chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)
Group all 69 projects into category subfolders under src/ and tests/ so the Rider Solution Explorer mirrors the module structure. Folders: Core, Server, Drivers (with a nested Driver CLIs subfolder), Client, Tooling. - Move every project folder on disk with git mv (history preserved as renames). - Recompute relative paths in 57 .csproj files: cross-category ProjectReferences, the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external mxaccessgw refs in Driver.Galaxy and its test project. - Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders. - Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL, integration, install). Build green (0 errors); unit tests pass. Docs left for a separate pass. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -0,0 +1,56 @@
|
||||
using CliFx.Attributes;
|
||||
using CliFx.Infrastructure;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.Cli.Common;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.S7.Cli.Commands;
|
||||
|
||||
/// <summary>
|
||||
/// Probes an S7 endpoint: connects via S7.Net, reads one merker word, prints health.
|
||||
/// If the PLC is fresh out of TIA Portal the probe will surface
|
||||
/// <c>BadNotSupported</c> — PUT/GET communication has to be enabled in the hardware
|
||||
/// config for any S7-1200/1500 for the driver to get past the handshake.
|
||||
/// </summary>
|
||||
[Command("probe", Description = "Verify the S7 endpoint is reachable and a sample read succeeds.")]
|
||||
public sealed class ProbeCommand : S7CommandBase
|
||||
{
|
||||
[CommandOption("address", 'a', Description =
|
||||
"Probe address (default MW0 — merker word 0). DB1.DBW0 if your PLC project " +
|
||||
"reserves a fingerprint DB.")]
|
||||
public string Address { get; init; } = "MW0";
|
||||
|
||||
[CommandOption("type", Description = "Probe data type (default Int16).")]
|
||||
public S7DataType DataType { get; init; } = S7DataType.Int16;
|
||||
|
||||
public override async ValueTask ExecuteAsync(IConsole console)
|
||||
{
|
||||
ConfigureLogging();
|
||||
var ct = console.RegisterCancellationHandler();
|
||||
|
||||
var probeTag = new S7TagDefinition(
|
||||
Name: "__probe",
|
||||
Address: Address,
|
||||
DataType: DataType,
|
||||
Writable: false);
|
||||
var options = BuildOptions([probeTag]);
|
||||
|
||||
await using var driver = new S7Driver(options, DriverInstanceId);
|
||||
try
|
||||
{
|
||||
await driver.InitializeAsync("{}", ct);
|
||||
var snapshot = await driver.ReadAsync(["__probe"], ct);
|
||||
var health = driver.GetHealth();
|
||||
|
||||
await console.Output.WriteLineAsync($"Host: {Host}:{Port}");
|
||||
await console.Output.WriteLineAsync($"CPU: {CpuType} rack={Rack} slot={Slot}");
|
||||
await console.Output.WriteLineAsync($"Health: {health.State}");
|
||||
if (health.LastError is { } err)
|
||||
await console.Output.WriteLineAsync($"Last error: {err}");
|
||||
await console.Output.WriteLineAsync();
|
||||
await console.Output.WriteLineAsync(SnapshotFormatter.Format(Address, snapshot[0]));
|
||||
}
|
||||
finally
|
||||
{
|
||||
await driver.ShutdownAsync(CancellationToken.None);
|
||||
}
|
||||
}
|
||||
}
|
||||
Reference in New Issue