refactor(driver-s7): extract S7DriverOptions to .Contracts with parallel CpuType enum
Introduces Driver.S7.Contracts (dependency-free POCO project) and moves S7DriverOptions / S7ProbeOptions / S7TagDefinition / S7DataType into it. Adds S7CpuType enum mirroring S7.Net.CpuType exactly (7 values with explicit integer codes). Runtime S7CpuTypeMap bridges S7CpuType → S7.Net.CpuType at the single Plc construction site in S7Driver.InitializeAsync. S7DriverFactoryExtensions and S7CommandBase updated to use S7CpuType; test files updated to match (S7_1500Profile, S7DriverScaffoldTests). AdminUI can now reference Driver.S7.Contracts without pulling in S7netplus.
This commit is contained in:
@@ -0,0 +1,18 @@
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.S7;
|
||||
|
||||
/// <summary>
|
||||
/// CPU family used during S7 ISO-on-TCP handshake. Mirrors the value set of
|
||||
/// <c>S7.Net.CpuType</c> (NuGet package S7netplus) so the contracts project stays
|
||||
/// dependency-free. The runtime <c>S7Driver</c> maps this to the underlying
|
||||
/// <c>S7.Net.CpuType</c> via <c>S7CpuTypeMap</c>.
|
||||
/// </summary>
|
||||
public enum S7CpuType
|
||||
{
|
||||
S7200 = 0,
|
||||
Logo0BA8 = 1,
|
||||
S7200Smart = 2,
|
||||
S7300 = 10,
|
||||
S7400 = 20,
|
||||
S71200 = 30,
|
||||
S71500 = 40,
|
||||
}
|
||||
@@ -0,0 +1,119 @@
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.S7;
|
||||
|
||||
/// <summary>
|
||||
/// Siemens S7 native (S7comm / ISO-on-TCP port 102) driver configuration. Bound from the
|
||||
/// driver's <c>DriverConfig</c> JSON at <c>DriverHost.RegisterAsync</c>. Unlike the Modbus
|
||||
/// driver the S7 driver uses the PLC's *native* protocol — port 102 ISO-on-TCP rather
|
||||
/// than Modbus's 502, and S7-specific area codes (DB, M, I, Q) rather than holding-
|
||||
/// register / coil tables.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <para>
|
||||
/// The driver requires <b>PUT/GET communication enabled</b> in the TIA Portal
|
||||
/// hardware config for S7-1200/1500. The factory default disables PUT/GET access,
|
||||
/// so a driver configured against a freshly-flashed CPU will see a hard error
|
||||
/// (S7.Net surfaces it as <c>Plc.ReadAsync</c> returning <c>ErrorCode.Accessing</c>).
|
||||
/// The driver maps that specifically to <c>BadNotSupported</c> and flags it as a
|
||||
/// configuration alert rather than a transient fault — blind Polly retry is wasted
|
||||
/// effort when the PLC will keep refusing every request.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// See <c>docs/v2/driver-specs.md</c> §5 for the full specification.
|
||||
/// </para>
|
||||
/// </remarks>
|
||||
public sealed class S7DriverOptions
|
||||
{
|
||||
/// <summary>PLC IP address or hostname.</summary>
|
||||
public string Host { get; init; } = "127.0.0.1";
|
||||
|
||||
/// <summary>TCP port. ISO-on-TCP is 102 on every S7 model; override only for unusual NAT setups.</summary>
|
||||
public int Port { get; init; } = 102;
|
||||
|
||||
/// <summary>
|
||||
/// CPU family. Determines the ISO-TSAP slot byte that S7.Net uses during connection
|
||||
/// setup — pick the family that matches the target PLC exactly.
|
||||
/// </summary>
|
||||
public S7CpuType CpuType { get; init; } = S7CpuType.S71500;
|
||||
|
||||
/// <summary>
|
||||
/// Hardware rack number. Almost always 0; relevant only for distributed S7-400 racks
|
||||
/// with multiple CPUs.
|
||||
/// </summary>
|
||||
public short Rack { get; init; } = 0;
|
||||
|
||||
/// <summary>
|
||||
/// CPU slot. Conventions per family: S7-300 = slot 2, S7-400 = slot 2 or 3,
|
||||
/// S7-1200 / S7-1500 = slot 0 (onboard PN). S7.Net uses this to build the remote
|
||||
/// TSAP. Wrong slot → connection refused during handshake.
