Phase 3 PR 43 — Swap ModbusPal to pymodbus for the integration-test simulator. Replaces the .xmpp profiles shipped in PR 42 with pymodbus 3.13.0 ModbusSimulatorServer JSON configs in tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/. Substantive reasons for the swap (rationale block in the test-plan doc): ModbusPal 1.6b is abandoned (last release ~2019), Java GUI-only with no headless mode in the official JAR, and only exposes 2 of the 4 standard Modbus tables (holding_registers + coils — no input_registers, no discrete_inputs). pymodbus is current stable, pure Python CLI (pip install pymodbus[simulator]==3.13.0), exposes all four tables, has built-in declarative actions (increment / random / timestamp / uptime) for dynamic registers, supports custom Python actions for anything more complex, and ships an optional aiohttp-based web UI / REST API for live inspection. Pip-installable on Windows; sidesteps the privileged-port admin requirement by defaulting to TCP 5020.

ModbusSimulatorFixture default port bumped from 502 to 5020 to match the pymodbus convention. Override via MODBUS_SIM_ENDPOINT for a real PLC on its native 502. Skip-message updated to point at the new Pymodbus\serve.ps1 wrapper instead of 'start ModbusPal'. csproj <None Update> rule swapped from ModbusPal/** to Pymodbus/** so the new JSON profiles + serve.ps1 + README copy to test-output as PreserveNewest.
standard.json — generic Modbus TCP server, slave id 1, port 5020, shared blocks=false (independent coils + HR address spaces, more textbook-PLC-like). HR[0..31] seeded with address-as-value via per-register uint16 entries, HR[100] auto-increments via the built-in increment action with parameters minval=0/maxval=65535 (drives subscribe-and-receive integration tests so they have a register that ticks without a write — pymodbus's increment ticks per-access not wall-clock, which is good enough for a 250ms-poll test), HR[200..209] scratch range left at 0 for write tests, coils 0..31 alternating, coils 100..109 scratch. write list covers 0..1023 so any test address is mutable.
dl205.json — AutomationDirect DirectLOGIC DL205/DL260 quirk simulator, slave id 1, port 5020, shared blocks=true (matches DL series memory model where coils/DI/HR overlay the same word address space). Each quirky register seeded with the pre-computed raw uint16 value documented in docs/v2/dl205.md, with an inline _quirk JSON-comment naming the behavior so future-me reading the file knows why HR[1040]=25928 means 'H' lo / 'e' hi (the user's headline string-byte-order finding). Encoded quirks: V0 marker at HR[0]=0xCAFE; V2000 at HR[1024]=0x2000; V40400 at HR[8448]=0x4040; 'Hello' string at HR[1040..1042] first-char-low-byte; Float32 1.5f at HR[1056..1057] in CDAB word order (low word first); BCD register at HR[1072]=0x1234; FC03-128-cap block at HR[1280..1407]; Y0/C0 coil markers at 2048/3072; scratch C-relays at 4000..4007.
serve.ps1 wrapper — pwsh script with a -Profile {standard|dl205} parameter switch. Validates pymodbus.simulator is on PATH (clearer message than the raw CommandNotFoundException), validates the profile JSON exists, builds the right --modbus_server/--modbus_device/--json_file/--http_port arg list, and execs pymodbus.simulator in the foreground. -HttpPort 0 disables the web UI. Foreground exec lets the operator Ctrl+C to stop without an extra control script.
README.md fully rewritten for pymodbus: install command (pip install 'pymodbus[simulator]==3.13.0' — pinned for reproducibility, [simulator] extra pulls aiohttp), per-profile reference tables, the same DL205 quirk → register table from PR 42 but adjusted for pymodbus paths, what's-NEW-vs-ModbusPal section (all four tables, raw uint16 seeding, declarative actions, custom Python action modules, headless, web UI, maintained), trade-offs section (float32-as-two-uint16s for explicit CDAB control, increment ticks per-access not wall-clock, shared-blocks mode for DL205 vs separate for Standard), file-format quick reference for hand-authoring more profiles. References pinned to the pymodbus readthedocs simulator/config + REST API pages.
docs/v2/modbus-test-plan.md harness section rewritten with the swap rationale; PR-history list updated to mark PR 42 SUPERSEDED by PR 43 and call out PR 44+ as the per-quirk implementation track. Test-conventions bullet about 'don't depend on ModbusPal state between tests' generalized to 'don't depend on simulator state' and a note added that pymodbus's REST API can reset state between facts if a test ever needs it.
DL205Profile.cs and DL205SmokeTests.cs xml-doc updated to reference pymodbus / dl205.json instead of ModbusPal / DL205.xmpp.
Functional validation deferred — Python isn't installed on this dev box (winget search returned no matches for Python.Python.3 exact). JSON parses structurally (PowerShell ConvertFrom-Json clean on both files), build clean, .json + serve.ps1 + README all copy to test-output as expected. User installs pymodbus when they want to actually run the simulator end-to-end; if pymodbus rejects the config the README's reference link to pymodbus's simulator/config schema doc is the right next stop.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-04-18 20:35:26 -04:00
parent c59ac9e52d
commit a05b84858d
11 changed files with 459 additions and 498 deletions

