Merge branch 'master' into remed/lane-E
This commit is contained in:
@@ -72,7 +72,13 @@ public sealed class TelemetryDialOptions
|
||||
/// <summary>How often central refreshes its set of dialable node contacts, in seconds.</summary>
|
||||
public int ContactRefreshSeconds { get; set; } = 60;
|
||||
|
||||
/// <summary>Per-call deadline for a gRPC telemetry dial, in seconds.</summary>
|
||||
/// <summary>
|
||||
/// Deadline, in seconds, for a gRPC telemetry dial to deliver its first event. A live node answers a
|
||||
/// fresh subscribe at once (it replays its health/resilience snapshots), so a dial still silent at the
|
||||
/// deadline is one that never connected — it is cancelled and re-dialled. Bounds establishment only;
|
||||
/// an established stream is kept alive by HTTP/2 keepalive pings, not by this value. Values below 1
|
||||
/// are treated as 1.
|
||||
/// </summary>
|
||||
public int CallTimeoutSeconds { get; set; } = 30;
|
||||
}
|
||||
|
||||
|
||||
@@ -188,6 +188,13 @@ public sealed class DiscoveryDriverBrowser : IUniversalDriverBrowser
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Final teardown of a throwaway capture/probe driver: a bounded <see cref="IDriver.ShutdownAsync"/>
|
||||
/// followed by a bounded dispose. The dispose is NOT optional and runs even after a failed or timed-out
|
||||
/// shutdown: a Galaxy driver's <c>ShutdownAsync</c> releases none of its gRPC runtime (channels, MX
|
||||
/// session, stream loops) — only <c>DisposeAsync</c> does — so a browse that stopped at shutdown leaked a
|
||||
/// full runtime per <c>/raw</c> browse and per <see cref="CanBrowse"/> probe (02/L1, 06/G-1).
|
||||
/// </summary>
|
||||
private async Task BoundedShutdownAsync(IDriver driver, string driverType)
|
||||
{
|
||||
try
|
||||
@@ -199,7 +206,25 @@ public sealed class DiscoveryDriverBrowser : IUniversalDriverBrowser
|
||||
catch (Exception ex)
|
||||
{
|
||||
_logger.LogWarning(ex,
|
||||
"Browse-capture shutdown for {DriverType} failed/timed out; instance abandoned", driverType);
|
||||
"Browse-capture shutdown for {DriverType} failed/timed out; disposing the instance anyway", driverType);
|
||||
}
|
||||
|
||||
try
|
||||
{
|
||||
switch (driver)
|
||||
{
|
||||
case IAsyncDisposable asyncDisposable:
|
||||
await asyncDisposable.DisposeAsync().AsTask().WaitAsync(_shutdownTimeout).ConfigureAwait(false);
|
||||
break;
|
||||
case IDisposable disposable:
|
||||
disposable.Dispose();
|
||||
break;
|
||||
}
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
_logger.LogWarning(ex,
|
||||
"Browse-capture dispose for {DriverType} failed/timed out; instance abandoned", driverType);
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
@@ -28,6 +28,10 @@
|
||||
Directory.Packages.props. This is the one project where the DataProtection chain
|
||||
enters the repo; every other consumer reaches it through a ProjectReference here. -->
|
||||
<PackageReference Include="System.Security.Cryptography.Xml"/>
|
||||
<!-- Surgical transitive pin — see the System.Security.Cryptography.Pkcs block in
|
||||
Directory.Packages.props. Microsoft.Data.SqlClient (via EFCore.SqlServer) enters here
|
||||
too and pulls a vulnerable Pkcs 9.0.4 wherever the shared framework prunes the Xml chain. -->
|
||||
<PackageReference Include="System.Security.Cryptography.Pkcs"/>
|
||||
<PackageReference Include="Microsoft.Extensions.Configuration.Abstractions"/>
|
||||
<PackageReference Include="Microsoft.Extensions.Logging.Abstractions"/>
|
||||
<PackageReference Include="Polly.Core"/>
|
||||
|
||||
+68
-21
@@ -67,6 +67,12 @@ public sealed class GatewayHistorianDataSource : IHistorianDataSource, IAsyncDis
|
||||
/// <summary>The tie-cluster limit the crowding re-reads honour — exposed so the factory wiring is testable.</summary>
|
||||
internal int MaxPreWindowRows => _maxPreWindowRows;
|
||||
|
||||
/// <summary>
|
||||
/// The server raw cap (<c>ServerHistorian:MaxRawValuesPerRead</c>, R08:1.1): the most samples one raw read may
|
||||
/// return; 0 = none. See <see cref="MaxRawValuesPerRead"/> and <see cref="ReadRawWindowAsync"/>.
|
||||
/// </summary>
|
||||
private readonly int _maxRawValuesPerRead;
|
||||
|
||||
/// <summary>A strict gateway's row ceiling, learned from its first refusal.</summary>
|
||||
private readonly GatewayRowCeiling _ceiling;
|
||||
private readonly GatewayTagPresenceCache _tags;
|
||||
@@ -96,11 +102,19 @@ public sealed class GatewayHistorianDataSource : IHistorianDataSource, IAsyncDis
|
||||
/// The most rows before a raw window a crowding re-read makes room for (<c>ServerHistorian:MaxTieClusterOverfetch</c>,
|
||||
/// values below 1 count as 1). More ⇒ <see cref="HistoryReadLimitExceededException"/> (<c>BadTooManyOperations</c>).
|
||||
/// </param>
|
||||
/// <param name="maxRawValuesPerRead">
|
||||
/// The server raw cap (<c>ServerHistorian:MaxRawValuesPerRead</c>, R08:1.1): the most samples one
|
||||
/// <see cref="ReadRawAsync"/> may return — reported as <see cref="MaxRawValuesPerRead"/> (bounded further by a strict
|
||||
/// gateway's learned ceiling), so the server pages at it. A read asking for more (or for everything) asks the gateway
|
||||
/// for cap + 1 rows and is refused when the window holds more, never truncated. <= 0 = unbounded (the pre-#736
|
||||
/// behaviour: an uncapped read is sent as <see cref="int.MaxValue"/>).
|
||||
/// </param>
|
||||
public GatewayHistorianDataSource(IHistorianGatewayClient client, ILogger<GatewayHistorianDataSource> logger,
|
||||
int maxRawRows = TimeWeightedAggregator.DefaultMaxWindowRows, TimeProvider? timeProvider = null,
|
||||
bool atTimeFromRaw = true, int maxPreWindowRows = DefaultMaxPreWindowRows)
|
||||
bool atTimeFromRaw = true, int maxPreWindowRows = DefaultMaxPreWindowRows, int maxRawValuesPerRead = 0)
|
||||
{
|
||||
_maxPreWindowRows = Math.Max(1, maxPreWindowRows);
|
||||
_maxRawValuesPerRead = Math.Max(0, maxRawValuesPerRead);
|
||||
_atTimeFromRaw = atTimeFromRaw;
|
||||
ArgumentNullException.ThrowIfNull(client);
|
||||
ArgumentNullException.ThrowIfNull(logger);
|
||||
@@ -203,6 +217,13 @@ public sealed class GatewayHistorianDataSource : IHistorianDataSource, IAsyncDis
|
||||
/// a cancelled gateway stream evicts its pooled historian session). <c>ReturnBounds</c> is not plumbed to the
|
||||
/// data source on any backend, so bounding values are never synthesised here.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// <b>The server raw cap</b> (R08:1.1, #736). With a cap, a read asking for everything (<c>0</c>) or for more than
|
||||
/// the cap runs as a capped read of cap + 1 — one more than it may return — so an over-cap window is DETECTED and
|
||||
/// refused (<see cref="HistoryReadLimitExceededException"/>) rather than answered truncated (the server's paging
|
||||
/// reads a short answer as the last page) and never sent as <see cref="int.MaxValue"/>. The server itself never asks
|
||||
/// for more than the cap (it pages at <see cref="MaxRawValuesPerRead"/>); this bounds a caller that bypasses it.
|
||||
/// </para>
|
||||
/// </remarks>
|
||||
private async Task<List<HistorianSample>> ReadRawWindowAsync(
|
||||
string fullReference, DateTime startUtc, DateTime endUtc, uint maxValuesPerNode,
|
||||
@@ -210,30 +231,39 @@ public sealed class GatewayHistorianDataSource : IHistorianDataSource, IAsyncDis
|
||||
{
|
||||
// The gateway seam caps with an int; OPC UA hands us a uint, so clamp to int range.
|
||||
var cap = (int)Math.Min(maxValuesPerNode, int.MaxValue);
|
||||
if (cap == 0)
|
||||
var serverCap = _maxRawValuesPerRead;
|
||||
// Under the server raw cap, a read asking for everything or for more than the cap runs as a capped read of
|
||||
// cap + 1 (budgetCap); `cap` stays what the client asked for, and a refusal names the cap that applied (limit).
|
||||
var probe = serverCap > 0 && (cap == 0 || cap > serverCap);
|
||||
var budgetCap = probe ? (int)Math.Min(int.MaxValue, (long)serverCap + 1) : cap;
|
||||
var limit = probe ? serverCap : cap;
|
||||
var advice = probe
|
||||
? $"set NumValuesPerNode at or below ServerHistorian:MaxRawValuesPerRead ({serverCap}) to page"
|
||||
: cap == 0 ? "set NumValuesPerNode to page" : "lower NumValuesPerNode";
|
||||
if (budgetCap == 0)
|
||||
{
|
||||
var all = await PassAsync(int.MaxValue).ConfigureAwait(false);
|
||||
if (all.Result.Complete) return all.Result.Samples;
|
||||
// Only reachable on a strict gateway: the ceiling re-read delivered the whole ceiling without reaching
|
||||
// the window end — the window may hold more, and "all values" is never answered from a truncated read.
|
||||
throw new HistoryReadLimitExceededException(cap,
|
||||
throw new HistoryReadLimitExceededException(limit,
|
||||
$"The raw read of '{fullReference}' holds more than the HistorianGateway's row ceiling ({all.Budget}, its " +
|
||||
"Historian:ReadLimits:MaxValuesCeiling with AllowStreamingBeyondCeiling=false); set NumValuesPerNode to page, " +
|
||||
"or narrow the window.")
|
||||
{ PreWindowRows = Crowding(all.Result.PreWindowRows) };
|
||||
}
|
||||
|
||||
var asked = (int)Math.Min(int.MaxValue, (long)cap + RawAggregateReader.PreWindowAllowance);
|
||||
var asked = (int)Math.Min(int.MaxValue, (long)budgetCap + RawAggregateReader.PreWindowAllowance);
|
||||
var pass = await PassAsync(asked).ConfigureAwait(false);
|
||||
if (pass.Result.Complete) return pass.Result.Samples;
|
||||
if (pass.Result.Complete) return Bounded(pass.Result.Samples);
|
||||
|
||||
// A strict gateway's ceiling already bounded that read: a larger budget would only be refused again. The
|
||||
// refusal carries the pre-window rows it saw: the server re-reads the page that many values smaller.
|
||||
if (pass.Budget < asked)
|
||||
throw new HistoryReadLimitExceededException(cap,
|
||||
throw new HistoryReadLimitExceededException(limit,
|
||||
$"The raw read of '{fullReference}' could not be read completely within the HistorianGateway's row ceiling " +
|
||||
$"({pass.Budget}, its Historian:ReadLimits:MaxValuesCeiling with AllowStreamingBeyondCeiling=false); lower " +
|
||||
"NumValuesPerNode or narrow the window.")
|
||||
$"({pass.Budget}, its Historian:ReadLimits:MaxValuesCeiling with AllowStreamingBeyondCeiling=false); {advice}, " +
|
||||
"or narrow the window.")
|
||||
{ PreWindowRows = Crowding(pass.Result.PreWindowRows) };
|
||||
|
||||
// The margin crowded the window out: re-read with room for the pre-window rows. A read that was itself cut short saw
|
||||
@@ -245,25 +275,25 @@ public sealed class GatewayHistorianDataSource : IHistorianDataSource, IAsyncDis
|
||||
var room = Math.Min(Math.Max(1, preWindow), _maxPreWindowRows);
|
||||
for (var attempt = 0; attempt < MaxCrowdedReReads && preWindow <= _maxPreWindowRows; attempt++)
|
||||
{
|
||||
var budget = (int)Math.Min(int.MaxValue, (long)cap + room + RawAggregateReader.PreWindowAllowance);
|
||||
var budget = (int)Math.Min(int.MaxValue, (long)budgetCap + room + RawAggregateReader.PreWindowAllowance);
|
||||
// doubling can leap over the ceiling while the cluster still fits. Spend the remaining room once.
|
||||
if (_ceiling.Learned is var known and > 0 && budget > known)
|
||||
{
|
||||
var available = known - cap - RawAggregateReader.PreWindowAllowance;
|
||||
var available = known - budgetCap - RawAggregateReader.PreWindowAllowance;
|
||||
if (available <= 0) break;
|
||||
room = Math.Min(room, available);
|
||||
budget = cap + room + RawAggregateReader.PreWindowAllowance;
|
||||
budget = budgetCap + room + RawAggregateReader.PreWindowAllowance;
|
||||
}
|
||||
if (budget <= pass.Budget) break; // no more room, never retry the same full read
|
||||
pass = await PassAsync(budget).ConfigureAwait(false);
|
||||
if (pass.Result.Complete) return pass.Result.Samples;
|
||||
if (pass.Result.Complete) return Bounded(pass.Result.Samples);
|
||||
preWindow = Math.Max(preWindow, pass.Result.PreWindowRows);
|
||||
if (pass.Budget < budget) break; // bounded by a ceiling learned meanwhile
|
||||
if (room >= _maxPreWindowRows) break; // the limit's worth of room did not suffice
|
||||
room = (int)Math.Min(_maxPreWindowRows, Math.Max(preWindow, 2L * room));
|
||||
}
|
||||
|
||||
throw new HistoryReadLimitExceededException(cap,
|
||||
throw new HistoryReadLimitExceededException(limit,
|
||||
$"The raw read of '{fullReference}' could not be read completely: more than {pass.Result.PreWindowRows} rows lie in " +
|
||||
$"the {RawAggregateReader.BoundaryMargin.TotalMilliseconds} ms before the window and exhausted the row budget.")
|
||||
{ PreWindowRows = preWindow };
|
||||
@@ -271,10 +301,20 @@ public sealed class GatewayHistorianDataSource : IHistorianDataSource, IAsyncDis
|
||||
// Pre-window rows the allowance did not cover are what crowded the read; fewer are not the cause.
|
||||
static int Crowding(int preWindowRows) => preWindowRows > RawAggregateReader.PreWindowAllowance ? preWindowRows : 0;
|
||||
|
||||
// The cap + 1 probe came back with one sample too many: the window holds more than the server raw cap.
|
||||
List<HistorianSample> Bounded(List<HistorianSample> samples)
|
||||
{
|
||||
if (probe && samples.Count > serverCap)
|
||||
throw new HistoryReadLimitExceededException(serverCap,
|
||||
$"The raw read of '{fullReference}' holds more than ServerHistorian:MaxRawValuesPerRead ({serverCap}) " +
|
||||
"samples; set NumValuesPerNode at or below it to page, or narrow the window.");
|
||||
return samples;
|
||||
}
|
||||
|
||||
// One drained pass; a strict gateway's refusal of the budget is retried once at the ceiling it names.
|
||||
Task<((List<HistorianSample> Samples, int PreWindowRows, bool Complete) Result, int Budget)> PassAsync(int budget) =>
|
||||
_ceiling.ReadAsync(budget,
|
||||
b => ReadRawPassAsync(fullReference, startUtc, endUtc, cap, b, cancellationToken),
|
||||
b => ReadRawPassAsync(fullReference, startUtc, endUtc, budgetCap, b, cancellationToken),
|
||||
(r, _) => !r.Complete);
|
||||
}
|
||||
|
||||
@@ -531,13 +571,20 @@ public sealed class GatewayHistorianDataSource : IHistorianDataSource, IAsyncDis
|
||||
public bool SupportsReverseRaw => false;
|
||||
|
||||
/// <inheritdoc />
|
||||
// 0 until a strict gateway (AllowStreamingBeyondCeiling=false) has refused a budget and
|
||||
// named its ceiling (GatewayRowCeiling); then that ceiling less the
|
||||
// RawAggregateReader.PreWindowAllowance a capped read adds for AVEVA's boundary row — so a page of this
|
||||
// size asks for exactly the ceiling. Back to 0 when a re-probe finds the gateway streaming again.
|
||||
public int MaxRawValuesPerRead => _ceiling.Learned is var c and > 0
|
||||
? Math.Max(1, c - RawAggregateReader.PreWindowAllowance)
|
||||
: 0;
|
||||
// The server raw cap (ServerHistorian:MaxRawValuesPerRead; 0 = none), bounded further by a strict gateway's
|
||||
// (AllowStreamingBeyondCeiling=false) learned ceiling once a refusal has named it (GatewayRowCeiling) — that
|
||||
// ceiling less the RawAggregateReader.PreWindowAllowance a capped read adds for AVEVA's boundary row, so a page of
|
||||
// this size asks for exactly the ceiling. The learned part is forgotten when a re-probe finds the gateway streaming
|
||||
// again; the cap stays. 0 only with no cap and no learned ceiling.