|
||||
/// </summary>
|
||||
public short Slot { get; init; } = 0;
|
||||
|
||||
/// <summary>Connect + per-operation timeout.</summary>
|
||||
public TimeSpan Timeout { get; init; } = TimeSpan.FromSeconds(5);
|
||||
|
||||
/// <summary>Pre-declared tag map. S7 has a symbol-table protocol but S7.Net does not expose it, so the driver operates off a static tag list configured per-site. Address grammar documented in S7AddressParser (PR 63).</summary>
|
||||
public IReadOnlyList<S7TagDefinition> Tags { get; init; } = [];
|
||||
|
||||
/// <summary>
|
||||
/// Background connectivity-probe settings. When enabled, the driver runs a tick loop
|
||||
/// that issues <c>S7.Net.Plc.ReadStatusAsync</c> (a CPU-status PDU) every
|
||||
/// <see cref="S7ProbeOptions.Interval"/> and raises <c>OnHostStatusChanged</c> on
|
||||
/// Running ↔ Stopped transitions.
|
||||
/// </summary>
|
||||
public S7ProbeOptions Probe { get; init; } = new();
|
||||
}
|
||||
|
||||
public sealed class S7ProbeOptions
|
||||
{
|
||||
/// <summary>Gets or sets a value indicating whether probing is enabled.</summary>
|
||||
public bool Enabled { get; init; } = true;
|
||||
/// <summary>Gets or sets the probe interval.</summary>
|
||||
public TimeSpan Interval { get; init; } = TimeSpan.FromSeconds(5);
|
||||
/// <summary>Gets or sets the probe timeout.</summary>
|
||||
public TimeSpan Timeout { get; init; } = TimeSpan.FromSeconds(2);
|
||||
|
||||
// Driver.S7-012: ProbeAddress was configured and documented but was never read by the
|
||||
// probe loop. ProbeLoopAsync uses S7.Net's ReadStatusAsync (a CPU-status PDU), not a
|
||||
// DB/Merker read — it does not consume an explicit address. Rather than ship dead config
|
||||
// surface, ProbeAddress has been removed. The liveness check is purely ReadStatusAsync-based.
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// One S7 variable as exposed by the driver. Addresses use S7.Net syntax — see
|
||||
/// <c>S7AddressParser</c> (PR 63) for the grammar.
|
||||
/// </summary>
|
||||
/// <param name="Name">Tag name; OPC UA browse name + driver full reference.</param>
|
||||
/// <param name="Address">S7 address string, e.g. <c>DB1.DBW0</c>, <c>M0.0</c>, <c>I0.0</c>, <c>QD4</c>. Grammar documented in <c>S7AddressParser</c> (PR 63).</param>
|
||||
/// <param name="DataType">Logical data type — drives the underlying S7.Net read/write width.</param>
|
||||
/// <param name="Writable">When true the driver accepts writes for this tag.</param>
|
||||
/// <param name="StringLength">For <c>DataType = String</c>: S7-string max length. Default 254 (S7 max).</param>
|
||||
/// <param name="WriteIdempotent">
|
||||
/// Per <c>docs/v2/plan.md</c> decisions #44, #45, #143 — flag a tag as safe to replay on
|
||||
/// write timeout / failure. Default <c>false</c>; writes do not auto-retry. Safe candidates
|
||||
/// on S7: DB word/dword set-points holding analog values, configuration DBs where the same
|
||||
/// value can be written again without side-effects. Unsafe: M (merker) bits or Q (output)
|
||||
/// coils that drive edge-triggered routines in the PLC program.
|
||||
/// </param>
|
||||
public sealed record S7TagDefinition(
|
||||
string Name,
|
||||
string Address,
|
||||
S7DataType DataType,
|
||||
bool Writable = true,
|
||||
int StringLength = 254,
|
||||
bool WriteIdempotent = false);
|
||||
|
||||
public enum S7DataType
|
||||
{
|
||||
Bool,
|
||||
Byte,
|
||||
Int16,
|
||||
UInt16,
|
||||
Int32,
|
||||
UInt32,
|
||||
Int64,
|
||||
UInt64,
|
||||
Float32,
|
||||
Float64,
|
||||
String,
|
||||
DateTime,
|
||||
}
|
||||
+12
@@ -0,0 +1,12 @@
|
||||
<Project Sdk="Microsoft.NET.Sdk">
|
||||
|
||||
<PropertyGroup>
|
||||
<TargetFramework>net10.0</TargetFramework>
|
||||
<Nullable>enable</Nullable>
|
||||
<ImplicitUsings>enable</ImplicitUsings>
|
||||
<TreatWarningsAsErrors>true</TreatWarningsAsErrors>
|
||||
</PropertyGroup>
|
||||
|
||||
<!-- NO PackageReference. NO ProjectReference. -->
|
||||
|
||||
</Project>
|
||||