chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)

Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.

- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
  the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
  mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
  integration, install).

Build green (0 errors); unit tests pass. Docs left for a separate pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-05-17 01:55:28 -04:00
parent 69f02fed7f
commit a25593a9c6
1044 changed files with 365 additions and 343 deletions
@@ -0,0 +1,55 @@
using CliFx.Attributes;
using CliFx.Infrastructure;
using ZB.MOM.WW.OtOpcUa.Driver.Cli.Common;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Cli.Commands;
/// <summary>
/// Probes a Modbus-TCP endpoint: opens a socket via <see cref="ModbusDriver"/>'s
/// <c>InitializeAsync</c>, issues a single FC03 at the configured probe address, and
/// prints the driver's <c>GetHealth()</c>. Fastest way to answer "is the PLC up + talking
/// Modbus on this host:port?".
/// </summary>
[Command("probe", Description = "Verify the Modbus-TCP endpoint is reachable and speaks Modbus.")]
public sealed class ProbeCommand : ModbusCommandBase
{
[CommandOption("probe-address", Description =
"Holding-register address used as the cheap-read probe (default 0). Some PLCs lock " +
"register 0 — set this to a known-good address on your device.")]
public ushort ProbeAddress { get; init; }
public override async ValueTask ExecuteAsync(IConsole console)
{
ConfigureLogging();
var ct = console.RegisterCancellationHandler();
// Build with one probe tag + Probe.Enabled=false so InitializeAsync connects the
// transport, we issue a single read to verify the device responds, then shut down.
var probeTag = new ModbusTagDefinition(
Name: "__probe",
Region: ModbusRegion.HoldingRegisters,
Address: ProbeAddress,
DataType: ModbusDataType.UInt16);
var options = BuildOptions([probeTag]);
await using var driver = new ModbusDriver(options, DriverInstanceId);
try
{
await driver.InitializeAsync("{}", ct);
var snapshot = await driver.ReadAsync(["__probe"], ct);
var health = driver.GetHealth();
await console.Output.WriteLineAsync($"Host: {Host}:{Port} (unit {UnitId})");
await console.Output.WriteLineAsync($"Health: {health.State}");
if (health.LastError is { } err)
await console.Output.WriteLineAsync($"Last error: {err}");
await console.Output.WriteLineAsync();
await console.Output.WriteLineAsync(
SnapshotFormatter.Format($"HR[{ProbeAddress}]", snapshot[0]));
}
finally
{
await driver.ShutdownAsync(CancellationToken.None);
}
}
}