chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)

Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.

- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
  the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
  mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
  integration, install).

Build green (0 errors); unit tests pass. Docs left for a separate pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-05-17 01:55:28 -04:00
parent 69f02fed7f
commit a25593a9c6
1044 changed files with 365 additions and 343 deletions
@@ -0,0 +1,57 @@
using CliFx.Attributes;
using ZB.MOM.WW.OtOpcUa.Driver.Cli.Common;
namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli;
/// <summary>
/// Base for every FOCAS CLI command. Carries the CNC endpoint options
/// (host / port / series) + exposes <see cref="BuildOptions"/> so each command
/// can synthesise a <see cref="FocasDriverOptions"/> with one device + one tag.
/// </summary>
public abstract class FocasCommandBase : DriverCommandBase
{
[CommandOption("cnc-host", 'h', Description =
"CNC IP address or hostname. FOCAS-over-EIP listens on port 8193 by default.",
IsRequired = true)]
public string CncHost { get; init; } = default!;
[CommandOption("cnc-port", 'p', Description = "FOCAS TCP port (default 8193).")]
public int CncPort { get; init; } = 8193;
[CommandOption("series", 's', Description =
"CNC series: Unknown / Zero_i_D / Zero_i_F / Zero_i_MF / Zero_i_TF / Sixteen_i / " +
"Thirty_i / ThirtyOne_i / ThirtyTwo_i / PowerMotion_i (default Unknown).")]
public FocasCncSeries Series { get; init; } = FocasCncSeries.Unknown;
[CommandOption("timeout-ms", Description = "Per-operation timeout in ms (default 2000).")]
public int TimeoutMs { get; init; } = 2000;
/// <inheritdoc />
public override TimeSpan Timeout
{
get => TimeSpan.FromMilliseconds(TimeoutMs);
init { /* driven by TimeoutMs */ }
}
/// <summary>Canonical FOCAS host-address string, shape <c>focas://host:port</c>.</summary>
protected string HostAddress => $"focas://{CncHost}:{CncPort}";
/// <summary>
/// Build a <see cref="FocasDriverOptions"/> with the CNC target this base collected
/// + the tag list a subclass supplies. Probe disabled; the driver's default managed
/// wire client opens a TCP:8193 session to the CNC and surfaces unreachable endpoints
/// as <c>BadCommunicationError</c>.
/// </summary>
protected FocasDriverOptions BuildOptions(IReadOnlyList<FocasTagDefinition> tags) => new()
{
Devices = [new FocasDeviceOptions(
HostAddress: HostAddress,
DeviceName: $"cli-{CncHost}:{CncPort}",
Series: Series)],
Tags = tags,
Timeout = Timeout,
Probe = new FocasProbeOptions { Enabled = false },
};
protected string DriverInstanceId => $"focas-cli-{CncHost}:{CncPort}";
}