Group all 69 projects into category subfolders under src/ and tests/ so the Rider Solution Explorer mirrors the module structure. Folders: Core, Server, Drivers (with a nested Driver CLIs subfolder), Client, Tooling. - Move every project folder on disk with git mv (history preserved as renames). - Recompute relative paths in 57 .csproj files: cross-category ProjectReferences, the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external mxaccessgw refs in Driver.Galaxy and its test project. - Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders. - Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL, integration, install). Build green (0 errors); unit tests pass. Docs left for a separate pass. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -0,0 +1,139 @@
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS;
|
||||
|
||||
/// <summary>
|
||||
/// Documented-API capability matrix — per CNC series, what ranges each
|
||||
/// <see cref="FocasAreaKind"/> supports. Authoritative source for the driver's
|
||||
/// pre-flight validation in <see cref="FocasDriver.InitializeAsync"/>.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <para>Ranges come from the Fanuc FOCAS Developer Kit documentation matrix
|
||||
/// (see <c>docs/v2/focas-version-matrix.md</c> for the authoritative copy with
|
||||
/// per-function citations). Numbers chosen to match what the FOCAS library
|
||||
/// accepts — a read against an address outside the documented range returns
|
||||
/// <c>EW_NUMBER</c> or <c>EW_PARAM</c> at the wire, which this driver maps to
|
||||
/// BadOutOfRange. Catching at init time surfaces the mismatch as a config
|
||||
/// error before any session is opened.</para>
|
||||
/// <para><see cref="FocasCncSeries.Unknown"/> is treated permissively: every
|
||||
/// address passes validation. Pre-matrix configs don't break on upgrade; new
|
||||
/// deployments are encouraged to declare a series in the device options.</para>
|
||||
/// </remarks>
|
||||
public static class FocasCapabilityMatrix
|
||||
{
|
||||
/// <summary>
|
||||
/// Check whether <paramref name="address"/> is accepted by a CNC of
|
||||
/// <paramref name="series"/>. Returns <c>null</c> on pass + a failure reason
|
||||
/// on reject — the driver surfaces the reason string verbatim when failing
|
||||
/// <c>InitializeAsync</c> so operators see the specific out-of-range without
|
||||
/// guessing.
|
||||
/// </summary>
|
||||
public static string? Validate(FocasCncSeries series, FocasAddress address)
|
||||
{
|
||||
if (series == FocasCncSeries.Unknown) return null;
|
||||
|
||||
return address.Kind switch
|
||||
{
|
||||
FocasAreaKind.Macro => ValidateMacro(series, address.Number),
|
||||
FocasAreaKind.Parameter => ValidateParameter(series, address.Number),
|
||||
FocasAreaKind.Pmc => ValidatePmc(series, address.PmcLetter, address.Number),
|
||||
_ => null,
|
||||
};
|
||||
}
|
||||
|
||||
/// <summary>Macro variable number accepted by a CNC series. Cites
|
||||
/// <c>cnc_rdmacro</c>/<c>cnc_wrmacro</c> in the Developer Kit.</summary>
|
||||
internal static (int min, int max) MacroRange(FocasCncSeries series) => series switch
|
||||
{
|
||||
// Common macros 1-33 + 100-199 + 500-999 universally; extended 10000+ only on
|
||||
// higher-end series. Using the extended ceiling per series per DevKit notes.
|
||||
FocasCncSeries.Sixteen_i => (0, 999),
|
||||
FocasCncSeries.Zero_i_D => (0, 999),
|
||||
FocasCncSeries.Zero_i_F or
|
||||
FocasCncSeries.Zero_i_MF or
|
||||
FocasCncSeries.Zero_i_TF => (0, 9999),
|
||||
FocasCncSeries.Thirty_i or
|
||||
FocasCncSeries.ThirtyOne_i or
|
||||
FocasCncSeries.ThirtyTwo_i => (0, 99999),
|
||||
FocasCncSeries.PowerMotion_i => (0, 999),
|
||||
_ => (0, int.MaxValue),
|
||||
};
|
||||
|
||||
/// <summary>Parameter number accepted; from <c>cnc_rdparam</c>/<c>cnc_wrparam</c>.
