chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)

Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.

- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
  the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
  mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
  integration, install).

Build green (0 errors); unit tests pass. Docs left for a separate pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-05-17 01:55:28 -04:00
parent 69f02fed7f
commit a25593a9c6
1044 changed files with 365 additions and 343 deletions
@@ -0,0 +1,118 @@
using System.Globalization;
using CliFx.Attributes;
using CliFx.Infrastructure;
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
using ZB.MOM.WW.OtOpcUa.Driver.Cli.Common;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Cli.Commands;
/// <summary>
/// Write one value to a Modbus coil or holding register. Mirrors <see cref="ReadCommand"/>'s
/// region / address / type flags + adds <c>--value</c>. Input parsing respects the
/// declared <c>--type</c> so you can write <c>--value=3.14 --type=Float32</c> without
/// hex-encoding floats. The write is non-idempotent by default (driver's
/// <c>WriteIdempotent=false</c>) — replay is the operator's choice, not the driver's.
/// </summary>
[Command("write", Description = "Write a single Modbus coil or holding register.")]
public sealed class WriteCommand : ModbusCommandBase
{
[CommandOption("region", 'r', Description =
"Coils or HoldingRegisters (the only writable regions per the protocol spec).",
IsRequired = true)]
public ModbusRegion Region { get; init; }
[CommandOption("address", 'a', Description =
"Zero-based address within the region.", IsRequired = true)]
public ushort Address { get; init; }
[CommandOption("type", 't', Description =
"Bool / Int16 / UInt16 / Int32 / UInt32 / Int64 / UInt64 / Float32 / Float64 / " +
"BitInRegister / String / Bcd16 / Bcd32", IsRequired = true)]
public ModbusDataType DataType { get; init; }
[CommandOption("value", 'v', Description =
"Value to write. Parsed per --type (booleans accept true/false/0/1).",
IsRequired = true)]
public string Value { get; init; } = default!;
[CommandOption("byte-order", Description =
"BigEndian (default, ABCD) or WordSwap (CDAB). Ignored for single-register types.")]
public ModbusByteOrder ByteOrder { get; init; } = ModbusByteOrder.BigEndian;
[CommandOption("bit-index", Description =
"For type=BitInRegister: which bit of the holding register (0-15, LSB-first).")]
public byte BitIndex { get; init; }
[CommandOption("string-length", Description =
"For type=String: character count (2 per register, rounded up).")]
public ushort StringLength { get; init; }
[CommandOption("string-byte-order", Description =
"For type=String: HighByteFirst (standard) or LowByteFirst (DirectLOGIC).")]
public ModbusStringByteOrder StringByteOrder { get; init; } = ModbusStringByteOrder.HighByteFirst;
public override async ValueTask ExecuteAsync(IConsole console)
{
ConfigureLogging();
var ct = console.RegisterCancellationHandler();
if (Region is not (ModbusRegion.Coils or ModbusRegion.HoldingRegisters))
throw new CliFx.Exceptions.CommandException(
$"Region '{Region}' is read-only in the Modbus spec; writes require Coils or HoldingRegisters.");
var tagName = ReadCommand.SynthesiseTagName(Region, Address, DataType);
var tag = new ModbusTagDefinition(
Name: tagName,
Region: Region,
Address: Address,
DataType: DataType,
Writable: true,
ByteOrder: ByteOrder,
BitIndex: BitIndex,
StringLength: StringLength,
StringByteOrder: StringByteOrder);
var options = BuildOptions([tag]);
var parsed = ParseValue(Value, DataType);
await using var driver = new ModbusDriver(options, DriverInstanceId);
try
{
await driver.InitializeAsync("{}", ct);
var results = await driver.WriteAsync([new WriteRequest(tagName, parsed)], ct);
await console.Output.WriteLineAsync(SnapshotFormatter.FormatWrite(tagName, results[0]));
}
finally
{
await driver.ShutdownAsync(CancellationToken.None);
}
}
/// <summary>
/// Parse the operator's <c>--value</c> string into the CLR type the driver expects
/// for the declared <see cref="ModbusDataType"/>. Uses invariant culture everywhere
/// so <c>3.14</c> and <c>3,14</c> don't swap meaning between runs.
/// </summary>
internal static object ParseValue(string raw, ModbusDataType type) => type switch
{
ModbusDataType.Bool or ModbusDataType.BitInRegister => ParseBool(raw),
ModbusDataType.Int16 => short.Parse(raw, CultureInfo.InvariantCulture),
ModbusDataType.UInt16 or ModbusDataType.Bcd16 => ushort.Parse(raw, CultureInfo.InvariantCulture),
ModbusDataType.Int32 => int.Parse(raw, CultureInfo.InvariantCulture),
ModbusDataType.UInt32 or ModbusDataType.Bcd32 => uint.Parse(raw, CultureInfo.InvariantCulture),
ModbusDataType.Int64 => long.Parse(raw, CultureInfo.InvariantCulture),
ModbusDataType.UInt64 => ulong.Parse(raw, CultureInfo.InvariantCulture),
ModbusDataType.Float32 => float.Parse(raw, CultureInfo.InvariantCulture),
ModbusDataType.Float64 => double.Parse(raw, CultureInfo.InvariantCulture),
ModbusDataType.String => raw,
_ => throw new CliFx.Exceptions.CommandException($"Unsupported DataType '{type}' for write."),
};
private static bool ParseBool(string raw) => raw.Trim().ToLowerInvariant() switch
{
"1" or "true" or "on" or "yes" => true,
"0" or "false" or "off" or "no" => false,
_ => throw new CliFx.Exceptions.CommandException(
$"Boolean value '{raw}' is not recognised. Use true/false, 1/0, on/off, or yes/no."),
};
}