chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)
Group all 69 projects into category subfolders under src/ and tests/ so the Rider Solution Explorer mirrors the module structure. Folders: Core, Server, Drivers (with a nested Driver CLIs subfolder), Client, Tooling. - Move every project folder on disk with git mv (history preserved as renames). - Recompute relative paths in 57 .csproj files: cross-category ProjectReferences, the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external mxaccessgw refs in Driver.Galaxy and its test project. - Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders. - Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL, integration, install). Build green (0 errors); unit tests pass. Docs left for a separate pass. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -0,0 +1,56 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.DL205;
|
||||
|
||||
/// <summary>
|
||||
/// Verifies DL205/DL260 binary-coded-decimal register handling against the
|
||||
/// <c>dl205.json</c> pymodbus profile. HR[1072] = 0x1234 on the profile represents
|
||||
/// decimal 1234 (BCD nibbles). Reading it as <see cref="ModbusDataType.Int16"/> would
|
||||
/// return 0x1234 = 4660; the <see cref="ModbusDataType.Bcd16"/> path decodes 1234.
|
||||
/// </summary>
|
||||
[Collection(ModbusSimulatorCollection.Name)]
|
||||
[Trait("Category", "Integration")]
|
||||
[Trait("Device", "DL205")]
|
||||
public sealed class DL205BcdQuirkTests(ModbusSimulatorFixture sim)
|
||||
{
|
||||
[Fact]
|
||||
public async Task DL205_BCD16_decodes_HR1072_as_decimal_1234()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
|
||||
StringComparison.OrdinalIgnoreCase))
|
||||
{
|
||||
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping (standard profile does not seed HR[1072]).");
|
||||
}
|
||||
|
||||
var options = new ModbusDriverOptions
|
||||
{
|
||||
Host = sim.Host,
|
||||
Port = sim.Port,
|
||||
UnitId = 1,
|
||||
Timeout = TimeSpan.FromSeconds(2),
|
||||
Tags =
|
||||
[
|
||||
new ModbusTagDefinition("DL205_Count_Bcd",
|
||||
ModbusRegion.HoldingRegisters, Address: 1072,
|
||||
DataType: ModbusDataType.Bcd16, Writable: false),
|
||||
new ModbusTagDefinition("DL205_Count_Int16",
|
||||
ModbusRegion.HoldingRegisters, Address: 1072,
|
||||
DataType: ModbusDataType.Int16, Writable: false),
|
||||
],
|
||||
Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-bcd");
|
||||
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await driver.ReadAsync(["DL205_Count_Bcd", "DL205_Count_Int16"],
|
||||
TestContext.Current.CancellationToken);
|
||||
|
||||
results[0].StatusCode.ShouldBe(0u);
|
||||
results[0].Value.ShouldBe(1234, "DL205 BCD register 0x1234 represents decimal 1234 per the DirectLOGIC convention");
|
||||
|
||||
results[1].StatusCode.ShouldBe(0u);
|
||||
results[1].Value.ShouldBe((short)0x1234, "same register read as Int16 returns the raw 0x1234 = 4660 value — proves BCD path is distinct");
|
||||
}
|
||||
}
|
||||