|
||||
/// Ranges reflect the highest-numbered parameter documented per series.</summary>
|
||||
internal static (int min, int max) ParameterRange(FocasCncSeries series) => series switch
|
||||
{
|
||||
FocasCncSeries.Sixteen_i => (0, 9999),
|
||||
FocasCncSeries.Zero_i_D or
|
||||
FocasCncSeries.Zero_i_F or
|
||||
FocasCncSeries.Zero_i_MF or
|
||||
FocasCncSeries.Zero_i_TF => (0, 14999),
|
||||
FocasCncSeries.Thirty_i or
|
||||
FocasCncSeries.ThirtyOne_i or
|
||||
FocasCncSeries.ThirtyTwo_i => (0, 29999),
|
||||
FocasCncSeries.PowerMotion_i => (0, 29999),
|
||||
_ => (0, int.MaxValue),
|
||||
};
|
||||
|
||||
/// <summary>PMC letters accepted per series. Legacy controllers omit F/M/C
|
||||
/// signal groups that 30i-family ladder programs use.</summary>
|
||||
internal static IReadOnlySet<string> PmcLetters(FocasCncSeries series) => series switch
|
||||
{
|
||||
FocasCncSeries.Sixteen_i => new HashSet<string>(StringComparer.OrdinalIgnoreCase) { "X", "Y", "R", "D" },
|
||||
FocasCncSeries.Zero_i_D => new HashSet<string>(StringComparer.OrdinalIgnoreCase) { "X", "Y", "R", "D", "E", "A" },
|
||||
FocasCncSeries.Zero_i_F or
|
||||
FocasCncSeries.Zero_i_MF or
|
||||
FocasCncSeries.Zero_i_TF => new HashSet<string>(StringComparer.OrdinalIgnoreCase) { "X", "Y", "F", "G", "R", "D", "E", "A", "M", "C" },
|
||||
FocasCncSeries.Thirty_i or
|
||||
FocasCncSeries.ThirtyOne_i or
|
||||
FocasCncSeries.ThirtyTwo_i => new HashSet<string>(StringComparer.OrdinalIgnoreCase) { "X", "Y", "F", "G", "R", "D", "E", "A", "M", "C", "K", "T" },
|
||||
FocasCncSeries.PowerMotion_i => new HashSet<string>(StringComparer.OrdinalIgnoreCase) { "X", "Y", "R", "D" },
|
||||
_ => new HashSet<string>(StringComparer.OrdinalIgnoreCase),
|
||||
};
|
||||
|
||||
/// <summary>PMC address-number ceiling per series. Multiplied by 8 to get bit
|
||||
/// count since PMC addresses are byte-addressed on read + bit-addressed on
|
||||
/// write — FocasAddress carries the bit separately.</summary>
|
||||
internal static int PmcMaxNumber(FocasCncSeries series) => series switch
|
||||
{
|
||||
FocasCncSeries.Sixteen_i => 999,
|
||||
FocasCncSeries.Zero_i_D => 1999,
|
||||
FocasCncSeries.Zero_i_F or
|
||||
FocasCncSeries.Zero_i_MF or
|
||||
FocasCncSeries.Zero_i_TF => 9999,
|
||||
FocasCncSeries.Thirty_i or
|
||||
FocasCncSeries.ThirtyOne_i or
|
||||
FocasCncSeries.ThirtyTwo_i => 59999,
|
||||
FocasCncSeries.PowerMotion_i => 1999,
|
||||
_ => int.MaxValue,
|
||||
};
|
||||
|
||||
private static string? ValidateMacro(FocasCncSeries series, int number)
|
||||
{
|
||||
var (min, max) = MacroRange(series);
|
||||
return (number < min || number > max)
|
||||
? $"Macro variable #{number} is outside the documented range [{min}, {max}] for {series}."
|
||||
: null;
|
||||
}
|
||||
|
||||
private static string? ValidateParameter(FocasCncSeries series, int number)
|
||||
{
|
||||
var (min, max) = ParameterRange(series);
|
||||
return (number < min || number > max)
|
||||
? $"Parameter #{number} is outside the documented range [{min}, {max}] for {series}."
|
||||
: null;
|
||||
}
|
||||
|
||||
private static string? ValidatePmc(FocasCncSeries series, string? letter, int number)
|
||||
{
|
||||
if (string.IsNullOrEmpty(letter)) return "PMC address is missing its letter prefix.";
|
||||
var letters = PmcLetters(series);
|
||||
if (!letters.Contains(letter))
|
||||
{
|
||||
var letterList = string.Join(", ", letters);
|
||||
return $"PMC letter '{letter}' is not supported on {series}. Accepted: {{{letterList}}}.";
|
||||
}
|
||||
var max = PmcMaxNumber(series);
|
||||
return number > max
|
||||
? $"PMC address {letter}{number} is outside the documented range [0, {max}] for {series}."
|
||||
: null;
|
||||
}
|
||||
}
|
||||
Reference in New Issue