View File

@@ -3,8 +3,9 @@ using System.Net.Sockets;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests;
/// <summary>
/// Reachability probe for a Modbus TCP simulator (ModbusPal or a real PLC). Parses
/// <c>MODBUS_SIM_ENDPOINT</c> (default <c>localhost:502</c>) and TCP-connects once at
/// Reachability probe for a Modbus TCP simulator (pymodbus-driven, see
/// <c>Pymodbus/serve.ps1</c>) or a real PLC. Parses
/// <c>MODBUS_SIM_ENDPOINT</c> (default <c>localhost:5020</c> per PR 43) and TCP-connects once at
/// fixture construction. Each test checks <see cref="SkipReason"/> and calls
/// <c>Assert.Skip</c> when the endpoint was unreachable, so a dev box without a running
/// simulator still passes `dotnet test` cleanly — matches the Galaxy live-smoke pattern in
@@ -25,7 +26,11 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests;
/// </remarks>
public sealed class ModbusSimulatorFixture : IAsyncDisposable
{
private const string DefaultEndpoint = "localhost:502";
// PR 43: default port is 5020 (pymodbus convention) instead of 502 (Modbus standard).
// Picking 5020 sidesteps the privileged-port admin requirement on Windows + matches the
// port baked into the pymodbus simulator JSON profiles in Pymodbus/. Override with
// MODBUS_SIM_ENDPOINT to point at a real PLC on its native port 502.
private const string DefaultEndpoint = "localhost:5020";
private const string EndpointEnvVar = "MODBUS_SIM_ENDPOINT";
public string Host { get; }
@@ -46,13 +51,15 @@ public sealed class ModbusSimulatorFixture : IAsyncDisposable
if (!task.Wait(TimeSpan.FromSeconds(2)) || !client.Connected)
{
SkipReason = $"Modbus simulator at {Host}:{Port} did not accept a TCP connection within 2s. " +
$"Start ModbusPal (or override {EndpointEnvVar}) and re-run.";
$"Start the pymodbus simulator (Pymodbus\\serve.ps1 -Profile standard) " +
$"or override {EndpointEnvVar}, then re-run.";
}
}
catch (Exception ex)
{
SkipReason = $"Modbus simulator at {Host}:{Port} unreachable: {ex.GetType().Name}: {ex.Message}. " +
$"Start ModbusPal (or override {EndpointEnvVar}) and re-run.";
$"Start the pymodbus simulator (Pymodbus\\serve.ps1 -Profile standard) " +
$"or override {EndpointEnvVar}, then re-run.";
}
}