chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)

Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.

- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
  the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
  mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
  integration, install).

Build green (0 errors); unit tests pass. Docs left for a separate pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-05-17 01:55:28 -04:00
parent 69f02fed7f
commit a25593a9c6
1044 changed files with 365 additions and 343 deletions
@@ -0,0 +1,62 @@
namespace ZB.MOM.WW.OtOpcUa.Driver.AbCip.PlcFamilies;
/// <summary>
/// Per-family libplctag defaults. Picked up at device-initialization time so each PLC
/// family gets the correct ConnectionSize, path semantics, and quirks applied without
/// the caller having to know the protocol-level differences.
/// </summary>
/// <remarks>
/// Mirrors the shape of the Modbus driver's per-family profiles (DL205, Siemens S7,
/// Mitsubishi MELSEC). ControlLogix is the baseline; each subsequent family is a delta.
/// Family-specific wire tests ship in PRs 912.
/// </remarks>
public sealed record AbCipPlcFamilyProfile(
string LibplctagPlcAttribute,
int DefaultConnectionSize,
string DefaultCipPath,
bool SupportsRequestPacking,
bool SupportsConnectedMessaging,
int MaxFragmentBytes)
{
/// <summary>Look up the profile for a configured family.</summary>
public static AbCipPlcFamilyProfile ForFamily(AbCipPlcFamily family) => family switch
{
AbCipPlcFamily.ControlLogix => ControlLogix,
AbCipPlcFamily.CompactLogix => CompactLogix,
AbCipPlcFamily.Micro800 => Micro800,
AbCipPlcFamily.GuardLogix => GuardLogix,
_ => ControlLogix,
};
public static readonly AbCipPlcFamilyProfile ControlLogix = new(
LibplctagPlcAttribute: "controllogix",
DefaultConnectionSize: 4002, // Large Forward Open; FW20+
DefaultCipPath: "1,0",
SupportsRequestPacking: true,
SupportsConnectedMessaging: true,
MaxFragmentBytes: 4000);
public static readonly AbCipPlcFamilyProfile CompactLogix = new(
LibplctagPlcAttribute: "compactlogix",
DefaultConnectionSize: 504, // 5069-L3x narrower buffer; safe baseline that never over-shoots
DefaultCipPath: "1,0",
SupportsRequestPacking: true,
SupportsConnectedMessaging: true,
MaxFragmentBytes: 500);
public static readonly AbCipPlcFamilyProfile Micro800 = new(
LibplctagPlcAttribute: "micro800",
DefaultConnectionSize: 488, // Micro800 hard cap
DefaultCipPath: "", // no backplane routing
SupportsRequestPacking: false,
SupportsConnectedMessaging: false, // unconnected-only on most models
MaxFragmentBytes: 484);
public static readonly AbCipPlcFamilyProfile GuardLogix = new(
LibplctagPlcAttribute: "controllogix", // wire protocol identical; safety partition is tag-level
DefaultConnectionSize: 4002,
DefaultCipPath: "1,0",
SupportsRequestPacking: true,
SupportsConnectedMessaging: true,
MaxFragmentBytes: 4000);
}