|
||||
public int MaxRawValuesPerRead
|
||||
{
|
||||
get
|
||||
{
|
||||
var learned = _ceiling.Learned is var c and > 0 ? Math.Max(1, c - RawAggregateReader.PreWindowAllowance) : 0;
|
||||
var cap = _maxRawValuesPerRead;
|
||||
return cap > 0 && learned > 0 ? Math.Min(cap, learned) : cap > 0 ? cap : learned;
|
||||
}
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
// false: the gateway's ReadEvents streams ascending only. The server never sends it a
|
||||
|
||||
+3
-1
@@ -44,7 +44,9 @@ public static class GatewayHistorian
|
||||
// AtTime from raw reads + the shared evaluator; false = AVEVA's own interpolation (kill switch).
|
||||
atTimeFromRaw: options.GatewayAtTimeFromRaw,
|
||||
// A crowding re-read never makes room for more pre-window rows than the tie-cluster limit.
|
||||
maxPreWindowRows: options.MaxTieClusterOverfetch);
|
||||
maxPreWindowRows: options.MaxTieClusterOverfetch,
|
||||
// The server raw cap (R08:1.1): the page limit the server reads at, and the bound on every raw read.
|
||||
maxRawValuesPerRead: options.EffectiveMaxRawValuesPerRead);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
|
||||
+34
-4
@@ -66,6 +66,7 @@ public sealed class QuestDbHistorianDataSource : IHistorianDataSource
|
||||
private readonly TimeProvider _time;
|
||||
private readonly HistorianHealthCounters _health = new();
|
||||
private readonly int _maxTimeWeightedRawRows;
|
||||
private readonly int _maxRawValuesPerRead;
|
||||
|
||||
/// <summary>Creates the data source over the provider's shared connection, bootstrapper and tag catalog.</summary>
|
||||
/// <param name="conn">Connection helper.</param>
|
||||
@@ -74,11 +75,19 @@ public sealed class QuestDbHistorianDataSource : IHistorianDataSource
|
||||
/// <param name="log">Optional logger.</param>
|
||||
/// <param name="timeProvider">Clock for "now" (AtTime beyond the last sample, server timestamps); system by default.</param>
|
||||
/// <param name="maxTimeWeightedRawRows">Raw in-window row cap of one time-weighted read (<= 0 = unbounded).</param>
|
||||
/// <param name="maxRawValuesPerRead">
|
||||
/// The server raw cap (<c>ServerHistorian:MaxRawValuesPerRead</c>, R08:1.1): the most samples one
|
||||
/// <see cref="ReadRawAsync"/> may return — reported as <see cref="MaxRawValuesPerRead"/>, so the server pages at it.
|
||||
/// A read asking for more (or for everything) is refused when the window holds more, never truncated.
|
||||
/// <= 0 = unbounded (the pre-#736 behaviour).
|
||||
/// </param>
|
||||
internal QuestDbHistorianDataSource(
|
||||
QuestDbConnection conn, QuestDbSchemaBootstrapper bootstrap, QuestDbTagCatalog catalog, ILogger? log = null,
|
||||
TimeProvider? timeProvider = null, int maxTimeWeightedRawRows = TimeWeightedAggregator.DefaultMaxWindowRows)
|
||||
TimeProvider? timeProvider = null, int maxTimeWeightedRawRows = TimeWeightedAggregator.DefaultMaxWindowRows,
|
||||
int maxRawValuesPerRead = 0)
|
||||
{
|
||||
_maxTimeWeightedRawRows = maxTimeWeightedRawRows;
|
||||
_maxRawValuesPerRead = Math.Max(0, maxRawValuesPerRead);
|
||||
_conn = conn ?? throw new ArgumentNullException(nameof(conn));
|
||||
_bootstrap = bootstrap ?? throw new ArgumentNullException(nameof(bootstrap));
|
||||
_catalog = catalog ?? throw new ArgumentNullException(nameof(catalog));
|
||||
@@ -93,12 +102,21 @@ public sealed class QuestDbHistorianDataSource : IHistorianDataSource
|
||||
// (int.MaxValue); larger values clamp. At most top samples, ContinuationPoint always null: the node
|
||||
// manager pages by re-reading from the last returned timestamp inclusive, which the (ts, tag) dedup
|
||||
// key makes exact.
|
||||
// The server raw cap (R08:1.1, #736): with a cap, a read asking for everything or for more than the cap reads
|
||||
// cap + 1 rows — one more than it may return — so an over-cap window is DETECTED and refused
|
||||
// (HistoryReadLimitExceededException ⇒ BadTooManyOperations) rather than answered truncated: the server's paging
|
||||
// reads a short answer as the last page, so a silent LIMIT would lose data. The server itself never asks for more
|
||||
// than the cap (it pages at MaxRawValuesPerRead); this bounds a caller that bypasses it.
|
||||
/// <inheritdoc />
|
||||
public async Task<HistoryReadResult> ReadRawAsync(
|
||||
string fullReference, DateTime startUtc, DateTime endUtc, uint maxValuesPerNode, CancellationToken cancellationToken)
|
||||
{
|
||||
ArgumentNullException.ThrowIfNull(fullReference);
|
||||
var top = maxValuesPerNode == 0 ? int.MaxValue : (int)Math.Min(maxValuesPerNode, int.MaxValue);
|
||||
var cap = _maxRawValuesPerRead;
|
||||
var probe = cap > 0 && (maxValuesPerNode == 0 || maxValuesPerNode > (uint)cap);
|
||||
var top = probe
|
||||
? (int)Math.Min(int.MaxValue, (long)cap + 1)
|
||||
: maxValuesPerNode == 0 ? int.MaxValue : (int)Math.Min(maxValuesPerNode, int.MaxValue);
|
||||
try
|
||||
{
|
||||
var samples = new List<DataValueSnapshot>();
|
||||
@@ -129,9 +147,19 @@ public sealed class QuestDbHistorianDataSource : IHistorianDataSource
|
||||
}
|
||||
}
|
||||
|
||||
if (probe && samples.Count > cap)
|
||||
throw new HistoryReadLimitExceededException(cap,
|
||||
$"The raw read of '{fullReference}' holds more than ServerHistorian:MaxRawValuesPerRead ({cap}) samples; " +
|
||||
"set NumValuesPerNode at or below it to page, or narrow the window.");
|
||||
|
||||
RecordSuccess();
|
||||
return new HistoryReadResult(samples, ContinuationPoint: null);
|
||||
}
|
||||
catch (HistoryReadLimitExceededException)
|
||||
{
|
||||
// A client-request limit (the server raw cap), not a backend fault: not counted as a failure.
|
||||
throw;
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
RecordFailure(ex);
|
||||
@@ -360,9 +388,11 @@ public sealed class QuestDbHistorianDataSource : IHistorianDataSource
|
||||
/// <inheritdoc />
|
||||
public bool SupportsReverseRaw => true;
|
||||
|
||||
// 0: a capped raw read is one bounded statement - no backend row ceiling.
|
||||
// The server raw cap (ServerHistorian:MaxRawValuesPerRead; 0 = none): the server pages every raw read at it, so a
|
||||
// client's NumValuesPerNode = 0 is served as pages of at most this many values. QuestDB itself has no row ceiling -
|
||||
// a capped raw read is one bounded statement.
|
||||
/// <inheritdoc />
|
||||
public int MaxRawValuesPerRead => 0;
|
||||
public int MaxRawValuesPerRead => _maxRawValuesPerRead;
|
||||
|
||||
// Reverse events reads are served natively (ORDER BY ... DESC).
|
||||
/// <inheritdoc />
|
||||
|
||||
@@ -35,14 +35,17 @@ public sealed class QuestDbHistorianProvider : IHistorianBackendProvider, IAsync
|
||||
/// <summary>Creates the provider over the <c>ServerHistorian:QuestDb</c> options (validated elsewhere).</summary>
|
||||
/// <param name="options">The <c>ServerHistorian:QuestDb</c> options.</param>
|
||||
/// <param name="maxTimeWeightedRawRows">The shared <c>ServerHistorian:MaxTimeWeightedRawRows</c> cap (<= 0 = unbounded).</param>
|
||||
/// <param name="maxRawValuesPerRead">The shared <c>ServerHistorian:MaxRawValuesPerRead</c> raw cap (<= 0 = unbounded; R08:1.1).</param>
|
||||
public QuestDbHistorianProvider(QuestDbHistorianOptions options,
|
||||
int maxTimeWeightedRawRows = TimeWeightedAggregator.DefaultMaxWindowRows)
|
||||
int maxTimeWeightedRawRows = TimeWeightedAggregator.DefaultMaxWindowRows, int maxRawValuesPerRead = 0)
|
||||
{
|
||||
_options = options ?? throw new ArgumentNullException(nameof(options));
|
||||
_maxTimeWeightedRawRows = maxTimeWeightedRawRows;
|
||||
_maxRawValuesPerRead = maxRawValuesPerRead;
|
||||
}
|
||||
|
||||
private readonly int _maxTimeWeightedRawRows;
|
||||
private readonly int _maxRawValuesPerRead;
|
||||
|
||||
/// <inheritdoc />
|
||||
public string Name => "QuestDb";
|
||||
@@ -75,7 +78,8 @@ public sealed class QuestDbHistorianProvider : IHistorianBackendProvider, IAsync
|
||||
{
|
||||
var s = Get(sp);
|
||||
return new QuestDbHistorianDataSource(s.Conn, s.Bootstrap, s.Catalog,
|
||||
Loggers(sp).CreateLogger<QuestDbHistorianDataSource>(), maxTimeWeightedRawRows: _maxTimeWeightedRawRows);
|
||||
Loggers(sp).CreateLogger<QuestDbHistorianDataSource>(), maxTimeWeightedRawRows: _maxTimeWeightedRawRows,
|
||||
maxRawValuesPerRead: _maxRawValuesPerRead);
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
|
||||
+36
-4
@@ -61,6 +61,7 @@ public sealed class SqlServerHistorianDataSource : IHistorianDataSource
|
||||
|
||||
private readonly HistorianHealthCounters _health = new();
|
||||
private readonly int _maxTimeWeightedRawRows;
|
||||
private readonly int _maxRawValuesPerRead;
|
||||
|
||||
/// <summary>Creates the data source over the provider's shared connection, bootstrapper and tag catalog.</summary>
|
||||
/// <param name="conn">Connection helper.</param>
|
||||
@@ -69,11 +70,19 @@ public sealed class SqlServerHistorianDataSource : IHistorianDataSource
|
||||
/// <param name="log">Optional logger.</param>
|
||||
/// <param name="timeProvider">Clock for "now" (AtTime beyond the last sample, server timestamps); system by default.</param>
|
||||
/// <param name="maxTimeWeightedRawRows">Raw in-window row cap of one time-weighted read (<= 0 = unbounded).</param>
|
||||
/// <param name="maxRawValuesPerRead">
|
||||
/// The server raw cap (<c>ServerHistorian:MaxRawValuesPerRead</c>, R08:1.1): the most samples one
|
||||
/// <see cref="ReadRawAsync"/> may return — reported as <see cref="MaxRawValuesPerRead"/>, so the server pages at it.
|
||||
/// A read asking for more (or for everything) is refused when the window holds more, never truncated.
|
||||
/// <= 0 = unbounded (the pre-#736 behaviour).
|
||||
/// </param>
|
||||
internal SqlServerHistorianDataSource(
|
||||
SqlHistorianConnection conn, SqlServerSchemaBootstrapper bootstrap, SqlServerTagCatalog catalog, ILogger? log = null,
|
||||
TimeProvider? timeProvider = null, int maxTimeWeightedRawRows = TimeWeightedAggregator.DefaultMaxWindowRows)
|
||||
TimeProvider? timeProvider = null, int maxTimeWeightedRawRows = TimeWeightedAggregator.DefaultMaxWindowRows,
|
||||
int maxRawValuesPerRead = 0)
|
||||
{
|
||||
_maxTimeWeightedRawRows = maxTimeWeightedRawRows;
|
||||
_maxRawValuesPerRead = Math.Max(0, maxRawValuesPerRead);
|
||||
_conn = conn ?? throw new ArgumentNullException(nameof(conn));
|
||||
_bootstrap = bootstrap ?? throw new ArgumentNullException(nameof(bootstrap));
|
||||
_catalog = catalog ?? throw new ArgumentNullException(nameof(catalog));
|
||||
@@ -90,13 +99,22 @@ public sealed class SqlServerHistorianDataSource : IHistorianDataSource
|
||||
// <c>0</c> is the node manager's "unbounded" sentinel; values above <see cref="int.MaxValue"/> clamp.
|
||||
// The node manager pages by re-reading from the last returned timestamp inclusive and trimming it; the
|
||||
// <c>(TagId, SourceTimeUtc)</c> primary key rules out tie clusters, so that is exact.
|
||||
// The server raw cap (R08:1.1, #736): with a cap, a read asking for everything or for more than the cap reads
|
||||
// cap + 1 rows — one more than it may return — so an over-cap window is DETECTED and refused
|
||||
// (HistoryReadLimitExceededException ⇒ BadTooManyOperations) rather than answered truncated: the server's paging
|
||||
// reads a short answer as the last page, so a silent TOP would lose data. The server itself never asks for more than
|
||||
// the cap (it pages at MaxRawValuesPerRead); this bounds a caller that bypasses it.
|
||||
// </remarks>
|
||||
/// <inheritdoc />
|
||||
public async Task<HistoryReadResult> ReadRawAsync(
|
||||
string fullReference, DateTime startUtc, DateTime endUtc, uint maxValuesPerNode, CancellationToken cancellationToken)
|
||||
{
|
||||
ArgumentNullException.ThrowIfNull(fullReference);
|
||||
var top = maxValuesPerNode == 0 ? int.MaxValue : (int)Math.Min(maxValuesPerNode, int.MaxValue);
|
||||
var cap = _maxRawValuesPerRead;
|
||||
var probe = cap > 0 && (maxValuesPerNode == 0 || maxValuesPerNode > (uint)cap);
|
||||
var top = probe
|
||||
? (int)Math.Min(int.MaxValue, (long)cap + 1)
|
||||
: maxValuesPerNode == 0 ? int.MaxValue : (int)Math.Min(maxValuesPerNode, int.MaxValue);
|
||||
try
|
||||
{
|
||||
var tagId = await ResolveAsync(fullReference, cancellationToken).ConfigureAwait(false);
|
||||
@@ -126,9 +144,19 @@ public sealed class SqlServerHistorianDataSource : IHistorianDataSource
|
||||
}
|
||||
}
|
||||
|
||||
if (probe && samples.Count > cap)
|
||||
throw new HistoryReadLimitExceededException(cap,
|
||||
$"The raw read of '{fullReference}' holds more than ServerHistorian:MaxRawValuesPerRead ({cap}) samples; " +
|
||||
"set NumValuesPerNode at or below it to page, or narrow the window.");
|
||||
|
||||
RecordSuccess();
|
||||
return new HistoryReadResult(samples, ContinuationPoint: null);
|
||||
}
|
||||
catch (HistoryReadLimitExceededException)
|
||||
{
|
||||
// A client-request limit (the server raw cap), not a backend fault: not counted as a failure.
|
||||
throw;
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
RecordFailure(ex);
|
||||
@@ -319,9 +347,13 @@ public sealed class SqlServerHistorianDataSource : IHistorianDataSource
|
||||
/// <inheritdoc />
|
||||
public bool SupportsReverseRaw => true;
|
||||
|
||||
// <remarks><c>0</c>: a capped raw read is one bounded statement — no backend row ceiling.</remarks>
|
||||
// <remarks>
|
||||
// The server raw cap (ServerHistorian:MaxRawValuesPerRead; 0 = none): the server pages every raw read at it, so a
|
||||
// client's NumValuesPerNode = 0 is served as pages of at most this many values. SQL Server itself has no row
|
||||
// ceiling — a capped raw read is one bounded statement.
