chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)
Group all 69 projects into category subfolders under src/ and tests/ so the Rider Solution Explorer mirrors the module structure. Folders: Core, Server, Drivers (with a nested Driver CLIs subfolder), Client, Tooling. - Move every project folder on disk with git mv (history preserved as renames). - Recompute relative paths in 57 .csproj files: cross-category ProjectReferences, the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external mxaccessgw refs in Driver.Galaxy and its test project. - Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders. - Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL, integration, install). Build green (0 errors); unit tests pass. Docs left for a separate pass. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -0,0 +1,43 @@
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.Mitsubishi;
|
||||
|
||||
/// <summary>
|
||||
/// Tag map for the Mitsubishi MELSEC device class with a representative Modbus Device
|
||||
/// Assignment block mapping D0..D1023 → HR[0..1023]. Mirrors the behaviors in
|
||||
/// <c>mitsubishi.json</c> pymodbus profile and <c>docs/v2/mitsubishi.md</c>.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// MELSEC Modbus sites all have *different* device-assignment parameter blocks; this profile
|
||||
/// models the conventional default. Per-model differences (FX5U needs firmware ≥ 1.060 for
|
||||
/// Modbus server; QJ71MT91 lacks FC22/FC23; FX/iQ-F use octal X/Y while Q/L/iQ-R use hex)
|
||||
/// are handled in <see cref="MelsecAddress"/> (PR 59) and the per-model test files.
|
||||
/// </remarks>
|
||||
public static class MitsubishiProfile
|
||||
{
|
||||
/// <summary>
|
||||
/// Scratch HR the smoke test writes + reads. Address 200 mirrors the
|
||||
/// dl205/s7_1500/standard scratch range so one smoke test pattern works across every
|
||||
/// device profile the simulator supports.
|
||||
/// </summary>
|
||||
public const ushort SmokeHoldingRegister = 200;
|
||||
|
||||
/// <summary>Value the smoke test writes then reads back.</summary>
|
||||
public const short SmokeHoldingValue = 7890;
|
||||
|
||||
public static ModbusDriverOptions BuildOptions(string host, int port) => new()
|
||||
{
|
||||
Host = host,
|
||||
Port = port,
|
||||
UnitId = 1,
|
||||
Timeout = TimeSpan.FromSeconds(2),
|
||||
Tags =
|
||||
[
|
||||
new ModbusTagDefinition(
|
||||
Name: "Smoke_HReg200",
|
||||
Region: ModbusRegion.HoldingRegisters,
|
||||
Address: SmokeHoldingRegister,
|
||||
DataType: ModbusDataType.Int16,
|
||||
Writable: true),
|
||||
],
|
||||
Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
}
|
||||
Reference in New Issue