chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)

Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.

- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
  the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
  mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
  integration, install).

Build green (0 errors); unit tests pass. Docs left for a separate pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-05-17 01:55:28 -04:00
parent 69f02fed7f
commit a25593a9c6
1044 changed files with 365 additions and 343 deletions
@@ -0,0 +1,58 @@
using CliFx.Attributes;
using CliFx.Infrastructure;
using ZB.MOM.WW.OtOpcUa.Driver.Cli.Common;
namespace ZB.MOM.WW.OtOpcUa.Driver.TwinCAT.Cli.Commands;
/// <summary>
/// Probes a TwinCAT runtime: opens an ADS session, reads one symbol, prints driver health.
/// Use this first after configuring a new AMS route — it'll surface "no route" /
/// "port unreachable" / "AMS router down" errors up-front before you bring the OtOpcUa
/// server near the endpoint.
/// </summary>
[Command("probe", Description = "Verify the TwinCAT runtime is reachable and a sample symbol reads.")]
public sealed class ProbeCommand : TwinCATCommandBase
{
[CommandOption("symbol", 's', Description =
"Symbol path to probe. System-global examples: " +
"'TwinCAT_SystemInfoVarList._AppInfo.OnlineChangeCnt', 'MAIN.bRunning'. " +
"User-project: a GVL or program variable.",
IsRequired = true)]
public string SymbolPath { get; init; } = default!;
[CommandOption("type", Description = "Data type (default DInt — TwinCAT DINT maps to int32).")]
public TwinCATDataType DataType { get; init; } = TwinCATDataType.DInt;
public override async ValueTask ExecuteAsync(IConsole console)
{
ConfigureLogging();
var ct = console.RegisterCancellationHandler();
var probeTag = new TwinCATTagDefinition(
Name: "__probe",
DeviceHostAddress: Gateway,
SymbolPath: SymbolPath,
DataType: DataType,
Writable: false);
var options = BuildOptions([probeTag]);
await using var driver = new TwinCATDriver(options, DriverInstanceId);
try
{
await driver.InitializeAsync("{}", ct);
var snapshot = await driver.ReadAsync(["__probe"], ct);
var health = driver.GetHealth();
await console.Output.WriteLineAsync($"AMS: {AmsNetId}:{AmsPort}");
await console.Output.WriteLineAsync($"Health: {health.State}");
if (health.LastError is { } err)
await console.Output.WriteLineAsync($"Last error: {err}");
await console.Output.WriteLineAsync();
await console.Output.WriteLineAsync(SnapshotFormatter.Format(SymbolPath, snapshot[0]));
}
finally
{
await driver.ShutdownAsync(CancellationToken.None);
}
}
}