|
||||
// </remarks>
|
||||
/// <inheritdoc />
|
||||
public int MaxRawValuesPerRead => 0;
|
||||
public int MaxRawValuesPerRead => _maxRawValuesPerRead;
|
||||
|
||||
// <remarks>Reverse events reads are served natively (<c>ORDER BY … DESC</c>).</remarks>
|
||||
/// <inheritdoc />
|
||||
|
||||
+6
-2
@@ -31,14 +31,17 @@ public sealed class SqlServerHistorianProvider : IHistorianBackendProvider
|
||||
/// <summary>Creates the provider over the <c>ServerHistorian:SqlServer</c> options (validated elsewhere).</summary>
|
||||
/// <param name="options">The <c>ServerHistorian:SqlServer</c> options.</param>
|
||||
/// <param name="maxTimeWeightedRawRows">The shared <c>ServerHistorian:MaxTimeWeightedRawRows</c> cap (<= 0 = unbounded).</param>
|
||||
/// <param name="maxRawValuesPerRead">The shared <c>ServerHistorian:MaxRawValuesPerRead</c> raw cap (<= 0 = unbounded; R08:1.1).</param>
|
||||
public SqlServerHistorianProvider(SqlServerHistorianOptions options,
|
||||
int maxTimeWeightedRawRows = TimeWeightedAggregator.DefaultMaxWindowRows)
|
||||
int maxTimeWeightedRawRows = TimeWeightedAggregator.DefaultMaxWindowRows, int maxRawValuesPerRead = 0)
|
||||
{
|
||||
_options = options ?? throw new ArgumentNullException(nameof(options));
|
||||
_maxTimeWeightedRawRows = maxTimeWeightedRawRows;
|
||||
_maxRawValuesPerRead = maxRawValuesPerRead;
|
||||
}
|
||||
|
||||
private readonly int _maxTimeWeightedRawRows;
|
||||
private readonly int _maxRawValuesPerRead;
|
||||
|
||||
/// <inheritdoc />
|
||||
public string Name => "SqlServer";
|
||||
@@ -69,7 +72,8 @@ public sealed class SqlServerHistorianProvider : IHistorianBackendProvider
|
||||
{
|
||||
var s = Get(sp);
|
||||
return new SqlServerHistorianDataSource(s.Conn, s.Bootstrap, s.Catalog,
|
||||
Loggers(sp).CreateLogger<SqlServerHistorianDataSource>(), maxTimeWeightedRawRows: _maxTimeWeightedRawRows);
|
||||
Loggers(sp).CreateLogger<SqlServerHistorianDataSource>(), maxTimeWeightedRawRows: _maxTimeWeightedRawRows,
|
||||
maxRawValuesPerRead: _maxRawValuesPerRead);
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
|
||||
+4
@@ -26,6 +26,10 @@
|
||||
provider's DbProviderFactory (NpgsqlFactory / OracleClientFactory); both packages are fully
|
||||
managed ADO.NET drivers, so adding them costs no native client install anywhere. -->
|
||||
<PackageReference Include="Microsoft.Data.SqlClient" />
|
||||
<!-- Surgical transitive pin — see the System.Security.Cryptography.Pkcs block in
|
||||
Directory.Packages.props. SqlClient 6.1.1 pulls a vulnerable Pkcs 9.0.4; this is the
|
||||
second place the SqlClient chain enters the repo (Core.Configuration is the first). -->
|
||||
<PackageReference Include="System.Security.Cryptography.Pkcs" />
|
||||
<PackageReference Include="Npgsql" />
|
||||
<PackageReference Include="Oracle.ManagedDataAccess.Core" />
|
||||
</ItemGroup>
|
||||
|
||||
@@ -1,4 +1,6 @@
|
||||
using Akka.Actor;
|
||||
using Microsoft.Extensions.Logging;
|
||||
using Microsoft.Extensions.Logging.Abstractions;
|
||||
using Microsoft.Extensions.Options;
|
||||
using ZB.MOM.WW.OtOpcUa.Cluster;
|
||||
using ZB.MOM.WW.OtOpcUa.Commons.Interfaces;
|
||||
@@ -13,7 +15,9 @@ namespace ZB.MOM.WW.OtOpcUa.AdminUI.Clients;
|
||||
/// Sends <see cref="GetDiagnostics"/>; expects a <see cref="NodeDiagnosticsSnapshot"/> reply.
|
||||
///
|
||||
/// On timeout or any other failure (peer down, GetDiagnostics handler missing) returns an
|
||||
/// empty snapshot so the UI degrades to "no data" instead of throwing.
|
||||
/// empty snapshot so the UI degrades to "no data" instead of throwing. The failure is logged at
|
||||
/// Warning, since the snapshot shape cannot carry it: an empty snapshot reads the same as a node with
|
||||
/// no drivers. Consumed by the <c>/fleet/diagnostics</c> page.
|
||||
/// </summary>
|
||||
public sealed class FleetDiagnosticsClient : IFleetDiagnosticsClient
|
||||
{
|
||||
@@ -21,29 +25,38 @@ public sealed class FleetDiagnosticsClient : IFleetDiagnosticsClient
|
||||
|
||||
private readonly ActorSystem _system;
|
||||
private readonly string _systemName;
|
||||
private readonly ILogger<FleetDiagnosticsClient> _log;
|
||||
|
||||
/// <summary>Initializes a new FleetDiagnosticsClient with the given actor system and cluster options.</summary>
|
||||
/// <param name="system">The Akka actor system.</param>
|
||||
/// <param name="options">Cluster configuration options.</param>
|
||||
public FleetDiagnosticsClient(ActorSystem system, IOptions<AkkaClusterOptions> options)
|
||||
/// <param name="log">Logger for the degraded-to-empty path; defaults to a no-op logger.</param>
|
||||
public FleetDiagnosticsClient(
|
||||
ActorSystem system, IOptions<AkkaClusterOptions> options, ILogger<FleetDiagnosticsClient>? log = null)
|
||||
{
|
||||
_system = system;
|
||||
_systemName = options.Value.SystemName;
|
||||
_log = log ?? NullLogger<FleetDiagnosticsClient>.Instance;
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
public async Task<NodeDiagnosticsSnapshot> GetDiagnosticsAsync(NodeId nodeId, CancellationToken ct)
|
||||
{
|
||||
var selection = _system.ActorSelection($"akka.tcp://{_systemName}@{nodeId.Value}/user/driver-host");
|
||||
try
|
||||
{
|
||||
// Inside the try: a malformed node value makes ActorSelection throw, and that must degrade to
|
||||
// "unavailable" like a dead node does, not surface through the page's error boundary.
|
||||
var selection = _system.ActorSelection($"akka.tcp://{_systemName}@{nodeId.Value}/user/driver-host");
|
||||
using var linked = CancellationTokenSource.CreateLinkedTokenSource(ct);
|
||||
linked.CancelAfter(AskTimeout);
|
||||
return await selection.Ask<NodeDiagnosticsSnapshot>(
|
||||
new GetDiagnostics(CorrelationId.NewId()), AskTimeout, linked.Token);
|
||||
}
|
||||
catch (Exception)
|
||||
catch (Exception ex) when (!ct.IsCancellationRequested)
|
||||
{
|
||||
_log.LogWarning(ex,
|
||||
"Fleet diagnostics for node {NodeId} unavailable (no answer within {Timeout}s); returning an empty snapshot",
|
||||
nodeId.Value, AskTimeout.TotalSeconds);
|
||||
return new NodeDiagnosticsSnapshot(
|
||||
nodeId,
|
||||
CurrentRevision: null,
|
||||
|
||||
@@ -0,0 +1,238 @@
|
||||
@page "/fleet/diagnostics"
|
||||
@* Per-node driver diagnostics, fetched on demand from the selected driver node's DriverHostActor over
|
||||
Akka (IFleetDiagnosticsClient → GetDiagnostics → NodeDiagnosticsSnapshot). The node answers from
|
||||
its live child set + each child's last-published health; the "running from cache" flag is the one
|
||||
fact /hosts cannot show (a node booted from its artifact cache looks healthy but is frozen).
|
||||
Reach it as /fleet/diagnostics?node=<host:port> (the NodeId shown on /fleet and /hosts), or pick
|
||||
a driver-role member from the selector. *@
|
||||
@attribute [Authorize(Policy = AdminUiPolicies.AuthenticatedRead)]
|
||||
@rendermode RenderMode.InteractiveServer
|
||||
@using ZB.MOM.WW.OtOpcUa.Cluster
|
||||
@using ZB.MOM.WW.OtOpcUa.Commons.Interfaces
|
||||
@using ZB.MOM.WW.OtOpcUa.Commons.Types
|
||||
@inject IClusterRoleInfo Cluster
|
||||
@inject IFleetDiagnosticsClient Diagnostics
|
||||
@inject NavigationManager Nav
|
||||
@implements IDisposable
|
||||
|
||||
<PageErrorBoundary>
|
||||
<div class="d-flex justify-content-between align-items-center mb-3">
|
||||
<h4 class="mb-0">Node diagnostics</h4>
|
||||
<a class="btn btn-sm btn-outline-secondary" href="/fleet">Back to fleet status</a>
|
||||
</div>
|
||||
|
||||
<div class="d-flex align-items-center mb-3 gap-2 flex-wrap">
|
||||
<label class="small text-muted mb-0" for="diag-node">Node</label>
|
||||
<select id="diag-node" class="form-select form-select-sm" style="width:auto"
|
||||
value="@_selectedNode" @onchange="OnNodeSelected">
|
||||
<option value="">— select a driver node —</option>
|
||||
@foreach (var member in _members)
|
||||
{
|
||||
<option value="@member">@member</option>
|
||||
}
|
||||
@if (!string.IsNullOrEmpty(_selectedNode) && !_members.Contains(_selectedNode))
|
||||
{
|
||||
<option value="@_selectedNode">@_selectedNode (not an Up member)</option>
|
||||
}
|
||||
</select>
|
||||
<input type="text" class="form-control form-control-sm" style="width:220px"
|
||||
placeholder="or type host:port…" @bind="_typedNode" @bind:event="oninput"
|
||||
@onkeydown="OnTypedKeyDown" />
|
||||
<button class="btn btn-sm btn-outline-primary" @onclick="UseTypedNodeAsync"
|
||||
disabled="@(string.IsNullOrWhiteSpace(_typedNode))">Go</button>
|
||||
<button class="btn btn-sm btn-outline-primary" @onclick="RefreshAsync"
|
||||
disabled="@(_loading || string.IsNullOrEmpty(_selectedNode))">
|
||||
@if (_loading) { <span class="spinner-border spinner-border-sm me-1" /> }
|
||||
Refresh
|
||||
</button>
|
||||
<span class="text-muted small">
|
||||
Last fetched: @(_fetchedUtc?.ToString("HH:mm:ss 'UTC'") ?? "—")
|
||||
</span>
|
||||
</div>
|
||||
|
||||
@if (string.IsNullOrEmpty(_selectedNode))
|
||||
{
|
||||
<section class="panel notice rise" style="animation-delay:.02s">
|
||||
Pick a driver-role node to fetch its driver diagnostics. The node answers from its own
|
||||
DriverHostActor, so this works for any node reachable over Akka remoting from this admin node.
|
||||
</section>
|
||||
}
|
||||
else if (_snapshot is null)
|
||||
{
|
||||
<p>@(_loading ? "Fetching…" : "No snapshot yet.")</p>
|
||||
}
|
||||
else
|
||||
{
|
||||
<section class="agg-grid rise" style="animation-delay:.02s">
|
||||
<div class="agg-card">
|
||||
<div class="agg-label">Node</div>
|
||||
<div class="agg-value mono">@_snapshot.NodeId.Value</div>
|
||||
</div>
|
||||
<div class="agg-card">
|
||||
<div class="agg-label">Revision</div>
|
||||
<div class="agg-value mono" title="@(_snapshot.CurrentRevision?.Value ?? "")">
|
||||
@(_snapshot.CurrentRevision is { } rev ? DisplayText.Abbreviate(rev.Value, 12) : "—")
|
||||
</div>
|
||||
</div>
|
||||
<div class="agg-card @(_snapshot.RunningFromCache ? "caution" : "")">
|
||||
<div class="agg-label">Config source</div>
|
||||
<div class="agg-value">@(_snapshot.RunningFromCache ? "cache (frozen)" : "live")</div>
|
||||
</div>
|
||||
<div class="agg-card">
|
||||
<div class="agg-label">Drivers</div>
|
||||
<div class="agg-value numeric">@_snapshot.Drivers.Count</div>
|
||||
</div>
|
||||
<div class="agg-card alert">
|
||||
<div class="agg-label">Faulted devices</div>
|
||||
<div class="agg-value numeric">@_snapshot.Drivers.Sum(d => d.FaultedDevices)</div>
|
||||
</div>
|
||||
</section>
|
||||
|
||||
@if (_snapshot.RunningFromCache)
|
||||
{
|
||||
<section class="panel notice rise" style="animation-delay:.05s">
|
||||
This node booted its configuration from its local artifact cache because central was unreachable.
|
||||
It serves its last-known-good address space, but no deployment can reach it until central is back.
|
||||
</section>
|
||||
}
|
||||
|
||||
<section class="panel rise" style="animation-delay:.08s">
|
||||
<div class="panel-head">
|
||||
Drivers
|
||||
<span class="text-muted small ms-2">as of @_snapshot.AsOfUtc.ToString("u")</span>
|
||||
</div>
|
||||
@if (_snapshot.Drivers.Count == 0)
|
||||
{
|
||||
<div class="p-3 text-muted">
|
||||
Empty snapshot: the node has no driver children — or it did not answer within the client's
|
||||
3 s budget (an unreachable node degrades to an empty snapshot; see the AdminUI log for the
|
||||
FleetDiagnosticsClient warning).
|
||||
</div>
|
||||
}
|
||||
else
|
||||
{
|
||||
<div class="table-wrap">
|
||||
<table class="data-table">
|
||||
<thead>
|
||||
<tr>
|
||||
<th>Driver instance</th>
|
||||
<th>Row id</th>
|
||||
<th>State</th>
|
||||
<th class="numeric">Connected devices</th>
|
||||
<th class="numeric">Faulted devices</th>
|
||||
<th title="When the driver child last published a changed health snapshot (its spawn time until the first)">Last health publish</th>
|
||||
</tr>
|
||||
</thead>
|
||||
<tbody>
|
||||
@foreach (var d in _snapshot.Drivers.OrderBy(d => d.Name, StringComparer.OrdinalIgnoreCase))
|
||||
{
|
||||
<tr>
|
||||
<td>@d.Name</td>
|
||||
<td><span class="mono" title="@d.DriverInstanceId">@(d.DriverInstanceId == Guid.Empty ? "—" : DisplayText.Abbreviate(d.DriverInstanceId.ToString(), 13))</span></td>
|
||||
<td><span class="chip @StateChipClass(d.State)">@d.State</span></td>
|
||||
<td class="numeric">@d.ConnectedDevices</td>
|
||||
<td class="numeric">@d.FaultedDevices</td>
|
||||
<td>@d.LastChangeUtc.ToString("u")</td>
|
||||
</tr>
|
||||
}
|
||||
</tbody>
|
||||
</table>
|
||||
</div>
|
||||
}
|
||||
</section>
|
||||
}
|
||||
</PageErrorBoundary>
|
||||
|
||||
@code {
|
||||
[SupplyParameterFromQuery(Name = "node")]
|
||||
public string? Node { get; set; }
|
||||
|
||||
private IReadOnlyList<string> _members = Array.Empty<string>();
|
||||
private string _selectedNode = "";
|
||||
private string _typedNode = "";
|
||||
private NodeDiagnosticsSnapshot? _snapshot;
|
||||
private bool _loading;
|
||||
private DateTime? _fetchedUtc;
|
||||
|
||||
// Page-lifetime cancellation: a fetch in flight when the circuit goes away is abandoned.
|
||||
private readonly CancellationTokenSource _cts = new();
|
||||
private volatile bool _disposed;
|
||||
|
||||
protected override async Task OnParametersSetAsync()
|
||||
{
|
||||
_members = Cluster.MembersWithRole(RoleParser.Driver)
|
||||
.Select(n => n.Value)
|
||||
.OrderBy(s => s, StringComparer.OrdinalIgnoreCase)
|
||||
.ToList();
|
||||
var requested = Node?.Trim() ?? "";
|
||||
if (!string.Equals(requested, _selectedNode, StringComparison.Ordinal))
|
||||
{
|
||||
_selectedNode = requested;
|
||||
_snapshot = null;
|
||||
if (!string.IsNullOrEmpty(_selectedNode)) await LoadAsync();
|
||||
}
|
||||
}
|
||||
|
||||
private Task OnNodeSelected(ChangeEventArgs e)
|
||||
{
|
||||
var value = e.Value?.ToString() ?? "";
|
||||
Navigate(value);
|
||||
return Task.CompletedTask;
|
||||
}
|
||||
|
||||
private Task UseTypedNodeAsync()
|
||||
{
|
||||
Navigate(_typedNode.Trim());
|
||||
return Task.CompletedTask;
|
||||
}
|
||||
|
||||
private Task OnTypedKeyDown(KeyboardEventArgs e)
|
||||
{
|
||||
if (e.Key == "Enter") Navigate(_typedNode.Trim());
|
||||
return Task.CompletedTask;
|
||||
}
|
||||
|
||||
// The node id lives in the URL so a diagnostics view is linkable from /fleet and survives a reload.
|
||||
private void Navigate(string node) =>
|
||||
Nav.NavigateTo(string.IsNullOrEmpty(node)
|
||||
? "/fleet/diagnostics"
|
||||
: "/fleet/diagnostics?node=" + Uri.EscapeDataString(node));
|
||||
|
||||
private async Task RefreshAsync() => await LoadAsync();
|
||||
|
||||
private async Task LoadAsync()
|
||||
{
|
||||
if (_loading || string.IsNullOrEmpty(_selectedNode)) return;
|
||||
_loading = true;
|
||||
try
|
||||
{
|
||||
// The client is fail-safe by contract: a node that does not answer yields an empty snapshot.
|
||||
_snapshot = await Diagnostics.GetDiagnosticsAsync(NodeId.Parse(_selectedNode), _cts.Token);
|
||||
_fetchedUtc = DateTime.UtcNow;
|
||||
}
|
||||
catch (Exception ex) when (ex is OperationCanceledException or ObjectDisposedException)
|
||||
{
|
||||
// Circuit gone mid-fetch — a clean exit, not a fault.
|
||||
}
|
||||
finally
|
||||
{
|
||||
_loading = false;
|
||||
if (!_disposed) StateHasChanged();
|
||||
}
|
||||
}
|
||||
|
||||
private static string StateChipClass(string state) => state switch
|
||||
{
|
||||
"Healthy" => "chip-ok",
|
||||
"Degraded" or "Connecting" or "Reconnecting" => "chip-caution",
|
||||
"Faulted" => "chip-alert",
|
||||
_ => "chip-idle",
|
||||
};
|
||||
|
||||
public void Dispose()
|
||||
{
|
||||
_disposed = true;
|
||||
_cts.Cancel();
|
||||
_cts.Dispose();
|
||||
}
|
||||
}
|
||||
@@ -129,6 +129,7 @@ public sealed class TelemetryDialSupervisor : ReceiveActor, IWithTimers
|
||||
Receive<TelemetryReceived>(HandleTelemetryReceived);
|
||||
Receive<StreamStopped>(HandleStreamStopped);
|
||||
Receive<Reconnect>(HandleReconnect);
|
||||
Receive<DialDeadline>(HandleDialDeadline);
|
||||
|
||||
// A faulted node-source task pipes here. Log and wait for the next periodic refresh — a stale
|
||||
// node set is far better than crashing the supervisor and dropping every live dialer.
