||||
GalaxyRepository = new GalaxyRepositoryConfiguration(),
|
||||
Dashboard = new DashboardConfiguration { Enabled = false }
|
||||
};
|
||||
|
||||
var proxy = new FakeMxProxy { ShouldFailRegister = true };
|
||||
var repo = new FakeGalaxyRepository
|
||||
{
|
||||
Hierarchy = new List<GalaxyObjectInfo>
|
||||
{
|
||||
new()
|
||||
{
|
||||
GobjectId = 1, TagName = "TestObj", BrowseName = "TestObj", ParentGobjectId = 0, IsArea = false
|
||||
}
|
||||
},
|
||||
Attributes = new List<GalaxyAttributeInfo>
|
||||
{
|
||||
new()
|
||||
{
|
||||
GobjectId = 1, TagName = "TestObj", AttributeName = "TestAttr",
|
||||
FullTagReference = "TestObj.TestAttr", MxDataType = 5, IsArray = false
|
||||
}
|
||||
}
|
||||
};
|
||||
|
||||
var service = new OpcUaService(config, proxy, repo);
|
||||
service.Start();
|
||||
|
||||
try
|
||||
{
|
||||
service.ServerHost.ShouldNotBeNull();
|
||||
service.MxClient.ShouldNotBeNull();
|
||||
service.MxClient!.State.ShouldBe(ConnectionState.Error);
|
||||
|
||||
proxy.ShouldFailRegister = false;
|
||||
await Task.Delay(2500);
|
||||
|
||||
service.MxClient.State.ShouldBe(ConnectionState.Connected);
|
||||
proxy.RegisterCallCount.ShouldBeGreaterThan(1);
|
||||
}
|
||||
finally
|
||||
{
|
||||
service.Stop();
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,41 @@
|
||||
using System.Diagnostics;
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Host;
|
||||
using ZB.MOM.WW.OtOpcUa.Host.Configuration;
|
||||
using ZB.MOM.WW.OtOpcUa.Tests.Helpers;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Tests.Wiring
|
||||
{
|
||||
/// <summary>
|
||||
/// Verifies: Start then Stop completes within 30 seconds. (SVC-004)
|
||||
/// </summary>
|
||||
public class ShutdownCompletesTest
|
||||
{
|
||||
/// <summary>
|
||||
/// Confirms that a started service can shut down within the required time budget.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void Shutdown_CompletesWithin30Seconds()
|
||||
{
|
||||
var config = new AppConfiguration
|
||||
{
|
||||
OpcUa = new OpcUaConfiguration { Port = 14841, GalaxyName = "TestGalaxy" },
|
||||
MxAccess = new MxAccessConfiguration { ClientName = "Test" },
|
||||
Dashboard = new DashboardConfiguration { Enabled = false }
|
||||
};
|
||||
|
||||
var proxy = new FakeMxProxy();
|
||||
var repo = new FakeGalaxyRepository();
|
||||
var service = new OpcUaService(config, proxy, repo);
|
||||
|
||||
service.Start();
|
||||
|
||||
var sw = Stopwatch.StartNew();
|
||||
service.Stop();
|
||||
sw.Stop();
|
||||
|
||||
sw.Elapsed.TotalSeconds.ShouldBeLessThan(30);
|
||||
}
|
||||
}
|
||||
}
|
||||
Reference in New Issue