chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)

Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.

- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
  the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
  mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
  integration, install).

Build green (0 errors); unit tests pass. Docs left for a separate pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-05-17 01:55:28 -04:00
parent 69f02fed7f
commit a25593a9c6
1044 changed files with 365 additions and 343 deletions
@@ -0,0 +1,60 @@
using CliFx.Attributes;
using ZB.MOM.WW.OtOpcUa.Driver.Cli.Common;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Cli;
/// <summary>
/// Base for every Modbus CLI command. Carries the Modbus-TCP endpoint options
/// (host / port / unit-id) on top of <see cref="DriverCommandBase"/>'s verbose + timeout
/// + logging helpers, and exposes <see cref="BuildOptions"/> so each command can turn its
/// parsed flags into a <see cref="ModbusDriverOptions"/> ready to hand to the driver ctor.
/// </summary>
public abstract class ModbusCommandBase : DriverCommandBase
{
[CommandOption("host", 'h', Description = "Modbus-TCP server hostname or IP", IsRequired = true)]
public string Host { get; init; } = default!;
[CommandOption("port", 'p', Description = "Modbus-TCP port (default 502)")]
public int Port { get; init; } = 502;
[CommandOption("unit-id", 'U', Description = "Modbus unit / slave ID (1-247, default 1)")]
public byte UnitId { get; init; } = 1;
[CommandOption("timeout-ms", Description = "Per-PDU timeout in milliseconds (default 2000)")]
public int TimeoutMs { get; init; } = 2000;
[CommandOption("disable-reconnect", Description =
"Disable the built-in mid-transaction reconnect-and-retry. Matches the driver's " +
"AutoReconnect=false setting — use when diagnosing socket teardown behaviour.")]
public bool DisableAutoReconnect { get; init; }
/// <inheritdoc />
public override TimeSpan Timeout
{
get => TimeSpan.FromMilliseconds(TimeoutMs);
init { /* driven by TimeoutMs property; setter required to satisfy base's init contract */ }
}
/// <summary>
/// Construct a <see cref="ModbusDriverOptions"/> with the endpoint fields this base
/// collected + whatever <paramref name="tags"/> the subclass declares. Probe is
/// disabled — CLI runs are one-shot, the probe loop would race the operator's
/// command against its own keep-alive reads.
/// </summary>
protected ModbusDriverOptions BuildOptions(IReadOnlyList<ModbusTagDefinition> tags) => new()
{
Host = Host,
Port = Port,
UnitId = UnitId,
Timeout = Timeout,
AutoReconnect = !DisableAutoReconnect,
Tags = tags,
Probe = new ModbusProbeOptions { Enabled = false },
};
/// <summary>
/// Short instance id used in Serilog output so operators running the CLI against
/// multiple endpoints in parallel can distinguish the logs.
/// </summary>
protected string DriverInstanceId => $"modbus-cli-{Host}:{Port}";
}