|
||||
@@ -251,6 +252,9 @@ public sealed class TelemetryDialSupervisor : ReceiveActor, IWithTimers
|
||||
return;
|
||||
}
|
||||
|
||||
// The stream is over; a still-armed establishment deadline for it must not fire into the reconnect.
|
||||
Timers.Cancel(DeadlineTimerKey(msg.NodeId));
|
||||
|
||||
if (dialer.Connected)
|
||||
{
|
||||
dialer.Connected = false;
|
||||
@@ -294,6 +298,34 @@ public sealed class TelemetryDialSupervisor : ReceiveActor, IWithTimers
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// <c>TelemetryDial:CallTimeoutSeconds</c>: a dial that has delivered no event by the deadline is cut and
|
||||
/// treated as a transport failure (reconnect with a failure streak). <c>Connected</c> flips on the first
|
||||
/// routed event, on this thread, so a dial that connected in time is left alone — the deadline bounds
|
||||
/// ESTABLISHMENT only. A live node answers a fresh subscribe at once (the node-local hub replays its
|
||||
/// health/resilience snapshots), so what this catches is a dial that never connects: a black-holed host,
|
||||
/// where the socket connect itself has no timeout and the stream would otherwise hang forever without a
|
||||
/// reconnect. An established stream is never bounded here — the wire has no heartbeat, keepalive pings own
|
||||
/// its liveness, and an idle cut would churn every quiet node.
|
||||
/// </summary>
|
||||
private void HandleDialDeadline(DialDeadline msg)
|
||||
{
|
||||
if (!_dialers.TryGetValue(msg.NodeId, out var dialer) || msg.Generation != dialer.Generation || dialer.Connected)
|
||||
{
|
||||
return;
|
||||
}
|
||||
|
||||
_log.Warning(
|
||||
"Telemetry dial to node {NodeId} ({Endpoint}) delivered nothing within {Deadline}s; cancelling it and re-dialing",
|
||||
msg.NodeId, dialer.Target.Endpoint, DialDeadlineFor().TotalSeconds);
|
||||
dialer.Cancel();
|
||||
HandleStreamStopped(new StreamStopped(
|
||||
msg.NodeId, msg.Generation,
|
||||
new TimeoutException($"no telemetry event within {DialDeadlineFor().TotalSeconds:F0}s of dialing")));
|
||||
}
|
||||
|
||||
private TimeSpan DialDeadlineFor() => TimeSpan.FromSeconds(Math.Max(1, _options.CallTimeoutSeconds));
|
||||
|
||||
private void StartDialer(string nodeId)
|
||||
{
|
||||
var dialer = _dialers[nodeId];
|
||||
@@ -306,6 +338,8 @@ public sealed class TelemetryDialSupervisor : ReceiveActor, IWithTimers
|
||||
var cts = new CancellationTokenSource();
|
||||
dialer.Cts = cts;
|
||||
dialer.Connected = false;
|
||||
// One deadline per generation; a superseded tick is dropped by the generation guard in the handler.
|
||||
Timers.StartSingleTimer(DeadlineTimerKey(nodeId), new DialDeadline(nodeId, generation), DialDeadlineFor());
|
||||
|
||||
var self = Self;
|
||||
var target = dialer.Target;
|
||||
@@ -357,6 +391,7 @@ public sealed class TelemetryDialSupervisor : ReceiveActor, IWithTimers
|
||||
{
|
||||
dialer.Cancel();
|
||||
Timers.Cancel(ReconnectTimerKey(nodeId));
|
||||
Timers.Cancel(DeadlineTimerKey(nodeId));
|
||||
RecomputePill();
|
||||
}
|
||||
}
|
||||
@@ -433,6 +468,8 @@ public sealed class TelemetryDialSupervisor : ReceiveActor, IWithTimers
|
||||
|
||||
private static string ReconnectTimerKey(string nodeId) => $"telemetry-reconnect-{nodeId}";
|
||||
|
||||
private static string DeadlineTimerKey(string nodeId) => $"telemetry-dial-deadline-{nodeId}";
|
||||
|
||||
/// <summary>Per-node dialer bookkeeping. Mutated only on the actor thread.</summary>
|
||||
private sealed class NodeDialer(TelemetryDialTarget target)
|
||||
{
|
||||
@@ -496,4 +533,10 @@ public sealed class TelemetryDialSupervisor : ReceiveActor, IWithTimers
|
||||
/// <summary>Backoff timer tick: start a fresh dialer for the node.</summary>
|
||||
/// <param name="NodeId">The node id to reconnect.</param>
|
||||
public sealed record Reconnect(string NodeId);
|
||||
|
||||
/// <summary>Dial-establishment deadline tick (<c>TelemetryDial:CallTimeoutSeconds</c>); see
|
||||
/// <see cref="HandleDialDeadline"/>.</summary>
|
||||
/// <param name="NodeId">The node whose dial is being checked.</param>
|
||||
/// <param name="Generation">The dialer generation the deadline was armed for.</param>
|
||||
public sealed record DialDeadline(string NodeId, int Generation);
|
||||
}
|
||||
|
||||
@@ -9,6 +9,12 @@
|
||||
<ItemGroup>
|
||||
<FrameworkReference Include="Microsoft.AspNetCore.App"/>
|
||||
<PackageReference Include="Microsoft.AspNetCore.SignalR.Client"/>
|
||||
<!-- Surgical transitive pin — see the Microsoft.AspNetCore.SignalR.Common block in
|
||||
Directory.Packages.props (GHSA-334f-vvp4-7g6p on SignalR.Common 10.0.0). Inside AdminUI
|
||||
the shared framework already supplies it (hence NU1510), but the PackageReference flows
|
||||
to the non-Web consumers (Host.Tests, AdminUI.Tests, OpcUaServer.IntegrationTests) where
|
||||
SignalR.Client 10.0.0 would otherwise resolve the vulnerable 10.0.0. -->
|
||||
<PackageReference Include="Microsoft.AspNetCore.SignalR.Common" NoWarn="NU1510"/>
|
||||
<PackageReference Include="ZB.MOM.WW.Theme"/>
|
||||
<PackageReference Include="ZB.MOM.WW.Secrets.Ui"/>
|
||||
</ItemGroup>
|
||||
|
||||
@@ -45,8 +45,8 @@ public static class HistorianBackendRegistry
|
||||
new Dictionary<string, Func<ServerHistorianOptions, IConfiguration, IHistorianBackendProvider>>(StringComparer.OrdinalIgnoreCase)
|
||||
{
|
||||
[ServerHistorianOptions.GatewayBackendName] = (o, _) => new GatewayHistorianProvider(o),
|
||||
[SqlServerBackendName] = (o, c) => new SqlServerHistorianProvider(BindSqlServer(c), o.MaxTimeWeightedRawRows),
|
||||
[QuestDbBackendName] = (o, c) => new QuestDbHistorianProvider(BindQuestDb(c), o.MaxTimeWeightedRawRows),
|
||||
[SqlServerBackendName] = (o, c) => new SqlServerHistorianProvider(BindSqlServer(c), o.MaxTimeWeightedRawRows, o.EffectiveMaxRawValuesPerRead),
|
||||
[QuestDbBackendName] = (o, c) => new QuestDbHistorianProvider(BindQuestDb(c), o.MaxTimeWeightedRawRows, o.EffectiveMaxRawValuesPerRead),
|
||||
};
|
||||
|
||||
/// <summary>The registered backend names, for validation messages.</summary>
|
||||
|
||||
@@ -1,3 +1,5 @@
|
||||
using Opc.Ua;
|
||||
using Opc.Ua.Server;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.OpcUaServer;
|
||||
@@ -110,24 +112,62 @@ internal enum HistoryCursorKind
|
||||
/// <c>NumValuesPerNode</c> samples with a null continuation point — so paging is synthesised here,
|
||||
/// time-based:
|
||||
/// <list type="bullet">
|
||||
/// <item>A page that returns EXACTLY the requested cap (<c>NumValuesPerNode > 0</c>) MAY have
|
||||
/// more behind it ⇒ emit a continuation point.</item>
|
||||
/// <item>A short page (fewer than the cap) is the last page ⇒ no continuation point.</item>
|
||||
/// <item><c>NumValuesPerNode == 0</c> means "all values, no limit" (OPC UA Part 11) ⇒ never page;
|
||||
/// return everything in one shot.</item>
|
||||
/// <item>A page whose read returned the lookahead row past it MAY have more behind it ⇒ emit a continuation
|
||||
/// point (<see cref="IsFullPage"/> judges a read against what was asked for).</item>
|
||||
/// <item>A short read (no lookahead row) is the last page ⇒ no continuation point.</item>
|
||||
/// <item><c>NumValuesPerNode == 0</c> means "all values" (OPC UA Part 11) — but not "in one shot": the page is
|
||||
/// sized to the backend's <see cref="IHistorianDataSource.MaxRawValuesPerRead"/> by <see cref="RawPageLimit"/>
|
||||
/// (the server raw cap <c>ServerHistorian:MaxRawValuesPerRead</c>, default 10 000, and/or a strict gateway's
|
||||
/// learned ceiling; review R08:1.1, #736), and a full page carries a continuation point like any other. Only
|
||||
/// with no limit at all (<c>0</c>, the opt-out) is everything returned in one shot.</item>
|
||||
/// </list>
|
||||
/// All methods are static + pure so they unit-test without a server, a session, or the SDK.
|
||||
/// All paging methods are static + pure so they unit-test without a server, a session, or the SDK;
|
||||
/// <see cref="AdvertiseMaxReturnDataValues"/> is the one SDK-facing member.
|
||||
/// </summary>
|
||||
internal static class HistoryPaging
|
||||
{
|
||||
/// <summary>
|
||||
/// Decide whether a just-returned page is "full" and therefore MAY be followed by more data —
|
||||
/// the signal to emit a continuation point. A page is full when the client asked for a finite
|
||||
/// cap (<paramref name="numValuesPerNode"/> > 0) and the backend returned exactly that many
|
||||
/// samples. A short page (or an unlimited <c>0</c> request) is terminal.
|
||||
/// Advertise the server raw cap as <c>HistoryServerCapabilities/MaxReturnDataValues</c> (i=11273; Part 11 §5.4.2:
|
||||
/// "the maximum number of values that can be returned by the Server for each Node", 0 = no limit). The cap is
|
||||
/// the most values one HistoryRead-Raw page returns (<c>ServerHistorian:MaxRawValuesPerRead</c>), so a client can
|
||||
/// size its <c>NumValuesPerNode</c> and expect a continuation point past it. Idempotent; a re-sync with a
|
||||
/// different cap overwrites. Never throws: a missing diagnostics manager or node, or any SDK failure writing the
|
||||
/// property, leaves the SDK default (0) and returns <c>false</c> for the caller to log — HistoryRead itself still
|
||||
/// enforces the cap.
|
||||
/// </summary>
|
||||
/// <param name="returnedCount">The number of samples the backend returned for this page.</param>
|
||||
/// <param name="numValuesPerNode">The client's per-page cap; <c>0</c> means "no limit".</param>
|
||||
/// <param name="server">The running server.</param>
|
||||
/// <param name="maxRawValuesPerRead">The cap (<= 0 advertises 0 = no limit).</param>
|
||||
/// <returns><c>true</c> when the property was written.</returns>
|
||||
public static bool AdvertiseMaxReturnDataValues(IServerInternal? server, int maxRawValuesPerRead)
|
||||
{
|
||||
if (server?.DiagnosticsNodeManager is not DiagnosticsNodeManager diagnostics) return false;
|
||||
try
|
||||
{
|
||||
lock (diagnostics.Lock)
|
||||
{
|
||||
var capabilities = diagnostics.GetDefaultHistoryCapabilities();
|
||||
if (capabilities?.MaxReturnDataValues is not { } property) return false;
|
||||
property.Value = (uint)Math.Max(0, maxRawValuesPerRead);
|
||||
property.ClearChangeMasks(diagnostics.SystemContext, false);
|
||||
return true;
|
||||
}
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
return false; // advisory only: the caller logs; the cap is enforced by HistoryRead regardless
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Decide whether a just-returned read is "full" and therefore MAY be followed by more data —
|
||||
/// the signal to emit a continuation point. A read is full when it was issued with a finite request
|
||||
/// cap (<paramref name="numValuesPerNode"/> > 0 — the <c>RawPagePlan.RequestCap</c>: page + boundary ties +
|
||||
/// lookahead, which under a backend limit or the server raw cap is always finite, uncapped client reads included)
|
||||
/// and the backend returned at least that many samples. A short read is terminal; so is a read issued with a
|
||||
/// request cap of <c>0</c>, which only happens with no limit at all (one shot of the whole window).
|
||||
/// </summary>
|
||||
/// <param name="returnedCount">The number of samples the backend returned for this read.</param>
|
||||
/// <param name="numValuesPerNode">The request cap the read was issued with; <c>0</c> means "no limit".</param>
|
||||
/// <returns><c>true</c> when a continuation point should be emitted; otherwise <c>false</c>.</returns>
|
||||
public static bool IsFullPage(int returnedCount, uint numValuesPerNode) =>
|
||||
numValuesPerNode > 0 && returnedCount >= numValuesPerNode;
|
||||
|
||||
@@ -11,17 +11,22 @@ internal readonly record struct RawPagePlan(int Limit, uint PageCap, uint Reques
|
||||
|
||||
/// <summary>
|
||||
/// sizes a HistoryRead-Raw page to what the backend can return in one read
|
||||
/// (<see cref="IHistorianDataSource.MaxRawValuesPerRead"/> = L — a strict HistorianGateway's learned row ceiling, less
|
||||
/// its boundary-row allowance). With a limit the read — page P + boundary ties k + the lookahead row — is at most L,
|
||||
/// so P = min(want, L − k − 1) (all values: P = L − k − 1); a full page carries a continuation point like any other, as
|
||||
/// Part 11 allows fewer values than <c>NumValuesPerNode</c> with one. Previously a cap above a strict gateway's ceiling
|
||||
/// (or an uncapped read of a window holding more) failed <c>BadTooManyOperations</c>.
|
||||
/// (<see cref="IHistorianDataSource.MaxRawValuesPerRead"/> = L — the server raw cap
|
||||
/// <c>ServerHistorian:MaxRawValuesPerRead</c>, default 10 000, which every backend reports (review R08:1.1, #736),
|
||||
/// and/or a strict HistorianGateway's learned row ceiling less its boundary-row allowance, whichever is lower). With
|
||||
/// a limit the read — page P + boundary ties k + the lookahead row — is at most L, so P = min(want, L − k − 1) (all
|
||||
/// values: P = L − k − 1, i.e. a first page of 9 999 at the default cap); a full page carries a continuation point like
|
||||
/// any other, as Part 11 allows fewer values than <c>NumValuesPerNode</c> with one. Previously a cap above a strict
|
||||
/// gateway's ceiling (or an uncapped read of a window holding more) failed <c>BadTooManyOperations</c>, and before
|
||||
/// #736 an uncapped read on a backend without a ceiling read the whole window in one shot.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <para>
|
||||
/// <b>Never a silent truncation.</b> The backend still answers a read in full or refuses it; only the server's page is
|
||||
/// smaller, and a page is judged full against what was asked for. A read the backend cannot serve at all (a tie
|
||||
/// cluster larger than one read) stays <c>BadTooManyOperations</c>.
|
||||
/// cluster larger than one read) stays <c>BadTooManyOperations</c>. The backends enforce the same cap themselves
|
||||
/// (a read asking for more than L, or for everything, is refused when the window holds more than L rows), so this
|
||||
/// planner is what keeps the server's own reads inside it: with L > 0 no read it plans ever asks for 0 or more than L.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// <b>One re-read, planned again.</b> A refused read (<see cref="HistoryReadLimitExceededException"/>) is re-planned and
|
||||
|
||||
@@ -0,0 +1,73 @@
|
||||
using System.Collections.Concurrent;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Runtime.Drivers;
|
||||
|
||||
/// <summary>The last health snapshot a driver child published, as kept by <see cref="ChildHealthLedger"/>.</summary>
|
||||
/// <param name="State">The driver's reported state.</param>
|
||||
/// <param name="LastSuccessfulReadUtc">When the driver last read successfully, if ever.</param>
|
||||
/// <param name="LastError">The driver's last error, if any.</param>
|
||||
/// <param name="HostStatuses">Per-host connectivity for a multi-host driver, or null when the driver has none.</param>
|
||||
/// <param name="PublishedUtc">When the snapshot was published — the child's dedup means this is the last CHANGE.</param>
|
||||
public sealed record ChildHealthRecord(
|
||||
DriverState State,
|
||||
DateTime? LastSuccessfulReadUtc,
|
||||
string? LastError,
|
||||
IReadOnlyList<HostConnectivityStatus>? HostStatuses,
|
||||
DateTime PublishedUtc);
|
||||
|
||||
/// <summary>
|
||||
/// An <see cref="IDriverHealthPublisher"/> decorator that remembers the last snapshot per driver instance
|
||||
/// and forwards every publish to the real publisher. <see cref="DriverHostActor"/> wraps the publisher it
|
||||
/// hands its children in one of these so <c>GetDiagnostics</c> can answer from the children's own health
|
||||
/// (state, host counts, last change) instead of a placeholder — the children publish on their own actor
|
||||
/// threads, hence the concurrent map.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// Deliberately NOT a message to the host: the children already publish through this seam on every
|
||||
/// change, so a parallel <c>Tell</c> would double every health transition's traffic for one consumer.
|
||||
/// Entries are removed by the host when it stops a child; a late publish from a stopping child may re-add
|
||||
/// one, which the host filters against its live child set when it answers.
|
||||
/// </remarks>
|
||||
public sealed class ChildHealthLedger : IDriverHealthPublisher
|
||||
{
|
||||
private readonly IDriverHealthPublisher _inner;
|
||||
private readonly ConcurrentDictionary<string, ChildHealthRecord> _last = new(StringComparer.Ordinal);
|
||||
|
||||
/// <summary>Wraps <paramref name="inner"/>.</summary>
|
||||
/// <param name="inner">The publisher every snapshot is forwarded to.</param>
|
||||
public ChildHealthLedger(IDriverHealthPublisher inner)
|
||||
{
|
||||
ArgumentNullException.ThrowIfNull(inner);
|
||||
_inner = inner;
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
public void Publish(
|
||||
string clusterId,
|
||||
string driverInstanceId,
|
||||
DriverHealth health,
|
||||
int errorCount5Min,
|
||||
DateTime? rediscoveryNeededUtc = null,
|
||||
string? rediscoveryReason = null,
|
||||
IReadOnlyList<HostConnectivityStatus>? hostStatuses = null,
|
||||
SkippedTagReport? skippedTags = null,
|
||||
IReadOnlyDictionary<string, string>? diagnostics = null)
|
||||
{
|
||||
_last[driverInstanceId] = new ChildHealthRecord(
|
||||
health.State, health.LastSuccessfulRead, health.LastError, hostStatuses, DateTime.UtcNow);
|
||||
_inner.Publish(
|
||||
clusterId, driverInstanceId, health, errorCount5Min, rediscoveryNeededUtc, rediscoveryReason,
|
||||
hostStatuses, skippedTags, diagnostics);
|
||||
}
|
||||
|
||||
/// <summary>The last snapshot published for <paramref name="driverInstanceId"/>, or null if none yet.</summary>
|
||||
/// <param name="driverInstanceId">The driver instance.</param>
|
||||
/// <returns>The record, or null.</returns>
|
||||
public ChildHealthRecord? TryGet(string driverInstanceId) =>
|
||||
_last.TryGetValue(driverInstanceId, out var record) ? record : null;
|
||||
|
||||
/// <summary>Forgets <paramref name="driverInstanceId"/>'s snapshot (the child was stopped).</summary>
|
||||
/// <param name="driverInstanceId">The driver instance.</param>
|
||||
public void Forget(string driverInstanceId) => _last.TryRemove(driverInstanceId, out _);
|
||||
}
|
||||
@@ -195,7 +195,9 @@ public sealed class DriverHostActor : ReceiveActor, IWithTimers, IWithUnboundedS
|
||||
private readonly IReadOnlySet<string> _localRoles;
|
||||
private readonly IActorRef? _dependencyMux;
|
||||
private readonly IActorRef? _opcUaPublishActor;
|
||||
private readonly IDriverHealthPublisher _healthPublisher;
|
||||
/// <summary>The publisher handed to every child — a <see cref="ChildHealthLedger"/> over the configured one, so
|
||||
/// <see cref="HandleGetDiagnostics"/> answers from the children's own last-published health.</summary>
|
||||
private readonly ChildHealthLedger _healthPublisher;
|
||||
private readonly IVirtualTagEvaluator _virtualTagEvaluator;
|
||||
private readonly IHistoryWriter _historyWriter;
|
||||
private readonly IActorRef? _virtualTagHostOverride;
|
||||
@@ -594,6 +596,9 @@ public sealed class DriverHostActor : ReceiveActor, IWithTimers, IWithUnboundedS
|
||||
|
||||
private sealed record ChildEntry(IActorRef Actor, DriverInstanceSpec Spec, bool Stubbed)
|
||||
{
|
||||
/// <summary>When this child was spawned — the diagnostics' last-change time until it publishes health.</summary>
|
||||
public DateTime SpawnedUtc { get; } = DateTime.UtcNow;
|
||||
|
||||
// Convenience accessors for sites that don't need the full spec.
|
||||
/// <summary>Gets the driver type name from the child's spec.</summary>
|
||||
public string DriverType => Spec.DriverType;
|
||||
@@ -886,7 +891,7 @@ public sealed class DriverHostActor : ReceiveActor, IWithTimers, IWithUnboundedS
|
||||
_localRoles = localRoles ?? new HashSet<string>(StringComparer.Ordinal);
|
||||
_dependencyMux = dependencyMux;
|
||||
_opcUaPublishActor = opcUaPublishActor;
|
||||
_healthPublisher = healthPublisher ?? NullDriverHealthPublisher.Instance;
|
||||
_healthPublisher = new ChildHealthLedger(healthPublisher ?? NullDriverHealthPublisher.Instance);
|
||||
_virtualTagEvaluator = virtualTagEvaluator ?? NullVirtualTagEvaluator.Instance;
|
||||
_historyWriter = historyWriter ?? NullHistoryWriter.Instance;
|
||||
_virtualTagHostOverride = virtualTagHostOverride;
|
||||
@@ -2489,6 +2494,24 @@ public sealed class DriverHostActor : ReceiveActor, IWithTimers, IWithUnboundedS
|
||||
// A child connectivity transition while the host is Stale has no live address space to annotate — drop
|
||||
// it (the post-recovery rebuild re-materialises conditions, and the child re-announces on its next entry).
|
||||
Receive<DriverInstanceActor.ConnectivityChanged>(_ => { });
|
||||
// Likewise a child's value / alarm burst: Stale is entered from Bootstrap's catch before any child is
|
||||
// spawned, so none should arrive — but the orphan-replay BeginDirectApply in that same try block has
|
||||
// already started a pipe-back before the catch can run, so "cannot happen" rests on ordering. Explicit
|
||||
// drops, so a burst that does land is a logged drop rather than an Unhandled dead-letter.
|
||||
Receive<DriverInstanceActor.AttributeValueBatchPublished>(m =>
|
||||
_log.Debug("DriverHost {Node}: dropping a {Count}-item value burst from {Id} while Stale (no address space)",
|
||||
_localNode, m.Items.Count, m.DriverInstanceId));
|
||||
Receive<DriverInstanceActor.AttributeAlarmPublished>(m =>
|
||||
_log.Debug("DriverHost {Node}: dropping a native alarm transition ({Cond}) from {Id} while Stale",
|
||||
_localNode, m.Args.ConditionId, m.DriverInstanceId));
|
||||
// A late artifact pipe-back from the apply that was in flight when the host fell Stale: that apply is
|
||||
// lost (the coordinator's deadline and the boot-time orphan replay recover it). Warning, not Debug —
|
||||
// an apply outcome is being discarded.
|
||||
Receive<ArtifactForApply>(m =>
|
||||
_log.Warning("DriverHost {Node}: dropping the artifact for {Id} (rev {Rev}) that arrived while Stale; the apply is abandoned",
|
||||
_localNode, m.DeploymentId, m.Revision));
|
||||
Receive<ApplyWedged>(m =>
|
||||
_log.Debug("DriverHost {Node}: late apply-wedge tick for {Id} while Stale; dropping", _localNode, m.DeploymentId));
|
||||
// Likewise the 03/S15 recovery audit: a timer armed before the host went Stale has nothing to report
|
||||
// on (no latch was set while Stale, and the rebuild re-establishes every node's status anyway).
|
||||
Receive<CommsRecoveryAudit>(_ => { });
|
||||
@@ -2496,16 +2519,16 @@ public sealed class DriverHostActor : ReceiveActor, IWithTimers, IWithUnboundedS
|
||||
Timers.StartPeriodicTimer("retry-db", RetryConfigDbConnection.Instance, ReconnectInterval);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Answers <see cref="GetDiagnostics"/> from the live child set and each child's last-published health
|
||||
/// (<see cref="ChildHealthLedger"/>). Used to be a placeholder — <c>Guid.Empty</c>, "Spawned", zero
|
||||
/// devices, "now" — that looked live in every behaviour and was read by nobody (02/U1); the AdminUI
|
||||
/// fleet-diagnostics page is its consumer.
|
||||
/// </summary>
|
||||
private void HandleGetDiagnostics(GetDiagnostics msg)
|
||||
{
|
||||
var drivers = _children
|
||||
.Select(kv => new DriverInstanceDiagnostics(
|
||||
DriverInstanceId: Guid.Empty,
|
||||
Name: kv.Key,
|
||||
State: kv.Value.Stubbed ? "Stubbed" : "Spawned",
|
||||
ConnectedDevices: 0,
|
||||
FaultedDevices: 0,
|
||||
LastChangeUtc: DateTime.UtcNow))
|
||||
.Select(kv => ToDiagnostics(kv.Key, kv.Value, _healthPublisher.TryGet(kv.Key)))
|
||||
.ToArray();
|
||||
var snapshot = new NodeDiagnosticsSnapshot(
|
||||
NodeId: _localNode,
|
||||
@@ -2516,6 +2539,39 @@ public sealed class DriverHostActor : ReceiveActor, IWithTimers, IWithUnboundedS
|
||||
Sender.Tell(snapshot);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// One child's diagnostics row. <c>Name</c> carries the string driver-instance id — the identity every
|
||||
/// other surface (/hosts, telemetry, the artifact) keys on — and <c>DriverInstanceId</c> the DB row Guid;
|
||||
/// the wire record has no slot for the authored display name. Device counts come from the driver's host
|
||||
/// statuses when it is an <c>IHostConnectivityProbe</c> (Running = connected; Stopped/Faulted = faulted;
|
||||
/// Unknown = neither); a single-host driver counts as one device, connected while it reports Healthy or
|
||||
/// Degraded and faulted while it reports Faulted. A child that has not published yet reports
|
||||
/// "Connecting" (or "Stubbed") with its spawn time as the last change.
|
||||
/// </summary>
|
||||
private static DriverInstanceDiagnostics ToDiagnostics(string driverInstanceId, ChildEntry entry, ChildHealthRecord? health)
|
||||
{
|
||||
var name = driverInstanceId;
|
||||
if (entry.Stubbed)
|
||||
return new DriverInstanceDiagnostics(entry.Spec.DriverInstanceRowId, name, "Stubbed", 0, 0, entry.SpawnedUtc);
|
||||
if (health is null)
|
||||
return new DriverInstanceDiagnostics(entry.Spec.DriverInstanceRowId, name, "Connecting", 0, 0, entry.SpawnedUtc);
|
||||
|
||||
int connected, faulted;
|
||||
if (health.HostStatuses is { Count: > 0 } hosts)
|
||||
{
|
||||
connected = hosts.Count(h => h.State == HostState.Running);
|
||||
faulted = hosts.Count(h => h.State is HostState.Stopped or HostState.Faulted);
|
||||
}
|
||||
else
|
||||
{
|
||||
connected = health.State is DriverState.Healthy or DriverState.Degraded ? 1 : 0;
|
||||
faulted = health.State == DriverState.Faulted ? 1 : 0;
|
||||
}
|
||||
|
||||
return new DriverInstanceDiagnostics(
|
||||
entry.Spec.DriverInstanceRowId, name, health.State.ToString(), connected, faulted, health.PublishedUtc);
|
||||
}
|
||||
|
||||
private void HandleDispatchFromSteady(DispatchDeployment msg)
|
||||
{
|
||||
// The short-circuit claims a CLEAN Applied, so it is only honest while the current revision's
|
||||
@@ -3771,6 +3827,12 @@ public sealed class DriverHostActor : ReceiveActor, IWithTimers, IWithUnboundedS
|
||||
// id lifts it (the tracker via _invokerFactory.Create, the hub via Readmit).
|
||||
_invokerFactory.Release(driverInstanceId);
|
||||
_telemetryHub?.Evict(driverInstanceId);
|
||||
// The reprovision rate-limit stamp belongs to the incarnation history that just ended. Kept, it grew the
|
||||
// map by one entry per id ever reprovisioned-then-removed AND made a later re-add of the same id inherit a
|
||||
// backoff it never earned (its first crash was deferred as a "crash loop").
|
||||
_lastReprovisionUtc.Remove(driverInstanceId);
|
||||
Timers.Cancel(ReprovisionTimerKey(driverInstanceId));
|
||||
_healthPublisher.Forget(driverInstanceId);
|
||||
_log.Info("DriverHost {Node}: stopped driver child {Id}", _localNode, driverInstanceId);
|
||||
}
|
||||
|
||||
@@ -3821,6 +3883,8 @@ public sealed class DriverHostActor : ReceiveActor, IWithTimers, IWithUnboundedS
|
||||
StopDependencyAdapter(msg.DriverInstanceId);
|
||||
Context.Stop(entry.Actor);
|
||||
_children.Remove(msg.DriverInstanceId);
|
||||
// The old incarnation's health must not read as the new one's until it publishes its own.
|
||||
_healthPublisher.Forget(msg.DriverInstanceId);
|
||||
|
||||
// Respawn from the same spec the last reconcile used — preserves RowId, Name, ClusterId.
|
||||
SpawnChild(entry.Spec);
|
||||
|
||||
@@ -1,3 +1,4 @@
|
||||
using System.Diagnostics;
|
||||
using Akka.Actor;
|
||||
using Akka.Event;
|
||||
using ZB.MOM.WW.OtOpcUa.Cluster;
|
||||
@@ -184,6 +185,52 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
/// </remarks>
|
||||
public static readonly TimeSpan DefaultCommsLossTimeout = TimeSpan.FromSeconds(90);
|
||||
|
||||
/// <summary>
|
||||
/// Bound on the driver's <see cref="IDriver.ShutdownAsync"/> (and its dispose) when the child stops or
|
||||
/// restarts, and on the teardown that precedes every reconnect attempt. <c>PostStop</c> runs on a
|
||||
/// dispatcher thread and blocks on it, so a driver whose shutdown waits on a dead socket / COM proxy used
|
||||
/// to pin that thread for as long as the wait took — a few such stops starved the default dispatcher and
|
||||
/// wedged <c>CoordinatedShutdown</c> and the host's own restart cascade. A shutdown that overruns is
|
||||
/// abandoned (logged), never awaited further.
|
||||
/// </summary>
|
||||
public static readonly TimeSpan DefaultShutdownTimeout = TimeSpan.FromSeconds(5);
|
||||
|
||||
/// <summary>
|
||||
/// Default cap on the writes this actor runs against its driver at once. Writes run OFF the mailbox
|
||||
/// (a <c>ReceiveAsync</c> used to suspend it for the whole device round-trip, so writes serialised and
|
||||
/// every data change queued behind them — the second of two operator writes to a slow device missed the
|
||||
/// host's 8 s Ask and was reverted although the device took it). The cap keeps a burst from flooding a
|
||||
/// device with concurrent commands; writes beyond it queue in order and start as slots free.
|
||||
/// </summary>
|
||||
public const int DefaultMaxWritesInFlight = 4;
|
||||
|
||||
/// <summary>
|
||||
/// How long a queued write may wait for a slot before it is failed <c>BadTimeout</c> instead of being
|
||||
/// written. The host's write Ask is 8 s: a write older than that has already been reported as a timeout
|
||||
/// (and its node reverted) upstream, so writing it late would push a stale value to the device.
|
||||
/// </summary>
|
||||
public static readonly TimeSpan DefaultQueuedWriteBudget = TimeSpan.FromSeconds(8);
|
||||
|
||||
/// <summary>
|
||||
/// Pessimistic bound on one <see cref="IDriver.InitializeAsync"/> attempt. The invoker's tier timeout is
|
||||
/// token-only (optimistic), so a driver whose initialise ignores its token would otherwise hold the
|
||||
/// single-flight gate forever and wedge the reconnect loop. 2× the longest tier (Tier C: 15 s).
|
||||
/// </summary>
|
||||
public static readonly TimeSpan DefaultInitializeTimeout = TimeSpan.FromSeconds(30);
|
||||
|
||||
/// <summary>
|
||||
/// Pessimistic bound on one write round-trip, on top of the 5 s token-based write cap. A driver whose
|
||||
/// <see cref="IWritable.WriteAsync"/> ignores its token would otherwise hold its slot AND its tag forever,
|
||||
/// piling every later write to that tag up in the queue. 2× the write cap.
|
||||
/// </summary>
|
||||
public static readonly TimeSpan DefaultWriteTimeout = TimeSpan.FromSeconds(10);
|
||||
|
||||
/// <summary>Self-sent by a write task once it has replied, releasing its slot and its tag.</summary>
|
||||
/// <param name="TagId">The tag the write held.</param>
|
||||
/// <param name="Incarnation">The actor incarnation that launched it — a late completion from a previous
|
||||
/// incarnation (after a supervision restart) must not free the new incarnation's slot or tag.</param>
|
||||
private sealed record WriteCompleted(string TagId, int Incarnation);
|
||||
|
||||
private readonly IDriver _driver;
|
||||
|
||||
/// <summary>Phase 6.1 resilience seam: every guarded driver-capability call this actor makes is
|
||||
@@ -204,6 +251,47 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
/// <summary>Comms-loss watchdog threshold; <see cref="TimeSpan.Zero"/> or negative disables it.</summary>
|
||||
private readonly TimeSpan _commsLossTimeout;
|
||||
|
||||
/// <summary>Bound on the driver shutdown / dispose; see <see cref="DefaultShutdownTimeout"/>.</summary>
|
||||
private readonly TimeSpan _shutdownTimeout;
|
||||
|
||||
/// <summary>Cap on concurrent writes; see <see cref="DefaultMaxWritesInFlight"/>.</summary>
|
||||
private readonly int _maxWritesInFlight;
|
||||
|
||||
/// <summary>Writes currently inside the driver. Actor-thread only (incremented on launch, decremented on
|
||||
/// the self-sent <see cref="WriteCompleted"/>).</summary>
|
||||
private int _writesInFlight;
|
||||
|
||||
/// <summary>Writes waiting for a slot (or for their tag), in arrival order, stamped with arrival time.
|
||||
/// Failed fast on every exit from <c>Connected</c>, so a queued write never reaches a driver that is
|
||||
/// reconnecting; failed <c>BadTimeout</c> at dequeue once older than <see cref="_queuedWriteBudget"/>.</summary>
|
||||
private readonly LinkedList<(WriteAttribute Write, IActorRef ReplyTo, DateTime EnqueuedUtc)> _pendingWrites = new();
|
||||
|
||||
/// <summary>Tags with a write currently inside the driver. A second write to the same tag waits in the
|
||||
/// queue behind it — two concurrent writes v1, v2 to one tag could otherwise land as v1.</summary>
|
||||
private readonly HashSet<string> _tagsInFlight = new(StringComparer.Ordinal);
|
||||
|
||||
/// <summary>See <see cref="DefaultQueuedWriteBudget"/>.</summary>
|
||||
private readonly TimeSpan _queuedWriteBudget;
|
||||
|
||||
/// <summary>See <see cref="DefaultInitializeTimeout"/>.</summary>
|
||||
private readonly TimeSpan _initializeTimeout;
|
||||
|
||||
/// <summary>See <see cref="DefaultWriteTimeout"/>.</summary>
|
||||
private readonly TimeSpan _writeTimeout;
|
||||
|
||||
/// <summary>This actor object's identity for its own off-mailbox completions (drawn from the process-wide
|
||||
/// generation source, so it is unique across supervision restarts of the same child).</summary>
|
||||
private readonly int _incarnation;
|
||||
|
||||
/// <summary>
|
||||
/// Set by <see cref="PreRestart"/> so the <see cref="PostStop"/> it triggers skips the dispose. A
|
||||
/// supervision restart recreates the actor object around the SAME <see cref="IDriver"/> (the Props closure
|
||||
/// captured it) and the host then re-initialises that driver — disposing it here would hand the new
|
||||
/// incarnation a dead object. Only a real stop (deploy removal, operator Restart, respawn on config change,
|
||||
/// host shutdown) disposes.
|
||||
/// </summary>
|
||||
private bool _restarting;
|
||||
|
||||
/// <summary>When the actor last entered <c>Connected</c>. The comms-loss watchdog's baseline for a
|
||||
/// driver that has never reported a successful read, so "connected but never read anything" is
|
||||
/// measurable rather than indefinitely undefined.</summary>
|
||||
@@ -218,6 +306,26 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
/// on the actor thread, so no lock is needed.</summary>
|
||||
private int _initGeneration;
|
||||
|
||||
/// <summary>Process-wide source of attempt generations. A supervision restart recreates the actor object
|
||||
/// (fresh fields) while a prior incarnation's attempt may still be running on the same driver; a per-actor
|
||||
/// counter restarting at 0 would let that late result collide with the new incarnation's first attempt.</summary>
|
||||
private static int s_initGenerationSource;
|
||||
|
||||
/// <summary>
|
||||
/// True while an <see cref="InitializeAsync"/> attempt is running (set when it is launched, cleared by its
|
||||
/// piped <see cref="InitializeSucceeded"/>/<see cref="InitializeFailed"/>). The <c>Reconnecting</c> retry
|
||||
/// timer fires on its cadence regardless of whether the previous attempt finished, and the generation
|
||||
/// token only discards an older attempt's RESULT — so with an Initialize bound longer than the cadence
|
||||
/// (Tier C: 15 s vs. 10 s) attempt N+1's teardown ran while attempt N was still inside the driver: the
|
||||
/// dispose-before-overwrite race the drivers' rule file forbids, once per overlap. A tick that lands while
|
||||
/// an attempt is in flight is skipped; the next tick after the result retries. Actor-thread only.
|
||||
/// </summary>
|
||||
private bool _initInFlight;
|
||||
|
||||
/// <summary>Cancellation for the in-flight attempt, so <see cref="PostStop"/> can cancel it before the
|
||||
/// shutdown rather than let it race the teardown on a restart.</summary>
|
||||
private CancellationTokenSource? _initCts;
|
||||
|
||||
/// <summary>
|
||||
/// Timestamps of recent Faulted-state transitions; used to compute the 5-minute error count.
|
||||
/// No lock needed — every read/write site runs inside an Akka message handler, which is
|
||||
@@ -307,6 +415,17 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
/// <param name="commsLossTimeout">Optional comms-loss watchdog threshold; defaults to
|
||||
/// <see cref="DefaultCommsLossTimeout"/>. <see cref="TimeSpan.Zero"/> disables the watchdog — used by
|
||||
/// tests that need a Connected driver to stay Connected while reporting non-Healthy.</param>
|
||||
/// <param name="shutdownTimeout">Optional bound on the driver's shutdown / dispose on stop and on the
|
||||
/// pre-reconnect teardown; defaults to <see cref="DefaultShutdownTimeout"/>. Exists so a test can prove a
|
||||
/// hung shutdown is abandoned without waiting 5 s.</param>
|
||||
/// <param name="maxWritesInFlight">Optional cap on concurrent writes against the driver; defaults to
|
||||
/// <see cref="DefaultMaxWritesInFlight"/>. Writes beyond it queue in arrival order.</param>
|
||||
/// <param name="queuedWriteBudget">Optional bound on how long a queued write may wait before it is failed
|
||||
/// <c>BadTimeout</c>; defaults to <see cref="DefaultQueuedWriteBudget"/>.</param>
|
||||
/// <param name="initializeTimeout">Optional pessimistic bound on one initialise attempt; defaults to
|
||||
/// <see cref="DefaultInitializeTimeout"/>.</param>
|
||||
/// <param name="writeTimeout">Optional pessimistic bound on one write round-trip; defaults to
|
||||
/// <see cref="DefaultWriteTimeout"/>.</param>
|
||||
/// <returns>A <see cref="Akka.Actor.Props"/> instance configured to create the wrapped <see cref="DriverInstanceActor"/>.</returns>
|
||||
public static Props Props(
|
||||
IDriver driver,
|
||||
@@ -316,7 +435,12 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
string? clusterId = null,
|
||||
IDriverCapabilityInvoker? invoker = null,
|
||||
TimeSpan? healthPollInterval = null,
|
||||
TimeSpan? commsLossTimeout = null) =>
|
||||
TimeSpan? commsLossTimeout = null,
|
||||
TimeSpan? shutdownTimeout = null,
|
||||
int? maxWritesInFlight = null,
|
||||
TimeSpan? queuedWriteBudget = null,
|
||||
TimeSpan? initializeTimeout = null,
|
||||
TimeSpan? writeTimeout = null) =>
|
||||
Akka.Actor.Props.Create(() => new DriverInstanceActor(
|
||||
driver,
|
||||
reconnectInterval ?? DefaultReconnectInterval,
|
||||
@@ -325,7 +449,12 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
clusterId ?? string.Empty,
|
||||
invoker,
|
||||
healthPollInterval,
|
||||
commsLossTimeout));
|
||||
commsLossTimeout,
|
||||
shutdownTimeout,
|
||||
maxWritesInFlight,
|
||||
queuedWriteBudget,
|
||||
initializeTimeout,
|
||||
writeTimeout));
|
||||
|
||||
/// <summary>
|
||||
/// Returns true when the driver should boot in DEV-STUB mode based on host platform and
|
||||
@@ -362,6 +491,16 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
/// subscription reconcile; defaults to <see cref="HealthPollInterval"/> when null.</param>
|
||||
/// <param name="commsLossTimeout">Comms-loss watchdog threshold; defaults to
|
||||
/// <see cref="DefaultCommsLossTimeout"/> when null, and is disabled when zero or negative.</param>
|
||||
/// <param name="shutdownTimeout">Bound on the driver's shutdown / dispose; defaults to
|
||||
/// <see cref="DefaultShutdownTimeout"/> when null.</param>
|
||||
/// <param name="maxWritesInFlight">Cap on concurrent writes; defaults to
|
||||
/// <see cref="DefaultMaxWritesInFlight"/> when null or non-positive.</param>
|
||||
/// <param name="queuedWriteBudget">Bound on a queued write's wait; defaults to
|
||||
/// <see cref="DefaultQueuedWriteBudget"/> when null or non-positive.</param>
|
||||
/// <param name="initializeTimeout">Pessimistic bound on one initialise attempt; defaults to
|
||||
/// <see cref="DefaultInitializeTimeout"/> when null or non-positive.</param>
|
||||
/// <param name="writeTimeout">Pessimistic bound on one write round-trip; defaults to
|
||||
/// <see cref="DefaultWriteTimeout"/> when null or non-positive.</param>
|
||||
public DriverInstanceActor(
|
||||
IDriver driver,
|
||||
TimeSpan reconnectInterval,
|
||||
@@ -370,8 +509,18 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
string? clusterId = null,
|
||||
IDriverCapabilityInvoker? invoker = null,
|
||||
TimeSpan? healthPollInterval = null,
|
||||
TimeSpan? commsLossTimeout = null)
|
||||
TimeSpan? commsLossTimeout = null,
|
||||
TimeSpan? shutdownTimeout = null,
|
||||
int? maxWritesInFlight = null,
|
||||
TimeSpan? queuedWriteBudget = null,
|
||||
TimeSpan? initializeTimeout = null,
|
||||
TimeSpan? writeTimeout = null)
|
||||
{
|
||||
_writeTimeout = writeTimeout is { } wt && wt > TimeSpan.Zero ? wt : DefaultWriteTimeout;
|
||||
_incarnation = Interlocked.Increment(ref s_initGenerationSource);
|
||||
_maxWritesInFlight = maxWritesInFlight is > 0 ? maxWritesInFlight.Value : DefaultMaxWritesInFlight;
|
||||
_queuedWriteBudget = queuedWriteBudget is { } qb && qb > TimeSpan.Zero ? qb : DefaultQueuedWriteBudget;
|
||||
_initializeTimeout = initializeTimeout is { } it && it > TimeSpan.Zero ? it : DefaultInitializeTimeout;
|
||||
_driver = driver;
|
||||
_invoker = invoker ?? NullDriverCapabilityInvoker.Instance;
|
||||
_driverInstanceId = driver.DriverInstanceId;
|
||||
@@ -380,6 +529,7 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
_reconnectInterval = reconnectInterval;
|
||||
_healthPollInterval = healthPollInterval ?? HealthPollInterval;
|
||||
_commsLossTimeout = commsLossTimeout ?? DefaultCommsLossTimeout;
|
||||
_shutdownTimeout = shutdownTimeout is { } bound && bound > TimeSpan.Zero ? bound : DefaultShutdownTimeout;
|
||||
OtOpcUaTelemetry.DriverInstanceLifecycle.Add(1,
|
||||
new KeyValuePair<string, object?>("event", startStubbed ? "spawn_stub" : "spawn"),
|
||||
new KeyValuePair<string, object?>("driver_type", driver.DriverType));
|
||||
@@ -421,6 +571,18 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
Context.Parent.Tell(new ReprovisionRequested(_driverInstanceId, reason.GetType().Name));
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Flags the restart before the base implementation runs <see cref="PostStop"/>, so that PostStop
|
||||
/// shuts the driver down (the host re-initialises it on <see cref="ReprovisionRequested"/>) but does
|
||||
/// NOT dispose it — see <see cref="_restarting"/>.
|
||||
/// </summary>
|
||||
/// <inheritdoc />
|
||||
protected override void PreRestart(Exception reason, object message)
|
||||
{
|
||||
_restarting = true;
|
||||
base.PreRestart(reason, message);
|
||||
}
|
||||
|
||||
private void Stubbed()
|
||||
{
|
||||
// Stubbed drivers accept the standard message contracts but return deterministic
|
||||
@@ -448,6 +610,8 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
// "write timeout". Synchronous Receive: Sender.Tell on the actor thread is safe.
|
||||
Receive<WriteAttribute>(_ =>
|
||||
Sender.Tell(new WriteAttributeResult(false, "driver not connected")));
|
||||
// A write launched while Connected can finish after the transition out of it; its slot still frees.
|
||||
Receive<WriteCompleted>(OnWriteCompleted);
|
||||
// An ack arriving while still connecting can't reach the upstream alarm system; drop it (the ack is
|
||||
// fire-and-forget — no reply to surface — and the OPC UA condition state already committed locally).
|
||||
Receive<RouteAlarmAck>(_ =>
|
||||
@@ -455,6 +619,7 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
Receive<InitializeSucceeded>(msg =>
|
||||
{
|
||||
if (msg.Generation != _initGeneration) return;
|
||||
CompleteInitAttempt();
|
||||
_log.Info("DriverInstance {Id}: connected", _driverInstanceId);
|
||||
Become(Connected);
|
||||
PublishHealthSnapshot();
|
||||
@@ -465,6 +630,7 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
Receive<InitializeFailed>(msg =>
|
||||
{
|
||||
if (msg.Generation != _initGeneration) return;
|
||||
CompleteInitAttempt();
|
||||
_log.Warning("DriverInstance {Id}: initialize failed: {Reason}", _driverInstanceId, msg.Reason);
|
||||
RecordFault();
|
||||
Become(Reconnecting);
|
||||
@@ -514,10 +680,14 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
{
|
||||
_log.Info("DriverInstance {Id}: ForceReconnect requested by admin; re-entering Reconnecting", _driverInstanceId);
|
||||
DetachSubscription();
|
||||
FailQueuedWrites("driver not connected");
|
||||
Become(Reconnecting);
|
||||
PublishHealthSnapshot();
|
||||
});
|
||||
ReceiveAsync<WriteAttribute>(HandleWriteAsync);
|
||||
// Synchronous Receive: the device call runs off the mailbox (see StartOrQueueWrite), so data changes
|
||||
// and further writes are never head-of-line blocked behind a slow device.
|
||||
Receive<WriteAttribute>(msg => StartOrQueueWrite(msg, Sender));
|
||||
Receive<WriteCompleted>(OnWriteCompleted);
|
||||
ReceiveAsync<RouteAlarmAck>(HandleAcknowledgeAsync);
|
||||
ReceiveAsync<Subscribe>(HandleSubscribeAsync);
|
||||
ReceiveAsync<Unsubscribe>(_ => UnsubscribeAsync());
|
||||
@@ -745,6 +915,7 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
// timeout on an inbound write to a transiently-down driver). Synchronous Receive.
|
||||
Receive<WriteAttribute>(_ =>
|
||||
Sender.Tell(new WriteAttributeResult(false, "driver not connected")));
|
||||
Receive<WriteCompleted>(OnWriteCompleted);
|
||||
// An ack arriving while reconnecting can't reach the upstream alarm system; drop it (fire-and-forget,
|
||||
// no reply — the OPC UA condition state already committed locally on the Part 9 ack).
|
||||
Receive<RouteAlarmAck>(_ =>
|
||||
@@ -752,6 +923,7 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
Receive<InitializeSucceeded>(msg =>
|
||||
{
|
||||
if (msg.Generation != _initGeneration) return;
|
||||
CompleteInitAttempt();
|
||||
Timers.Cancel("retry-connect");
|
||||
_log.Info("DriverInstance {Id}: reconnected", _driverInstanceId);
|
||||
Become(Connected);
|
||||
@@ -760,9 +932,13 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
AttachAlarmSource();
|
||||
SubscribeDesiredAlarms();
|
||||
});
|
||||
// A failure here is a no-op regardless of generation — the retry timer keeps trying the
|
||||
// current config; only a (generation-matched) InitializeSucceeded transitions state.
|
||||
Receive<InitializeFailed>(_ => { /* keep retrying via timer */ });
|
||||
// A failure here changes no state — the retry timer keeps trying the current config; only a
|
||||
// (generation-matched) InitializeSucceeded transitions. It DOES release the single-flight gate, or
|
||||
// no later tick could ever retry.
|
||||
Receive<InitializeFailed>(msg =>
|
||||
{
|
||||
if (msg.Generation == _initGeneration) CompleteInitAttempt();
|
||||
});
|
||||
Receive<SetDesiredSubscriptions>(StoreDesiredSubscriptions);
|
||||
Receive<ForceReconnect>(_ => { /* already reconnecting — no-op */ });
|
||||
Receive<ConnectionLossRaised>(IgnoreConnectionLoss);
|
||||
@@ -807,12 +983,28 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
private void InitializeAsync(string driverConfigJson, bool teardownFirst = false)
|
||||
{
|
||||
_currentConfigJson = driverConfigJson;
|
||||
var generation = ++_initGeneration;
|
||||
if (_initInFlight)
|
||||
{
|
||||
// SINGLE-FLIGHT (02/H2). The previous attempt is still inside the driver; starting another would run
|
||||
// its teardown against the transport that attempt is building. Skip — the next tick after the
|
||||
// result retries, and a config handed over meanwhile is already stored for it.
|
||||
_log.Debug("DriverInstance {Id}: initialise attempt {Gen} still in flight; skipping this one",
|
||||
_driverInstanceId, _initGeneration);
|
||||
return;
|
||||
}
|
||||
|
||||
_initInFlight = true;
|
||||
var generation = Interlocked.Increment(ref s_initGenerationSource);
|
||||
_initGeneration = generation;
|
||||
var initCts = new CancellationTokenSource();
|
||||
_initCts = initCts;
|
||||
var self = Self;
|
||||
var log = _log;
|
||||
var driverInstanceId = _driverInstanceId;
|
||||
var driver = _driver;
|
||||
var invoker = _invoker;
|
||||
var shutdownTimeout = _shutdownTimeout;
|
||||
var initializeTimeout = _initializeTimeout;
|
||||
_ = Task.Run(async () =>
|
||||
{
|
||||
try
|
||||
@@ -823,7 +1015,16 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
{
|
||||
// Deliberately UNWRAPPED: teardown is best-effort cleanup of an already-dead
|
||||
// transport — a shutdown failure must not count toward the Initialize breaker.
|
||||
await driver.ShutdownAsync(CancellationToken.None);
|
||||
// BOUNDED: a teardown wedged on the dead transport must not hold the retry loop
|
||||
// (and this thread) for longer than the bound; it is abandoned and the init proceeds.
|
||||
using var teardownCts = new CancellationTokenSource(shutdownTimeout);
|
||||
await driver.ShutdownAsync(teardownCts.Token).WaitAsync(shutdownTimeout);
|
||||
}
|
||||
catch (TimeoutException)
|
||||
{
|
||||
log.Warning(
|
||||
"DriverInstance {Id}: ShutdownAsync did not complete within {Bound} before a reconnect " +
|
||||
"attempt; abandoning it and initialising anyway", driverInstanceId, shutdownTimeout);
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
@@ -841,33 +1042,103 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
// attempt with BrokenCircuitException, which lands in the catch below exactly like a
|
||||
// real connect failure: InitializeFailed → keep retrying on the timer. The 15 s break
|
||||
// window is shorter than two 10 s timer ticks, so recovery costs at most one extra tick.
|
||||
await invoker.ExecuteAsync(
|
||||
// The outer token is this attempt's own: PostStop cancels it so a stop/restart does not run its
|
||||
// shutdown underneath an attempt still inside the driver.
|
||||
// PESSIMISTIC bound on top of the invoker's token-only timeout: a driver that ignores its token
|
||||
// would otherwise hold the single-flight gate forever. An overrun is abandoned (the task keeps
|
||||
// running, its eventual outcome is observed and discarded), reported as a failure so the retry
|
||||
// loop continues, and its late Tell is dropped by the generation guard anyway.
|
||||
var attempt = invoker.ExecuteAsync(
|
||||
DriverCapability.Initialize,
|
||||
driverInstanceId,
|
||||
async ct => await driver.InitializeAsync(driverConfigJson, ct),
|
||||
CancellationToken.None);
|
||||
initCts.Token).AsTask();
|
||||
try
|
||||
{
|
||||
await attempt.WaitAsync(initializeTimeout);
|
||||
}
|
||||
catch (TimeoutException)
|
||||
{
|
||||
log.Warning(
|
||||
"DriverInstance {Id}: initialise attempt {Gen} did not complete within {Bound} (the driver ignored " +
|
||||
"its cancellation token); attempt abandoned, the retry loop continues",
|
||||
driverInstanceId, generation, initializeTimeout);
|
||||
try { initCts.Cancel(); } catch (ObjectDisposedException) { }
|
||||
_ = attempt.ContinueWith(t => _ = t.Exception, TaskContinuationOptions.OnlyOnFaulted);
|
||||
self.Tell(new InitializeFailed($"initialise did not complete within {initializeTimeout}", generation));
|
||||
return;
|
||||
}
|
||||
self.Tell(new InitializeSucceeded(generation));
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
self.Tell(new InitializeFailed(ex.Message, generation));
|
||||
}
|
||||
finally
|
||||
{
|
||||
// The CTS outlives an abandoned attempt (it may still be inside the driver); dispose only once
|
||||
// nothing can cancel it any more — the actor nulls _initCts when it honours the result.
|
||||
if (!initCts.IsCancellationRequested) initCts.Dispose();
|
||||
}
|
||||
});
|
||||
}
|
||||
|
||||
private async Task HandleWriteAsync(WriteAttribute msg)
|
||||
/// <summary>Releases the single-flight gate once the in-flight attempt's result has been honoured.</summary>
|
||||
private void CompleteInitAttempt()
|
||||
{
|
||||
_initInFlight = false;
|
||||
_initCts = null;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Launches a write against the driver off the mailbox, or queues it when
|
||||
/// <see cref="_maxWritesInFlight"/> writes are already inside the driver. Runs on the actor thread; the
|
||||
/// only actor state it touches is the in-flight count and the queue. The device round-trip itself
|
||||
/// (<see cref="RunWriteAsync"/>) replies to the captured sender from the thread pool and then
|
||||
/// self-sends <see cref="WriteCompleted"/> to free its slot.
|
||||
/// </summary>
|
||||
private void StartOrQueueWrite(WriteAttribute msg, IActorRef replyTo)
|
||||
{
|
||||
var replyTo = Sender;
|
||||
if (_driver is not IWritable writable)
|
||||
{
|
||||
replyTo.Tell(new WriteAttributeResult(false, "Driver does not implement IWritable"));
|
||||
return;
|
||||
}
|
||||
|
||||
if (_writesInFlight >= _maxWritesInFlight || _tagsInFlight.Contains(msg.TagId))
|
||||
{
|
||||
_pendingWrites.AddLast((msg, replyTo, DateTime.UtcNow));
|
||||
return;
|
||||
}
|
||||
|
||||
LaunchWrite(writable, msg, replyTo);
|
||||
}
|
||||
|
||||
private void LaunchWrite(IWritable writable, WriteAttribute msg, IActorRef replyTo)
|
||||
{
|
||||
_writesInFlight++;
|
||||
_tagsInFlight.Add(msg.TagId);
|
||||
// Everything the task needs is captured HERE, on the actor thread — ResolveHost reads the driver,
|
||||
// and Self must not be touched off-context.
|
||||
var self = Self;
|
||||
var hostKey = ResolveHost(msg.TagId);
|
||||
var invoker = _invoker;
|
||||
_ = RunWriteAsync(writable, invoker, hostKey, msg, replyTo, self, _writeTimeout, _incarnation, _log);
|
||||
}
|
||||
|
||||
private static async Task RunWriteAsync(
|
||||
IWritable writable, IDriverCapabilityInvoker invoker, string hostKey,
|
||||
WriteAttribute msg, IActorRef replyTo, IActorRef self, TimeSpan writeTimeout, int incarnation,
|
||||
ILoggingAdapter log)
|
||||
{
|
||||
// Off the actor context from here on: the first await yields, and nothing below reads actor state.
|
||||
await Task.Yield();
|
||||
var request = new[] { new WriteRequest(msg.TagId, msg.Value) };
|
||||
// Bound the write so a hung backend can't pin this actor forever — retry stays
|
||||
// off by default, but a stalled call still needs an answer.
|
||||
using var cts = new CancellationTokenSource(TimeSpan.FromSeconds(5));
|
||||
// Bound the write so a hung backend can't hold a slot forever — retry stays
|
||||
// off by default, but a stalled call still needs an answer. Disposed below, except when the write is
|
||||
// abandoned (the orphan may still be holding the token).
|
||||
var cts = new CancellationTokenSource(TimeSpan.FromSeconds(5));
|
||||
var abandoned = false;
|
||||
try
|
||||
{
|
||||
// Route through the resilience invoker (Write pipeline: timeout, per-host breaker). Writes
|
||||
@@ -877,11 +1148,31 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
// therefore authoritative regardless of any configured Write retry. Per-tag opt-in to retries via
|
||||
// WriteIdempotentAttribute is the unshipped forward path (see WriteIdempotentAttribute). The outer
|
||||
// cts is retained as a hard backstop above the (typically tighter) tier timeout.
|
||||
var results = await _invoker.ExecuteWriteAsync(
|
||||
ResolveHost(msg.TagId),
|
||||
// PESSIMISTIC bound on top of the token-based cap: a driver that ignores its token would otherwise
|
||||
// hold the slot and the tag forever, piling every later write to that tag up in the queue.
|
||||
var attempt = invoker.ExecuteWriteAsync(
|
||||
hostKey,
|
||||
isIdempotent: false,
|
||||
async ct => await writable.WriteAsync(request, ct),
|
||||
cts.Token);
|
||||
cts.Token).AsTask();
|
||||
IReadOnlyList<WriteResult> results;
|
||||
try
|
||||
{
|
||||
results = await attempt.WaitAsync(writeTimeout);
|
||||
}
|
||||
catch (TimeoutException)
|
||||
{
|
||||
abandoned = true;
|
||||
log.Warning(
|
||||
"DriverInstance write of {Tag} did not complete within {Bound} (the driver ignored its cancellation " +
|
||||
"token); abandoned — its slot and tag are released, its eventual outcome is discarded",
|
||||
msg.TagId, writeTimeout);
|
||||
try { cts.Cancel(); } catch (ObjectDisposedException) { }
|
||||
_ = attempt.ContinueWith(t => _ = t.Exception, TaskContinuationOptions.OnlyOnFaulted);
|
||||
replyTo.Tell(new WriteAttributeResult(false,
|
||||
$"StatusCode=0x800A0000 (BadTimeout: write did not complete within {writeTimeout.TotalSeconds:F0}s)"));
|
||||
return;
|
||||
}
|
||||
if (results is { Count: 1 } && IsGoodStatus(results[0].StatusCode))
|
||||
{
|
||||
replyTo.Tell(new WriteAttributeResult(true, null));
|
||||
@@ -898,6 +1189,62 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
{
|
||||
replyTo.Tell(new WriteAttributeResult(false, ex.Message));
|
||||
}
|
||||
finally
|
||||
{
|
||||
if (!abandoned) cts.Dispose();
|
||||
self.Tell(new WriteCompleted(msg.TagId, incarnation));
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Frees the write's slot and tag and drains the queue: the oldest entries whose tag is free are
|
||||
/// launched (in arrival order) while slots remain; entries older than the budget are failed instead. A
|
||||
/// completion stamped with another incarnation (a write launched before a supervision restart) is ignored —
|
||||
/// it never held a slot or tag of THIS incarnation.</summary>
|
||||
private void OnWriteCompleted(WriteCompleted msg)
|
||||
{
|
||||
if (msg.Incarnation != _incarnation) return;
|
||||
if (_writesInFlight > 0) _writesInFlight--;
|
||||
_tagsInFlight.Remove(msg.TagId);
|
||||
DrainWriteQueue();
|
||||
}
|
||||
|
||||
private void DrainWriteQueue()
|
||||
{
|
||||
if (_driver is not IWritable writable) return;
|
||||
var now = DateTime.UtcNow;
|
||||
var node = _pendingWrites.First;
|
||||
while (node is not null && _writesInFlight < _maxWritesInFlight)
|
||||
{
|
||||
var next = node.Next;
|
||||
var (write, replyTo, enqueuedUtc) = node.Value;
|
||||
if (now - enqueuedUtc > _queuedWriteBudget)
|
||||
{
|
||||
// Already reported as a timeout upstream (the host's Ask is the budget) and the node reverted —
|
||||
// writing it now would push a stale value to the device. BadTimeout, never written.
|
||||
_pendingWrites.Remove(node);
|
||||
replyTo.Tell(new WriteAttributeResult(false,
|
||||
$"StatusCode=0x800A0000 (BadTimeout: queued for {(now - enqueuedUtc).TotalSeconds:F1}s, over the {_queuedWriteBudget.TotalSeconds:F0}s write budget)"));
|
||||
}
|
||||
else if (!_tagsInFlight.Contains(write.TagId))
|
||||
{
|
||||
_pendingWrites.Remove(node);
|
||||
LaunchWrite(writable, write, replyTo);
|
||||
}
|
||||
|
||||
node = next;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Replies to every queued write with <paramref name="reason"/>; called on each exit from
|
||||
/// <c>Connected</c>. In-flight writes are left to finish — they already hold the device and reply with its
|
||||
/// real outcome.</summary>
|
||||
private void FailQueuedWrites(string reason)
|
||||
{
|
||||
while (_pendingWrites.First is { } node)
|
||||
{
|
||||
_pendingWrites.RemoveFirst();
|
||||
node.Value.ReplyTo.Tell(new WriteAttributeResult(false, reason));
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
@@ -1145,6 +1492,7 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
{
|
||||
_log.Warning("DriverInstance {Id}: disconnect observed ({Reason}); reconnecting", _driverInstanceId, reason);
|
||||
DetachSubscription();
|
||||
FailQueuedWrites("driver not connected");
|
||||
RecordFault();
|
||||
Become(Reconnecting);
|
||||
PublishHealthSnapshot();
|
||||
@@ -1542,15 +1890,91 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
}
|
||||
|
||||
DetachSubscription();
|
||||
FailQueuedWrites("driver stopped");
|
||||
// MUST happen: the IDriver instance can outlive this actor (the host respawns a child around the
|
||||
// same driver object), so a missing unsubscribe accumulates a handler per respawn holding a dead Self.
|
||||
DetachRediscoverySource();
|
||||
DetachHostStatusSource();
|
||||
DetachConnectionLossSource();
|
||||
try { _driver.ShutdownAsync(CancellationToken.None).GetAwaiter().GetResult(); }
|
||||
catch (Exception ex) { _log.Warning(ex, "DriverInstance {Id}: ShutdownAsync threw on PostStop", _driverInstanceId); }
|
||||
|
||||
// An attempt still inside the driver is cancelled before the shutdown below runs underneath it (on a
|
||||
// restart the next incarnation re-initialises the same object). Best-effort: the task owns the CTS
|
||||
// and may have disposed it already.
|
||||
try { _initCts?.Cancel(); }
|
||||
catch (ObjectDisposedException) { /* the attempt already finished */ }
|
||||
|
||||
// BOUNDED by ONE shared budget across shutdown + dispose. PostStop runs on a dispatcher thread and this
|
||||
// blocks it, so an unbounded wait on a driver whose shutdown hangs against a dead socket / COM proxy pinned
|
||||
// that thread for the whole wait, and a few such stops starved the dispatcher. A shutdown that overruns is
|
||||
// abandoned, and the dispose gets whatever is left of the same budget (never a second full one).
|
||||
var budget = Stopwatch.StartNew();
|
||||
using (var cts = new CancellationTokenSource(_shutdownTimeout))
|
||||
{
|
||||
try { _driver.ShutdownAsync(cts.Token).WaitAsync(_shutdownTimeout).GetAwaiter().GetResult(); }
|
||||
catch (TimeoutException)
|
||||
{
|
||||
_log.Warning("DriverInstance {Id}: ShutdownAsync did not complete within {Bound} on PostStop; abandoning it",
|
||||
_driverInstanceId, _shutdownTimeout);
|
||||
}
|
||||
catch (Exception ex) { _log.Warning(ex, "DriverInstance {Id}: ShutdownAsync threw on PostStop", _driverInstanceId); }
|
||||
}
|
||||
|
||||
// Dispose ONLY on a real stop. A supervision restart (PreRestart → this PostStop) re-uses the same driver
|
||||
// object for the next incarnation, which the host re-initialises. Everything else that stops a child —
|
||||
// deploy removal, operator Restart, respawn on a config change, host shutdown — is final, and the driver
|
||||
// is never touched again: before this, nothing in the runtime ever disposed an IDriver, so a Calculation
|
||||
// driver's compiled-script AssemblyLoadContexts and an OpcUaClient driver's LoggerFactory / gate / CTS
|
||||
// leaked once per respawn (02/L1). Bounded like the shutdown, and runs even after a timed-out shutdown —
|
||||
// leaking the object is strictly worse than disposing one whose shutdown is still wedged.
|
||||
if (!_restarting)
|
||||
{
|
||||
var remaining = _shutdownTimeout - budget.Elapsed;
|
||||
DisposeDriver(remaining > MinDisposeBudget ? remaining : MinDisposeBudget);
|
||||
}
|
||||
|
||||
OtOpcUaTelemetry.DriverInstanceLifecycle.Add(1,
|
||||
new KeyValuePair<string, object?>("event", "stop"),
|
||||
new KeyValuePair<string, object?>("driver_type", _driver.DriverType));
|
||||
}
|
||||
|
||||
/// <summary>Floor on the dispose's share of the PostStop budget once a timed-out shutdown has used it up —
|
||||
/// enough for an idempotent dispose to run, not enough to double the stop's thread time.</summary>
|
||||
private static readonly TimeSpan MinDisposeBudget = TimeSpan.FromMilliseconds(250);
|
||||
|
||||
/// <summary>Final teardown of the wrapped driver: <see cref="IAsyncDisposable"/> preferred, else
|
||||
/// <see cref="IDisposable"/>, never both. A driver implementing neither needs nothing here. Runs even after
|
||||
/// a timed-out shutdown, so a driver's dispose must be safe CONCURRENTLY with its own still-running
|
||||
/// <see cref="IDriver.ShutdownAsync"/>.</summary>
|
||||
/// <param name="bound">The remaining PostStop budget available to an async dispose.</param>
|
||||
private void DisposeDriver(TimeSpan bound)
|
||||
{
|
||||
try
|
||||
{
|
||||
switch (_driver)
|
||||
{
|
||||
case IAsyncDisposable asyncDisposable:
|
||||
asyncDisposable.DisposeAsync().AsTask().WaitAsync(bound).GetAwaiter().GetResult();
|
||||
break;
|
||||
case IDisposable disposable:
|
||||
disposable.Dispose();
|
||||
break;
|
||||
default:
|
||||
return;
|
||||
}
|
||||
|
||||
_log.Info("DriverInstance {Id}: disposed {Type} driver on stop", _driverInstanceId, _driver.DriverType);
|
||||
OtOpcUaTelemetry.DriverInstanceLifecycle.Add(1,
|
||||
new KeyValuePair<string, object?>("event", "dispose"),
|
||||
new KeyValuePair<string, object?>("driver_type", _driver.DriverType));
|
||||
}
|
||||
catch (TimeoutException)
|
||||
{
|
||||
_log.Warning("DriverInstance {Id}: DisposeAsync did not complete within {Bound} on PostStop; abandoning it",
|
||||
_driverInstanceId, bound);
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
_log.Warning(ex, "DriverInstance {Id}: disposing the driver threw on PostStop", _driverInstanceId);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -7,21 +7,37 @@ namespace ZB.MOM.WW.OtOpcUa.Runtime.Health;
|
||||
|
||||
/// <summary>
|
||||
/// Single-flight cached health probe against the ConfigDb. Reads cached state via
|
||||
/// <c>Ask<DbHealthStatus></c>; a single SELECT 1 runs at most every <c>RefreshInterval</c>.
|
||||
/// <c>Ask<DbHealthStatus></c>; a single SELECT runs at most every <c>RefreshInterval</c>.
|
||||
/// Consumed by both the host's <c>/health/ready</c> endpoint and
|
||||
/// <c>RedundancyStateActor</c>'s stale calc.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// The probe runs OFF the mailbox (a thread-pool task that pipes its outcome back), with a bounded
|
||||
/// command timeout. It used to run synchronously on the actor thread, relying on SqlClient's implicit
|
||||
/// 15 s connect / 30 s command timeouts — so a hanging SQL Server pinned a dispatcher thread for up to
|
||||
/// 30 s per tick, later ticks queued behind it, and the cached <see cref="GetStatus"/> answer was
|
||||
/// unreachable for exactly as long as the database was. Single-flight: a tick that lands while a probe
|
||||
/// is still running is skipped rather than stacked.
|
||||
/// </remarks>
|
||||
public sealed class DbHealthProbeActor : ReceiveActor, IWithTimers
|
||||
{
|
||||
public static readonly TimeSpan RefreshInterval = TimeSpan.FromSeconds(5);
|
||||
|
||||
/// <summary>Bound on the probe's SQL command, relational providers only (the in-memory provider the
|
||||
/// actor tests run against has no command timeout).</summary>
|
||||
public static readonly TimeSpan CommandTimeout = TimeSpan.FromSeconds(2);
|
||||
|
||||
public sealed class GetStatus { public static readonly GetStatus Instance = new(); private GetStatus() { } }
|
||||
public sealed record DbHealthStatus(bool Reachable, DateTime AsOfUtc, string? LastError);
|
||||
public sealed class Tick { public static readonly Tick Instance = new(); private Tick() { } }
|
||||
|
||||
/// <summary>Piped back by the off-thread probe with its outcome.</summary>
|
||||
private sealed record ProbeCompleted(DbHealthStatus Status);
|
||||
|
||||
private readonly IDbContextFactory<OtOpcUaConfigDbContext> _dbFactory;
|
||||
private readonly ILoggingAdapter _log = Context.GetLogger();
|
||||
private DbHealthStatus _last = new(false, DateTime.MinValue, "not probed yet");
|
||||
private bool _probeInFlight;
|
||||
|
||||
/// <summary>Gets or sets the timer scheduler for periodic health probes.</summary>
|
||||
public ITimerScheduler Timers { get; set; } = null!;
|
||||
@@ -38,28 +54,54 @@ public sealed class DbHealthProbeActor : ReceiveActor, IWithTimers
|
||||
{
|
||||
_dbFactory = dbFactory;
|
||||
Receive<GetStatus>(_ => Sender.Tell(_last));
|
||||
Receive<Tick>(_ => RunProbe());
|
||||
Receive<Tick>(_ => StartProbe());
|
||||
Receive<ProbeCompleted>(msg =>
|
||||
{
|
||||
_probeInFlight = false;
|
||||
_last = msg.Status;
|
||||
if (!msg.Status.Reachable)
|
||||
_log.Warning("DbHealthProbe: probe failed: {Error}", msg.Status.LastError);
|
||||
});
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
protected override void PreStart()
|
||||
{
|
||||
RunProbe();
|
||||
StartProbe();
|
||||
Timers.StartPeriodicTimer("probe", Tick.Instance, RefreshInterval);
|
||||
}
|
||||
|
||||
private void RunProbe()
|
||||
private void StartProbe()
|
||||
{
|
||||
if (_probeInFlight)
|
||||
{
|
||||
_log.Debug("DbHealthProbe: previous probe still running; skipping this tick");
|
||||
return;
|
||||
}
|
||||
|
||||
_probeInFlight = true;
|
||||
var factory = _dbFactory;
|
||||
// Never touches actor state; the outcome comes back as a message.
|
||||
Task.Run(() => Probe(factory)).PipeTo(
|
||||
Self,
|
||||
success: status => new ProbeCompleted(status),
|
||||
failure: ex => new ProbeCompleted(new DbHealthStatus(false, DateTime.UtcNow, ex.Message)));
|
||||
}
|
||||
|
||||
private static DbHealthStatus Probe(IDbContextFactory<OtOpcUaConfigDbContext> factory)
|
||||
{
|
||||
try
|
||||
{
|
||||
using var db = _dbFactory.CreateDbContext();
|
||||
using var db = factory.CreateDbContext();
|
||||
// Local to this lease — the pool resets it on return (see DriverHostActor.LoadArtifactBlob).
|
||||
if (db.Database.IsRelational())
|
||||
db.Database.SetCommandTimeout(CommandTimeout);
|
||||
_ = db.Deployments.AsNoTracking().Take(1).ToList();
|
||||
_last = new DbHealthStatus(true, DateTime.UtcNow, null);
|
||||
return new DbHealthStatus(true, DateTime.UtcNow, null);
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
_last = new DbHealthStatus(false, DateTime.UtcNow, ex.Message);
|
||||
_log.Warning(ex, "DbHealthProbe: probe failed");
|
||||
return new DbHealthStatus(false, DateTime.UtcNow, ex.Message);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -154,6 +154,42 @@ public sealed class ServerHistorianOptions
|
||||
/// </summary>
|
||||
public int MaxTimeWeightedRawRows { get; init; } = 1_000_000;
|
||||
|
||||
/// <summary>The default of <see cref="MaxRawValuesPerRead"/>: 10 000 values per raw page / backend read.</summary>
|
||||
public const int DefaultMaxRawValuesPerRead = 10_000;
|
||||
|
||||
/// <summary>
|
||||
/// The smallest usable <see cref="MaxRawValuesPerRead"/>: a resumed page's read must carry at least one value, the
|
||||
/// boundary tie it re-reads and trims, AND the lookahead row that tells the server more data follows. At 2 a resumed
|
||||
/// page has no room at all and every value costs an empty page with a continuation point (the #692 defect, re-created
|
||||
/// by configuration), so 1 and 2 are raised to 3 (<see cref="EffectiveMaxRawValuesPerRead"/>).
|
||||
/// </summary>
|
||||
public const int MinMaxRawValuesPerRead = 3;
|
||||
|
||||
/// <summary>
|
||||
/// Every backend: the most raw values the server returns on ONE HistoryRead-Raw page, and the most rows one
|
||||
/// backend raw read may materialise — the server's own row ceiling (review R08:1.1, #736). A client's
|
||||
/// <c>NumValuesPerNode = 0</c> ("all values") no longer reads a whole window into memory: it is served as pages of at
|
||||
/// most this many values, each with a continuation point (Part 11 allows fewer values than requested with one), through
|
||||
/// the same tie-safe paging a capped read uses (<c>RawPageLimit</c>: page + boundary ties + lookahead ≤ cap, so a first
|
||||
/// page holds cap − 1 values). A <c>NumValuesPerNode</c> above it is paged at it too. Advertised as
|
||||
/// <c>HistoryServerCapabilities/MaxReturnDataValues</c>. The backends' own <c>TOP</c> / <c>LIMIT</c> / <c>max_values</c>
|
||||
/// are bounded by it independently: a raw read asking for more than this (or for everything) reads at most cap + 1 rows
|
||||
/// and is REFUSED (<c>BadTooManyOperations</c>) when the window holds more — never answered truncated — so a caller that
|
||||
/// bypasses the node manager's paging cannot bypass the bound. On the Gateway backend a strict gateway's learned row
|
||||
/// ceiling (less its boundary-row allowance) still applies when lower. The tie-cluster bound of a resumed page is also
|
||||
/// at most cap − 1 (as under a gateway ceiling; <see cref="MaxTieClusterOverfetch"/> above that is inert), and a
|
||||
/// page whose boundary tie cluster is that large steps past it with one empty page. Default 10 000. Non-positive =
|
||||
/// unbounded, the pre-#736 behaviour (a <see cref="Validate"/> warning); below <see cref="MinMaxRawValuesPerRead"/>
|
||||
/// (3) is raised to it.
|
||||
/// </summary>
|
||||
public int MaxRawValuesPerRead { get; init; } = DefaultMaxRawValuesPerRead;
|
||||
|
||||
/// <summary>
|
||||
/// <see cref="MaxRawValuesPerRead"/> as the backends and the node manager apply it: <c>0</c> (unbounded) when
|
||||
/// non-positive, otherwise at least <see cref="MinMaxRawValuesPerRead"/>. The one place the rule lives.
|
||||
/// </summary>
|
||||
public int EffectiveMaxRawValuesPerRead => MaxRawValuesPerRead <= 0 ? 0 : Math.Max(MinMaxRawValuesPerRead, MaxRawValuesPerRead);
|
||||
|
||||
/// <summary>
|
||||
/// how far into the future an OPC UA HistoryUpdate (Insert / Replace / Update) item's
|
||||
/// <c>SourceTimestamp</c> may lie, measured from the server clock. An item beyond <c>now + skew</c> is refused
|
||||
@@ -208,6 +244,10 @@ public sealed class ServerHistorianOptions
|
||||
warnings.Add($"ServerHistorian:MaxConcurrentHistoryReadBatches is {MaxConcurrentHistoryReadBatches} — must be > 0; the process-wide HistoryRead batch limiter is disabled.");
|
||||
if (MaxTimeWeightedRawRows <= 0)
|
||||
warnings.Add($"ServerHistorian:MaxTimeWeightedRawRows is {MaxTimeWeightedRawRows} — must be > 0; time-weighted aggregate reads on the SqlServer/QuestDb backends stream an unbounded number of raw samples.");
|
||||
if (MaxRawValuesPerRead <= 0)
|
||||
warnings.Add($"ServerHistorian:MaxRawValuesPerRead is {MaxRawValuesPerRead} — must be > 0; HistoryRead-Raw pages and backend raw reads are unbounded, so a client asking for a whole window (NumValuesPerNode = 0) materialises every sample in memory.");
|
||||
else if (MaxRawValuesPerRead < MinMaxRawValuesPerRead)
|
||||
warnings.Add($"ServerHistorian:MaxRawValuesPerRead is {MaxRawValuesPerRead} — must be at least {MinMaxRawValuesPerRead} (a value, its boundary tie and the lookahead row); treated as {MinMaxRawValuesPerRead}.");
|
||||
if (EventReadHorizon < TimeSpan.Zero)
|
||||
warnings.Add($"ServerHistorian:EventReadHorizon is {EventReadHorizon} — negative is treated as no horizon (00:00:00); HistoryReadEvents reads every window in full.");
|
||||
if (HistoryReadDeadline <= TimeSpan.Zero)
|
||||
|
||||
@@ -27,7 +27,27 @@ namespace ZB.MOM.WW.OtOpcUa.Runtime.Telemetry;
|
||||
/// </remarks>
|
||||
public sealed class TelemetryLocalHub : ITelemetryLocalHub
|
||||
{
|
||||
/// <summary>
|
||||
/// How long an eviction tombstone (see <see cref="_evicted"/>) is kept. It only has to outlive the
|
||||
/// removed child's last late write — an in-flight capability call that completes after
|
||||
/// <c>StopChild</c>, bounded by the longest capability timeout (seconds) plus the child's own stop —
|
||||
/// so ten minutes is a wide margin. Without a sweep a driver removed for good kept its id forever.
|
||||
/// </summary>
|
||||
public static readonly TimeSpan EvictionTombstoneTtl = TimeSpan.FromMinutes(10);
|
||||
|
||||
private readonly object _gate = new();
|
||||
private readonly TimeProvider _time;
|
||||
|
||||
/// <summary>Initializes a hub on the system clock.</summary>
|
||||
public TelemetryLocalHub() : this(TimeProvider.System) { }
|
||||
|
||||
/// <summary>Initializes a hub on <paramref name="time"/> — the tombstone-sweep test seam.</summary>
|
||||
/// <param name="time">The clock the eviction tombstones are stamped and swept by.</param>
|
||||
public TelemetryLocalHub(TimeProvider time)
|
||||
{
|
||||
ArgumentNullException.ThrowIfNull(time);
|
||||
_time = time;
|
||||
}
|
||||
|
||||
// Plain Dictionary, NOT ConcurrentDictionary: every access is already under _gate, and
|
||||
// ConcurrentDictionary.Values would materialize a fresh List (and take its own internal lock) on
|
||||
@@ -42,9 +62,10 @@ public sealed class TelemetryLocalHub : ITelemetryLocalHub
|
||||
private readonly ConcurrentDictionary<string, TelemetryItem.Health> _healthCache = new();
|
||||
private readonly ConcurrentDictionary<(string InstanceId, string HostName), TelemetryItem.Resilience> _resilienceCache = new();
|
||||
|
||||
// Instances evicted and not since readmitted. Their late Health/Resilience items are dropped, so a
|
||||
// removed driver's still-stopping child cannot re-prime the cache it was just evicted from. Under _gate.
|
||||
private readonly HashSet<string> _evicted = new(StringComparer.Ordinal);
|
||||
// Instances evicted and not since readmitted, stamped with the eviction time. Their late Health/Resilience
|
||||
// items are dropped, so a removed driver's still-stopping child cannot re-prime the cache it was just
|
||||
// evicted from. Swept past EvictionTombstoneTtl on the next Evict (never on the Emit hot path). Under _gate.
|
||||
private readonly Dictionary<string, DateTimeOffset> _evicted = new(StringComparer.Ordinal);
|
||||
|
||||
/// <inheritdoc />
|
||||
public void Emit(TelemetryItem item)
|
||||
@@ -55,9 +76,9 @@ public sealed class TelemetryLocalHub : ITelemetryLocalHub
|
||||
{
|
||||
switch (item)
|
||||
{
|
||||
case TelemetryItem.Health h when _evicted.Contains(h.E.DriverInstanceId):
|
||||
case TelemetryItem.Health h when _evicted.ContainsKey(h.E.DriverInstanceId):
|
||||
return;
|
||||
case TelemetryItem.Resilience r when _evicted.Contains(r.E.DriverInstanceId):
|
||||
case TelemetryItem.Resilience r when _evicted.ContainsKey(r.E.DriverInstanceId):
|
||||
return;
|
||||
case TelemetryItem.Health h:
|
||||
_healthCache[h.E.DriverInstanceId] = h;
|
||||
@@ -80,7 +101,9 @@ public sealed class TelemetryLocalHub : ITelemetryLocalHub
|
||||
|
||||
lock (_gate)
|
||||
{
|
||||
_evicted.Add(driverInstanceId);
|
||||
var now = _time.GetUtcNow();
|
||||
SweepExpiredTombstones(now);
|
||||
_evicted[driverInstanceId] = now;
|
||||
_healthCache.TryRemove(driverInstanceId, out _);
|
||||
foreach (var key in _resilienceCache.Keys)
|
||||
if (string.Equals(key.InstanceId, driverInstanceId, StringComparison.Ordinal))
|
||||
@@ -97,6 +120,24 @@ public sealed class TelemetryLocalHub : ITelemetryLocalHub
|
||||
_evicted.Remove(driverInstanceId);
|
||||
}
|
||||
|
||||
/// <summary>Drops tombstones older than <see cref="EvictionTombstoneTtl"/>. Called under <see cref="_gate"/>
|
||||
/// from <see cref="Evict"/> only — the set is bounded by distinct removed ids, so a linear pass per
|
||||
/// eviction is cheap, and Emit never pays for it.</summary>
|
||||
private void SweepExpiredTombstones(DateTimeOffset now)
|
||||
{
|
||||
if (_evicted.Count == 0) return;
|
||||
List<string>? expired = null;
|
||||
foreach (var (id, evictedAt) in _evicted)
|
||||
{
|
||||
if (now - evictedAt >= EvictionTombstoneTtl)
|
||||
(expired ??= new List<string>()).Add(id);
|
||||
}
|
||||
|
||||
if (expired is null) return;
|
||||
foreach (var id in expired)
|
||||
_evicted.Remove(id);
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
public ITelemetrySubscription Subscribe(int boundedCapacity)
|
||||
{
|
||||
|
||||
Reference in New Issue
Block a user